Troxler 5850v2 Operation And Instruction Manual

Page 1
Manual of Operation and Instruction
Model 5850v2
Gyratory Compactor
NOTE
Before using the Model 5850v2 Gyratory Compactor, carefully read this manual. It is especially important to understand the Safety Warnings on page 1–1. Keep this manual in a safe place that is always easily accessible during the use of the Model 5850v2.
Troxler Electronic Laboratories, Inc.
3008 E. Cornwallis Road P.O. Box 12057
Research Triangle Park, NC 27709 U.S.A.
Phone: 1.877.TROXLER
Outside the U.S.A.: +1.919.549.8661
Fax: +1.919.549.0761
www.troxlerlabs.com
Page 2
ii
Troxler products are protected by U.S. and foreign patents.
Copyright 2009 – 2015
Troxler Electronic Laboratories, Inc.
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose without the express written permission of Troxler Electronic Laboratories, Inc.
Bindoff is a registered trademark of Chemical Solutions, Inc.
Magnalube-G is a registered trademark of Magnalube, Inc.
Superpave is a trademark of the Strategic Highway Research
Program.
PN 116901 October 2015 Edition 3.0
Page 3
Model 5850v2 iii
TROXLER SERVICE CENTERS
Troxler Corporate Headquarters
3008 E. Cornwallis Road P.O. Box 12057
Research Triangle Park, NC 27709
Phone: 1.877.TROXLER (1.877.876.9537)
Outside the U.S.A.: +1.919.549.8661
Fax: +1.919.549.0761
Web: www.troxlerlabs.com
Technical Support
Phone: 1.877.TROXLER (1.877.876.9537) E-mail: TroxTechSupport@troxlerlabs.com
NORTH CAROLINA SERVICE CENTER
3008 E. Cornwallis Road Research Triangle Park, NC 27709 Phone: +1.919.549.8661 Fax: +1.919.549.0761 TroxTechSupport@troxlerlabs.com
FLORIDA BRANCH OFFICE & SERVICE CENTER
2376 Forsyth Road Orlando, FL 32807 Phone: +1.407.681.4221 Fax: +1.407.681.3188 TroxTechSupport@troxlerlabs.com
MIDWESTERN BRANCH OFFICE & SERVICE CENTER
1430 Brook Drive Downers Grove, IL 60515 Phone: +1.630.261.9304 Fax: +1.630.261.9341 TroxTechSupport@troxlerlabs.com
WESTERN BRANCH OFFICE & SERVICE CENTER
11300 Sanders Drive, Suite 7 Rancho Cordova, CA 95742 Phone: +1.916.631.0234 Fax: +1.916.631.0541 TroxTechSupport@troxlerlabs.com
SOUTHWESTERN BRANCH OFFICE & SERVICE CENTER
2016 East Randol Mill Road Suite 406 Arlington, TX 76011 Phone: +1.817.275.0571 Fax: +1.817.275.8562 TroxTechSupport@troxlerlabs.com
TROXLER EUROPE & SERVICE CENTER
Troxler Electronics GmbH Gilchinger Strasse 33 D.82239 Alling nr. Munich, Germany Phone: ++ 49.8141.71063 Fax: ++49.8141.80731 troxler@t-online.de
TROXLER ELECTRONIC TECHNOLOGIES (ZHANGJIAGANG)
1F, Building G, No. 1 Guotai North Road ZJG, China, 215600 Phone: 0086.512.56793702 Fax: 0086.512.56793701 kjin@troxlerlabs.cn
NOTE
To locate an independent, Troxler-authorized service partner near you, call 1.877.TROXLER (1.877.876.9537).
Page 4
iv
ABOUT THIS MANUAL
The Model 5850v2 Manual of Operation and Instruction provides detailed information about the compactor. The manual includes product safety information, as well as instructions for the proper installation and use of the compactor.
This manual is organized as follows:
Chapter 1, Introduction to the Model 5850v2 – Provides
information on the safe use of the compactor; a brief overview of the compactor and its features; a list of parts and accessories; and instructions for unpacking and inspection.
Chapter 2, Setup and Operation – Describes the compactor
keypad, and provides instructions for setting up, starting, and operating the compactor.
Chapter 3, Setup Menu Provides a detailed description of the
options available from the compactor’s Setup menu.
Chapter 4, Calibration and Verification – Includes instructions
for calibrating the compactor and verifying its calibration.
Chapter 5, Special Functions Describes the functions available
from the compactor’s Special menu.
Appendix A, Troubleshooting and Service – Provides
maintenance and service information, as well as instructions on basic troubleshooting.
Appendix B, Menu Map Shows a map of the compactor’s Setup
menu.
Appendix C, Specifications – Contains the environmental,
performance, electrical, and mechanical specifications of the compactor.
Page 5
Model 5850v2 v
HOW TO USE THIS MANUAL
Congratulations on the purchase of the Model 5850v2 Gyratory Compactor.
The Model 5850v2 Manual of Operation and Instruction contains information on safely using this unit. Also included in this manual are safety warnings, basic parameter setup, system troubleshooting, and general maintenance.
Do not attempt to operate the Model 5850v2 before reading this manual and the safety warnings posted on the unit. Troxler stresses that the user is solely responsible for ensuring the safe use of the Model 5850v2. The manufacturer, its subsidiary, representatives, and distributors cannot assume responsibility for any mishaps, damage, or personal injury that may occur from failure to observe the safety warnings in this manual and posted on the unit.
Page 6
vi
CONVENTIONS USED IN THIS MANUAL
Throughout this manual, symbols and special formatting are used to reveal the purpose of the text as follows:
WARNING
Warnings indicate conditions or procedures that, if not followed correctly, may cause personal injury.
CAUTION
Cautions indicate conditions or procedures that, if not followed correctly, may cause equipment damage.
NOTE
Notes indicate important information that must be read to ensure proper operation.
KEY Angle brackets and a different typestyle indicate a
key or character (number or letter) to press on the
compactor keypad. For example, “Press START
means to press the key labeled START.
DISPLAY A different typestyle is used in text to indicate
information or messages displayed on the compactor.
DISPLAY- Typestyle and shading used to simulate the control panel display
11..
Numbers indicate a procedure with multiple steps.
Diamonds indicate a list of things needed (such as
equipment) or things to know.
Triangles indicate that more than one option is
available. Carefully select the option that applies.
Page 7
Model 5850v2 vii
TABLE OF CONTENTS
About This Manual .......................................................................... iv
CHAPTER 1 ................................................................................ 1–1
Safety Warnings ............................................................................ 1–1
Cautions and Warnings ................................................................. 1–3
Introduction ................................................................................... 1–4
Parts and Accessories.................................................................... 1–8
Inspection ...................................................................................... 1–9
Unpacking ................................................................................... 1–10
Site Selection .............................................................................. 1–11
Assembly .................................................................................... 1–12
CHAPTER 2 ................................................................................ 2–1
Control Panel ................................................................................ 2–2
Turning the System On ................................................................. 2–4
Compacting a Specimen ............................................................... 2–6
Cleaning and Lubricating.............................................................. 2–8
Preparing a Specimen ................................................................. 2–10
Compacting the Specimen .......................................................... 2–14
Removing the Sample from the Mold ......................................... 2–15
Cooling the Sample ..................................................................... 2–16
Shear Options & Performance Tests ........................................... 2–16
CHAPTER 3 ................................................................................ 3–1
Setup Menu ................................................................................... 3–2
View Settings ................................................................................ 3–3
Change Settings ............................................................................ 3–4
Home Position ............................................................................ 3–14
Calibration .................................................................................. 3–14
Special......................................................................................... 3–14
CHAPTER 4 ................................................................................ 4–1
Calibration Schedule ..................................................................... 4–2
Angle Verification ........................................................................ 4–3
Calibration .................................................................................... 4–5
CHAPTER 5 ................................................................................ 5–1
Special Menu ................................................................................ 5–2
Clock/Calendar ............................................................................. 5–3
Erase Records ............................................................................... 5–6
Reset Software .............................................................................. 5–7
Page 8
viii
APPENDIX A ............................................................................. A–1
Troubleshooting............................................................................ A–2
General Maintenance Schedule .................................................... A–4
Replacing the Batteries ................................................................. A–7
Cleaning the Cooling Fan ............................................................. A–8
Replacement Parts ........................................................................ A–8
Returning Parts for Service .......................................................... A–9
APPENDIX B .............................................................................. B–1
Menu Map Description ................................................................. B–2
APPENDIX C ............................................................................. C–1
Environmental Conditions ............................................................ C–2
Electrical Specifications ............................................................... C–3
Mechanical Specifications ............................................................ C–4
INDEX
WARRANTY
Page 9
Model 5850v2 ix
LIST OF FIGURES
Figure Title Page
Figure 1–1. Model 5850v2 Gyratory Compactor ......................... 1–7
Figure 1–2. Hydraulic Reservoir ................................................ 1–12
Figure 1–3. Proper Reservoir Fill Level ..................................... 1–13
Figure 1–4. Place a Funnel in Reservoir Fill Tube ..................... 1–13
Figure 2–1. Model 5850v2 Control Panel Layout ........................ 2–3
Figure 2–2. Compaction Chamber ................................................ 2–9
Figure 2–3. Loading the Mold .................................................... 2–12
Figure 3–1. Sample Height Versus Gyration Table .................... 3–13
Figure 4–1. Aligning the Internal Angle Device Probes ............... 4–3
Figure 4–2. Puck Centered on Lower Carriage Plate ................... 4–7
Figure 4–3. Routing Load Cell Cables ......................................... 4–8
Figure A–1. Hydraulic Filter Bypass Indicator............................ A–6
Figure B–1. Model 5850v2 Menu Map ........................................B–3
Page 10
x
LIST OF TABLES
Table Title Page
Table 2–1. Control Panel Keys and Button ................................... 2–2
Page 11
Model 5850v2 1–1
1. INTRODUCTION
CHAPTER 1
INTRODUCTION TO THE MODEL 5850V2
The Model 5850v2 is Troxler’s newest Superpave™ Gyratory Compactor and the most advanced, easiest to use gyratory compactor on the market today. This chapter introduces the Model 5850v2 and provides information on operating the compactor safely. This chapter also includes a list of parts and accessories, and instructions for unpacking and inspecting the system.
SAFETY WARNINGS
The Troxler Model 5850v2 is a safe, durable gyratory compactor. Troxler cannot anticipate every example of improper or unauthorized use of this unit that may lead to malfunction or accident. Thus, if a particular use is not specifically mentioned in this manual as authorized, then consult Troxler about the alternate use. Otherwise, it is assumed that the use is unauthorized and improper.
To ensure minimal operator risk, Troxler recommends the following safety precautions:
Wear safety glasses when preparing an asphalt specimen. Always wear heat-resistant gloves when handling any hot
substance.
When moving the mold, grasp it firmly on either side under the
top flange.
Remove all objects, except the mold and asphalt specimen, from
the compaction chamber before pressing the START key.
Do not operate the compactor with the chamber door or any
panels removed.
Page 12
1–2
Do not wear loose clothing or jewelry when operating the
compactor.
Keep hands away from the gyratory compactor when the unit is
in motion.
With the service panels removed, the gyratory compactor poses
an electrical hazard. Unplug the gyratory compactor before removing the panels.
Page 13
Model 5850v2 1–3
1. INTRODUCTION
CAUTIONS AND WARNINGS
Identification of Interconnects:
Lower Left Side of Compactor
Connection for 100 – 240 VAC, 50/60 Hz power to the
compactor
Upper Left Side of Compactor
9-pin RS-232C serial interface for connecting the
compactor to a computer or serial device
USB port for connecting the compactor to a USB
printer or memory device
Page 14
1–4
INTRODUCTION
The Troxler Model 5850v2 Superpave Gyratory Compactor provides compaction of asphalt specimens at a given pressure, angle, and number of gyrations. The Model 5850v2 meets or exceeds all Federal Highway Administration (FHWA) Superpave specifications.
The Model 5850v2 Gyratory Compactor provides safe, reliable gyratory compaction of asphalt specimens using a compaction pressure and gyration angle selected by the operator. The method of specimen compaction is crucial to creating asphalt specimens that behave similar to asphalt used in construction and in obtaining meaningful test results.
Building upon the successes of Troxler’s Model 4140 and 4141
Gyratory Compactors, the Model 5850v2 has been completely redesigned with improved electronics, a robust compaction system, and software-adjustable angle of gyration. The durable Model 5850v2 will consistently stand up to the rigors of any asphalt lab.
SAFE OPERATION
For operator safety, all moving parts are covered and cannot be physically accessed during compaction. An interlock switch prevents the gyratory compactor from operating with the
compaction chamber door open. The red EMERGENCY safety switch located at the bottom of the control panel stops all moving parts.
WARNING
Do not operate the Model 5850v2 Gyratory Compactor with the chamber door or any panels removed.
Page 15
Model 5850v2 1–5
1. INTRODUCTION
EASE OF OPERATION
The Model 5850v2 is calibrated and ready to use upon arrival. The unit will compact asphalt samples to a specific height or a specific number of gyrations, as selected by the operator. The angle of gyration is recorded with every gyration, assuring angle stability.
As selected by the operator, the Model 5850v2 provides a compaction pressure of 200 to 1000 kPa and an angle of gyration between 0.00 and 1.50 degrees. Angle and pressure adjustments can be performed quickly and easily using the keypad.
For ease of operation, the Model 5850v2 provides a fully automatic method of compaction. The Model 5850v2 compacts an asphalt specimen at the touch of a single key.
NOTE
Do not attempt to operate the Model 5850v2 before reading this manual and the safety warnings posted on the unit. Troxler stresses that the operator is solely responsible for ensuring the safe use of the Model 5850v2. The manufacturer, its subsidiaries, distributors, or representatives cannot assume responsibility for any mishaps, damage, or personal injury which may occur from failure to observe the safety warnings in this manual and posted on the unit.
The Model 5850v2 can be equipped with 150-mm, 100-mm, or 4­inch diameter molds, and can compact specimens with heights of up to 185 mm.
The Model 5850v2 features USB and serial ports for transferring data to USB or serial devices. The operator may choose to automatically send the compaction data to a computer, printer, or USB device upon completion of a compaction cycle.
NOTE
A list of USB memory devices and printers that are compatible with the Model 5850v2 Gyratory Compactor is available on the 5850v2 product page of the Troxler website (www.troxlerlabs.com).
Page 16
1–6
The Model 5850v2 also provides storage for and allows manual printing of the last 20 compacted specimens. All output is in SI units as described in American Society of Testing and Materials (ASTM) SI10, Standard for Use of the International System of Units (SI): The Modern Metric System.
CARE AND MAINTENANCE
The Model 5850v2 requires little maintenance. To reduce the effects of gyration on moving parts, the gyratory compactor requires regular cleaning and lubrication. For a schedule of machine maintenance, refer to Appendix A.
Page 17
Model 5850v2 1–7
1. INTRODUCTION
Figure 1–1. Model 5850v2 Gyratory Compactor
Page 18
1–8
PARTS AND ACCESSORIES
The Model 5850v2 includes the electrical and mechanical parts required to continuously compact hot-mix asphalt. Use Figure 1–1 to locate and identify the following parts:
The power switch is located on the left side of the compactor. The emergency stop switch stops all machine movement. The keypad and display provide the interface. The mold (not shown) with the lower puck inserted receives the
asphalt for making specimens. Troxler offers molds with inside diameters of 150 mm, 100 mm, and 4 inches. (Part numbers 116066 and 116069)
The USB and serial ports enable the operator to print or
download data to a USB or serial device.
The USB cable (not shown) connects the compactor to the
printer or other USB device. (Part number 110697)
The serial cable (not shown) connects the compactor to a serial
device, such as a computer. (Part number 106514)
The extruder is used to remove a compacted specimen from the
mold.
The cooling table is used to the compacted specimen. The height standard assembly (not shown) is used to calibrate
the specimen height. (Part number 106989)
The Model 5850v2 Manual of Operation and Instruction (not
shown) provides the operating instructions for the compactor.
The printer (not shown) allows the operator to print data. (Part
number 116220)
The specimen papers (not shown) prevent the asphalt specimen
from sticking to the puck and ram head. (Part number 106953)
The optional Pressure Verification Kit (not shown) allows the
operator to verify the pressure calibration. The pressure is initially calibrated at the factory. (Part number 108706)
Page 19
Model 5850v2 1–9
1. INTRODUCTION
INSPECTION
Upon receiving the Model 5850v2 Gyratory Compactor from the factory, perform a complete inspection and inventory as described below.
Check to see that the following are included:
Model 5850v2 Gyratory Compactor Mold Power cord Height standard assembly Specimen papers (500 per package) Printer USB cable Serial cable Manual of Operation and Instruction
Inspect each part for damage that may have occurred during shipment. If any parts or accessories appear damaged, notify the carrier and your Troxler representative immediately.
Page 20
1–10
UNPACKING
WARNING
The Model 5850v2 Gyratory Compactor weighs approximately 227 kg (500 lb). To prevent personal injury or equipment damage, exercise care while unpacking and lifting the unit.
NOTE
Troxler recommends that all packaging material be saved. It may be reused to pack the compactor for shipping.
11..
To remove the shipping carton from the top of the unit, cut each side of the carton approximately 2 inches above the pallet. Lift the carton up and off the unit.
22..
Remove the metal strap and bolts that secure the compactor to the pallet.
33..
Remove the two brackets that secure the front casters in place. The compactor is now free to roll on the pallet.
WARNING
To prevent personal injury or equipment damage, do not tip the compactor while lifting it from the pallet.
44..
Using a forklift, lift the compactor from the pallet.
CAUTION
When using a forklift, lift the compactor from the side to prevent equipment damage.
Page 21
Model 5850v2 1–11
1. INTRODUCTION
SITE SELECTION
After unpacking and inspecting the compactor as described in the previous sections, select a suitable site for installation. Apply the following criteria in selecting the installation site:
Place the compactor on a flat, level location. Locate the compactor no more than 1.2 m (4 ft) from the
required electrical power source (see Appendix C). Ensure that the distance does not place stress on the power cord. The power source must be wired by a qualified electrician.
The power switch is located on the left side panel, as shown in
Figure 1–1. Ensure that the placement of the compactor provides easy access to the power switch.
Page 22
1–12
ASSEMBLY
11..
The hydraulic reservoir is filled with a premium quality, light grade (ISO VG 32, SAE 10) hydraulic oil prior to shipping. Before using the compactor, check the oil level as follows:
aa..
Remove the rear service panel from the compactor.
bb..
Locate the fill level sight glass as shown in Figure 1–2.
NOTE
Use only a light grade (ISO VG 32, SAE 10, Troxler part number 018203) hydraulic oil to fill the hydraulic reservoir.
22..
Ensure that the oil level is at the 30-degree mark on the sight glass, as shown in Figure 1–3. If oil is needed:
aa..
Remove the reservoir fill cap (see Figure 1–2) and place a funnel into the fill tube as shown in Figure 1–4.
bb..
Add oil until the level is at the 30-degree mark.
cc..
Remove the funnel and replace the reservoir fill cap.
dd..
Re-install the rear service panel.
Figure 1–2. Hydraulic Reservoir
RESERVOIR
FILL CAP
FILL LEVEL
SIGHT GLASS
Page 23
Model 5850v2 1–13
1. INTRODUCTION
Figure 1–3. Proper Reservoir Fill Level
Figure 1–4. Place a Funnel in Reservoir Fill Tube
ENSURE
FLUID LEVEL
IS AT 30-DEGREE
MARK
FUNNEL
Page 24
1–14
33..
Following the site selection guidelines in the previous section, set the compactor in place.
44..
Lock the casters so that the unit remains in place.
55..
Plug the ac power cord into the ac power inlet on the compactor’s lower left panel (see Figure 1–1 on page 1–7).
66..
Connect the ac power cord to the required ac power source (refer to Appendix C).
NOTE
On 240 VAC units, a connector must be installed on the ac power cord. The connector must meet local safety and electrical code requirements. Refer to the Electrical Specifications section on page C–3 for the current and voltage ratings for the compactor.
77..
If using the compactor with a USB printer or memory device, connect the device to the USB port located on the upper left side of the compactor (see Figure 1–1 on page 1–7).
NOTE
A list of USB memory devices and printers that are compatible with the Model 5850v2 Gyratory Compactor is available on the 5850v2 product page of the Troxler website (www.troxlerlabs.com).
88..
If using the compactor with a computer, use a serial cable to connect the computer to the serial port located on the upper left side of the compactor (see Figure 1–1 on page 1–7).
Page 25
Model 5850v2 2–1
2. SETUP & OPERATION
CHAPTER 2
SETUP AND OPERATION
This chapter describes how to get started using the Model 5850v2 Gyratory Compactor. This information includes a brief description of the control panel and instructions for turning the compactor on, setting it up, and compacting an asphalt specimen.
Page 26
2–2
CONTROL PANEL
Figure 2–1 shows the layout of the Model 5850v2 Gyratory Compactor control panel. Table 2–1 lists the functions for each key and button on the panel.
Table 2–1. Control Panel Keys and Button
KEY
FUNCTION
EMERGENCY
Stops all machine movement. To release the button, rotate it clockwise.
START
Begins automatic compaction of asphalt specimen.
SETUP
Accesses the Setup functions. These include setting or viewing the run options, setting the data output options, calibrating the compactor, verifying the calibration, and clearing project data.
ESC
Returns to the next higher-level menu without updating or storing data. In response to Yes/No questions, it has the
same effect as pressing NO/CE. During gyration, it aborts the compaction cycle.
YES
Responds Yes to Yes/No questions.
NO/CE
Responds No to Yes/No questions. Also clears an incorrect entry and allows for re­entry.
 
Scrolls through menu options or views screens.
0...9
Enters numeric values.
.
Enters a decimal point.
ENTER
Enters data or views screens.
Page 27
Model 5850v2 2–3
2. SETUP & OPERATION
Figure 2–1. Model 5850v2 Control Panel Layout
Page 28
2–4
TURNING THE SYSTEM ON
NOTE
Control panel screens in this manual are intended as examples only. Values on your displays may differ slightly from those shown.
The power switch is located on the left side panel of the compactor (see Figure 1–1). After the compactor is turned on, it briefly displays the model and software version number, then performs a series of brief self-tests. After self-tests are completed, the compactor displays the Machine Idle screen shown below:
-Machine Idle­04-08-2008 11:02 AM G:100 AI:1.16 P:600
Press <START>
Where:
G = Operator-selected number of gyrations (this value is
999 if the compactor is set to compact to a target specimen height)
AI = Operator-selected internal angle of gyration P = Operator-selected compaction pressure
FIRST TIME SETUP
The Model 5850v2 is shipped with the current date and time (Eastern Standard Time) stored in its memory. By default, the date is displayed in mm/dd/yyyy format and the time in AM/PM format. To change the date, time, or display format, refer to page 5–3.
The Model 5850v2 provides a number of operator-definable options that control its operation. From the Setup menu, the operator can:
Select whether the compactor will run for a specified number of
gyrations (from 1 to 999) or until the specimen has been compacted to a specified height (50 to 200 mm). Then define
Page 29
Model 5850v2 2–5
2. SETUP & OPERATION
the desired ram pressure (200 to 1000 kPa)
Set the desired gyration angle (0.00 to 1.50 degrees)
Before using the compactor for the first time, ensure that these options are set properly. Press SETUP on the keypad to access
the Setup menu:
-Setup-
1- View Settings 2- Change Settings 3- Data Output
Press 1 to access the View Settings selection. The compactor displays:
Selected run count (number of gyrations) Selected mode (number of gyrations or specimen height) Specimen height Gyration angle Ram pressure Mold diameter Gyrate Delay
Refer to Chapter 3 for instructions on changing any of these selections.
The Model 5850v2 also provides numerous options for automatically outputting or printing data following a compaction cycle. The compactor can send the data to a computer or serial printer via the serial (RS-232) port, or to a USB printer or memory device (thumb drive) via the USB port.
NOTE
Page 30
2–6
A list of compatible USB memory devices and printers is available on the 5850v2 product page on Troxler’s website at www.troxlerlabs.com.
The output data can be formatted either in a height-versus-gyration table format or in a full table format which includes the height, ram pressure, gyration angle, and gyration rate for each gyration.
To automatically output gyration versus height data, connect the compactor to the computer or printer and turn on the Auto Output option as described on page 3–11.
NOTE
Before outputting data to a printer or computer, ensure that the Model 5850v2 is properly connected to the output device.
COMPACTING A SPECIMEN
WARNING
To prevent personal injury or equipment damage, before operating the Model 5850v2 Gyratory Compactor, become familiar with the safety warnings on page 1–1.
The following is a checklist for compacting an asphalt specimen with the Model 5850v2 Gyratory Compactor. Each step is discussed in detail in the following sections.
11..
Set up the gyratory compactor.
22..
Clean the mold tray, ram head, lower carriage, upper carriage assembly, and upper puck plate.
33..
Lubricate the ram head and upper puck plate with Magnalube­G.
Page 31
Model 5850v2 2–7
2. SETUP & OPERATION
44..
Prepare the asphalt mixture and place it in the mold.
55..
Place the mold in the compactor chamber, and compact the specimen.
66..
Remove the mold containing the compacted specimen from the compactor chamber and extrude the asphalt specimen using the built-in extruder provided with the compactor.
77..
Cool specimen on the cooling table.
Page 32
2–8
CLEANING AND LUBRICATING
CAUTION
Failure to properly clean and lubricate the Model 5850v2 before each use may result in compaction errors, premature equipment wear, and other problems.
Before operating the compactor:
11..
Vacuum the mold tray and compaction chamber.
22..
Clean the mold tray, lower carriage plate, and ram head (see Figure 2–2, View A), as well as the upper carriage assembly and upper puck plate (View B) with Bindoff or similar cleaner.
33..
Lubricate the ram head and the upper puck plate with Magnalube-G.
44..
Clean the mold and pucks with Bindoff or similar cleaner.
CAUTION
Do not use a degreasing cleaner or glass cleaner to clean the clear chamber door. To prevent damage to the door surface, use a mild detergent only.
Before each use:
11..
If necessary, clean the mold tray, lower carriage plate, and ram head (see Figure 2–2, View A), as well as the upper carriage assembly and upper puck plate (View B) with Bindoff or similar cleaner.
22..
Ensure that the exterior surface of the mold is free of dirt and asphalt residue.
33..
Lubricate the ram head with Magnalube-G.
44..
Inspect the upper puck plate. If dry, lubricate it with Magnalube.
Page 33
Model 5850v2 2–9
2. SETUP & OPERATION
LOWER
CARRIAGE
PLATE
RAM HEAD
MOLD TRAY
VIEW A
UPPER PUCK
PLATE
UPPER CARRIAGE ASSEMBLY
VIEW B
Figure 2–2. Compaction Chamber
Page 34
2–10
PREPARING A SPECIMEN
Lay the mold on its side and slowly insert the lower puck, with the small face down, into the mold. For the rest of this chapter, the mold with the puck inserted will be referred to as the mold.
WARNING
Always wear heat-resistant gloves when handling any hot substance. When moving the mold, firmly grasp it on either side under the top flange.
Place the asphalt mixture into an oven. Also place the mold (containing the lower puck) into the oven. Heat the asphalt mixture and mold to the compaction temperature of the mixture.
CAUTION
Do not heat the mold above 175 C (350 F). Heating above this temperature may warp the mold and create errors in the angle of gyration.
NOTE
Do not place the asphalt mixture into the mold while heating.
Remove the asphalt mixture from the oven, and place it on a work surface. Remove the heated mold from the oven and place it next to the hot-mix asphalt.
Place a specimen paper in the heated mold on top of the lower puck (see Figure 2–3). Load the hot asphalt mixture into the mold.
NOTE
To maintain the specimen temperature and prevent segregation of the specimen, the asphalt mixture must be loaded into the mold in one continuous motion. The paper thickness will affect compactor results; it is recommended that you use Troxler specimen papers
Page 35
Model 5850v2 2–11
2. SETUP & OPERATION
(part numbers 106952 or 106953).
Page 36
2–12
MOLD (WITH
LOWER PUCK
INSTALLED)
ASPHALT
SPECIMEN
PAPERS
MOLD
PULL
UPPER PUCK
Figure 2–3. Loading the Mold
Place another specimen paper on top of the asphalt mix. Place the upper puck, with its large side down, into the mold. Keep the upper puck oriented horizontally while inserting it to prevent it from becoming wedged in the mold.
CAUTION
If the upper or lower puck becomes wedged in the mold, it must be removed and inserted correctly before compacting the asphalt specimen.
Wearing heat-resistant gloves and safety glasses, place the hot
mold on the mold tray (see Figure 2–2, View A, on page 2–9).
Slide the mold into the compaction chamber so that it rests against the two locating pins at the back of the lower carriage plate. Close
Page 37
Model 5850v2 2–13
2. SETUP & OPERATION
the chamber door.
Page 38
2–14
COMPACTING THE SPECIMEN
The Model 5850v2 Gyratory Compactor provides a fully automatic method of controlling compaction. In Automatic mode, the operator begins the compaction cycle using a single keystroke. The Model 5850v2 compacts the specimen based on the number of gyrations or the target specimen height specified by the operator. In Automatic mode, the compactor can also automatically print or download compaction data upon completion of the compaction cycle.
Place the loaded mold into the compaction chamber and close the chamber door. Press START.
If there is no mold in the chamber, or if the mold is not in the proper location, the compactor displays an error message.
If the mold is in place, the compactor begins the compaction cycle. The compactor clamps the mold, raises the ram into position, induces the angle of gyration, and begins compaction. During the compaction cycle, the compactor displays a screen similar to the one shown below:
-Gyrating-
Gyration: #:## Spec. Ht.: ###.# mm G:100 AI:1.16 P:600
Where:
Gyration # =
Number of gyrations completed
Spec. Ht. =
The current specimen height
G =
Operator-selected number of gyrations (this value is 999 if the compactor is set to compact to a target specimen height)
AI =
Internal angle of gyration
P =
Operator-selected compaction pressure
Page 39
Model 5850v2 2–15
2. SETUP & OPERATION
The compactor continues until the desired number of gyrations or target specimen height, as selected by the operator, is reached. The compactor then unclamps the mold, removes the angle of gyration, and lowers the ram to its home position.
If the Post Gyrate Delay function is enabled (see page 3–8), the compactor will center itself and maintain a minimal pressure for five minutes before unclamping the mold and lowering the ram.
If the Auto Output function (see page 3–11) is enabled, the compactor automatically outputs the gyration versus height data.
The compactor then returns to the Machine Idle display shown on page 2–4.
Open the chamber door and, wearing heat-resistant gloves, remove the mold from the compaction chamber. Extrude the specimen from the mold using the extruder provided with the unit. You can also use the pneumatic extruder, available from your Troxler representative.
REMOVING THE SAMPLE FROM THE MOLD
1. Using the Extruder Positioning Buttons, lower the extruder to
the lowest position.
2. Remove sample mold from the chamber and slide the mold into
the extruder rails from left to right.
3. Using the Extruder Positioning Buttons, raise the extruder until
the sample releases from the mold.
4. Using the Extruder Positioning buttons, lower the extruder to
the lowest position.
5. Remove mold from extruder.
Page 40
2–16
COOLING THE SAMPLE
1. Place sample on Cooling Table.
2. Power-up the Cooling Table Fan.
SHEAR OPTIONS & PERFORMANCE TESTS
The Model 5850v2 can compact samples as tall as 185mm for use with AMPT (Asphalt Mix Performance Tester). The compactor also offers a shear option, either before or after purchase. This optional feature includes transducers that measure the shear forces acting on the specimen during gyration.
The Model 5850v2 also utilizes the Gyratory Shear Kit (GSK), which turns any gyratory compactor into a shear-enabled unit without the expense of purchasing the shear option. Place the 1.125” tall device in your 150mm mold, fill with mix, and run the specimen. The GSK calculates the shear moment at each rotation.
For more information about the shear option, or to learn more about the Gyratory Shear Kit, contact Troxler at 1-877-TROXLER or visit our website at www.troxlerlabs.com.
Page 41
Model 5850v2 3–1
3. SETUP MENU
CHAPTER 3
SETUP MENU
The compactor’s Setup menu enables the operator to select and define the operating parameters of the Model 5850v2 Gyratory Compactor. This chapter describes the many menu options.
Page 42
3–2
SETUP MENU
The compactor’s Setup menu enables the operator to select and define the operating parameters of an automatic compaction cycle, to determine the destination and format for outputting or downloading compaction data, to calibrate the compactor, and to perform other special functions.
To access the Setup menu, press SETUP on the keypad. Use the arrow keys to scroll through the menu options. To select an option, press the numeric key that corresponds to desired option. The following sections describe each selection.
-Setup-
1- View Settings 2- Change Settings 3- Data Output
-Setup-
4- Home Position 5- Calibration 6- Special
Page 43
Model 5850v2 3–3
3. SETUP MENU
VIEW SETTINGS
To view the currently selected run options, select View Settings from the Setup menu shown on page 3–2. The compactor displays:
Selected run count (number of gyrations) Selected mode (number of gyrations or specimen height) Specimen height Gyration angle Ram pressure Mold diameter Gyrate Delay Press ESC to return to the Setup menu.
Page 44
3–4
CHANGE SETTINGS
The Change Settings selection from the Setup menu allows you to:
Select whether the compactor will run for a specified number of
gyrations or until the specimen has been compacted to a specified height
Specify the number of gyrations (from 1 to 999) the compactor
will run when compacting a specimen
Set the desired specimen height Set the desired gyration angle (0.00 to 3.0 degrees) Define the desired ram pressure (200 to 1000 kPa) Select the mold diameter (150-mm, 100-mm, or 4-inch)
To access these options, press 2 from the Setup menu (see page 3–2). The Change Settings menu displays, as shown below. Use the arrow keys to scroll through the menu options. To select an option, press the numeric key that corresponds to desired option. The following sections describe each selection.
-Change Settings-
1- Operation Mode 2- # of Gyrations 3- Height
-Change Settings-
4- Angle 5- Pressure 6- Mold Diameter
-Change Settings-
7- Post Gyrate Delay
Page 45
Model 5850v2 3–5
3. SETUP MENU
OPERATION MODE
The Model 5850v2 provides two modes of gyration. Based on operator selection, the unit may either compact the specimen for a set number of gyrations or until the specimen reaches a specified target height. The default mode of gyration is the number of gyrations.
To select the gyration mode, press 1 from the Change Settings menu shown on page 3–4. The compactor displays the Operation Mode menu shown below.
-Operation Mode­1- # Gyrations 2- Specimen Height
Press # to Select
Press the numeric key that corresponds to the desired operation mode. The compactor displays a brief confirmation message, and then returns to the Change Settings menu.
NUMBER OF GYRATIONS
To enter the number of gyrations for a compaction cycle, press 2 from the Change Settings menu shown on page 3–4. The compactor displays:
Input Number of
Gyrations
100
Press <ENTER>
Use the number keys to enter the desired number of gyrations (from 1 to 999). Use the NO/CE key to backspace. Press ENTER. The display returns to the Change Settings menu.
Page 46
3–6
SPECIMEN HEIGHT
The Model 5850v2 can also compact the asphalt specimen to a specified target height. The operator can specify a height of 50 to 200 mm. The final specimen height may vary slightly from the value entered. Differences in specimen height are mix dependent. If the height is not acceptable, modify the height set on the unit.
To set the desired specimen height, press 3 from the Change Settings menu shown on page 3–4. The compactor displays:
Input Target
Specimen Height (mm)
115.0
Press <ENTER>
Use the number keys to enter the specimen height (50 to 200 mm). Use the NO/CE key to backspace. Press ENTER. The display
returns to the Change Settings menu.
GYRATION ANGLE
The Model 5850v2 can be set to an internal gyration angle of 0.00 to 1.50 degrees. To set the angle, press 4 from the Change
Settings menu shown on page 3–4. The compactor displays:
Input Gyration Internal Angle
1.16
Press <ENTER>
Use the number keys to enter the desired gyration angle (from 0.00 to 1.50 degrees). Use the NO/CE key to backspace. Press ENTER. The display returns to the Change Settings menu
shown on page 3–4.
Page 47
Model 5850v2 3–7
3. SETUP MENU
PRESSURE
NOTE
To ensure proper compactor operation, calibrate the angle as described in Chapter 4 after changing the ram pressure.
The Model 5850v2 ram pressure can be set between 200 and 1000 kPa. To set the ram pressure, press 5 from the Change
Settings menu shown on page 3–4. The compactor displays:
Input Compaction
Pressure (kPa)
600
Press <ENTER>
Use the number keys to enter the desired ram pressure (from 200 to 1000 kPa). Use the NO/CE key to backspace. Press ENTER. The display returns to the Change Settings menu.
MOLD DIAMETER
CAUTION
Ensure that the mold diameter selected in the compactor software is correct for the mold size in use before compacting a specimen. Failure to select the proper mold diameter in the software can cause erroneous compaction results or equipment damage.
NOTE
To ensure proper compactor operation, calibrate the compaction pressure and specimen height as described in Chapter 4 after changing the mold diameter.
The Model 5850v2 can produce 150-mm, 100-mm, or 4-inch asphalt specimens.
Page 48
3–8
To configure the compactor software for the diameter of the mold in use, press 6 from the Change Settings menu on page 3–4. The compactor displays:
-Mold Diameter­1- 150mm 2- 100mm 3- 4in
Press the numeric key that corresponds to the desired mold diameter. The compactor displays a brief confirmation message, and then returns to the Mold Diameter menu shown above. Press ESC to return to the Change Settings menu shown on page 3–4.
POST GYRATE DELAY
The Model 5850v2 provides the option for a five-minute delay upon completing the compaction of a specimen. This delay maintains a minimum pressure on the sample and allows low gyration specimens to cool before the ram lowers.
Press SETUP button, and Change Settings.
To enable the Post Gyration Delay, scroll using the ↑↓ buttons, press 7 from the Change Settings menu. The compactor displays:
-Post Gyrate Delay­1- Enable 2- Disable 3- Set Delay Time
Press 1 to enable the function and press 2 to disable it. The compactor briefly displays the message Post Gyration Delay is Enabled (or Disabled).
Page 49
Model 5850v2 3–9
3. SETUP MENU
Select 3 to change Post Gyrate Delay time.
NOTE
Gyration process will proceed as normal.
Input Number of
Minutes
XX
Press <ENTER>
Valid entries of 1 to 90 minutes for extra time when post delay is needed.
-Post Gyrate Delay­MM:SS
Remaining
<ESC> to Abort
When the post-gyrate delay is enabled, after gyrations are complete the screen will display:
NOTE
Where MM represents minutes and SS represents seconds.
During the delay, the pump remains on. The carriage plate is centered, the pressure is set to minimum and the ram position remains constant. The time counts down until it has elapsed or
pressing ESC to Abort early.
Once the time has expired, the process is completed as usual; ram is lowered, pump is turned off and data is output (enabled).
Page 50
3–10
DATA OUTPUT
The Model 5850v2 provides numerous options for outputting or printing data. Compaction data can be printed manually from the compactor’s memory or automatically upon completion of a compaction cycle.
The compactor can send the data to a computer or serial printer via the serial (RS-232) port, or to a USB printer or memory device (thumb drive) via the USB port.
NOTE
A list of USB memory devices and printers that are compatible with the Model 5850v2 Gyratory Compactor is available on the 5850v2 product page on the Troxler website (www.troxlerlabs.com).
The output data can be presented in either a height-versus-gyration or full table format. These options are described on page 3–12.
NOTE
Before outputting data to a printer or computer, ensure that the Model 5850v2 is properly connected to the output device.
To configure the data output options, press 3 from the Setup menu (see page 3–2). The compactor displays the Data Output menu shown below. Use the arrow keys to scroll through the menu options. To select an option, press the numeric key that corresponds to desired option. The following sections describe each selection.
-Data Output-
1- Output Record
2- Auto Output
3- Output Device
-Data Output-
4- Output Format
Page 51
Model 5850v2 3–11
3. SETUP MENU
OUTPUT RECORD
The Output Record function allows the operator to manually
download or print compaction data stored in the compactor’s
memory. The compactor stores up to 20 data records that contain information on the last 20 compaction cycles. Each data record includes the sample height (in mm), ram pressure, gyration angle, and gyration rate versus the gyration number for a specimen, as well as the date and time of compaction. Printed table format data sets also include a blank for the Sample ID.
To manually download or print a data record, press 3 from the Data Output menu shown on page 3–10. The compactor searches the data records and then displays the specimens currently stored in memory, as shown below:
>04/08/09 04:24P 04/08/09 01:52P 04/08/09 08:45A 04/08/09 08:15A
Using the arrow keys, move the cursor () to the desired data record and press ENTER. The compactor sends the specimen data in the
desired format to the selected device (see page 3–12), then returns to the Data Output menu.
AUTO OUTPUT
Upon completion of a compaction cycle, the Model 5850v2 can automatically download or print gyration data via the serial or USB port.
To toggle the Auto Output feature on or off, press 2 from the Data Output menu shown on page 3–10. The compactor briefly displays the message Auto Output Is Now ON (or OFF), then returns to the Data Output menu.
Page 52
3–12
OUTPUT DEVICE
The compactor can send the data to a computer or serial printer via the serial (RS-232) port, or to a USB printer or memory device (thumb drive) via the USB port. To select the destination for the
output data, press 3 from the Data Output menu shown on page 3–10. The compactor displays:
-Output Destination­1- Serial Port 2- USB Printer 3- Thumb Drive
Press the numeric key that corresponds to the desired output destination. The compactor displays a brief confirmation message
and returns to the Output Destination menu. Press ESC to return to the Data Output menu.
The GyroImport software is used to convert the data on the USB memory device to a Microsoft Excel workbook. The software may be downloaded from the 5850v2 product page on the Troxler website (www.troxlerlabs.com) or it can be requested from Customer Service at 1-877-TROXLER.
OUTPUT FORMAT
The Model 5850v2 outputs data in a height-versus-gyration format, similar to the one shown in Figure 3–1, and shows the specimen height, or thickness, for each gyration during a compaction cycle. A full table output includes specimen height, gyration angle, ram pressure, and shear stress (if enabled) for each gyration.
To print the output data, press 4 from the Data Output menu (shown on page 3–10). The compactor displays:
-Output Format­1- Table 2- Formatted 3- GyroPave
Page 53
Model 5850v2 3–13
3. SETUP MENU
Press 1 to select the Table format. The compactor displays a brief confirmation message, and then returns to the Data Output menu.
Figure 3–1. Sample Height Versus Gyration Table
Press 2 to select the formatted data. The data is output in Comma Separated Variable (.csv) format. The compactor displays a confirmation message, and then returns to the Data Output menu.
Press 3 to select GyroPave software compatible data format. The data is similar to the Table format, but only height measurements are output. The compactor displays a confirmation message and then returns to the Data Output menu.
NOTE
If Thumb Drive is the selected output device, the result will be the following files: Ax.hdr (header file); Ax.txt (formatted data format); AxGP.txt (GyroPave data format); AxTABLE.txt (table data format). (Where “x” represents the file index number of the data stored in the compactor’s memory.)
Page 54
3–14
HOME POSITION
The Model 5850v2 contains hydraulic actuators that control specimen compaction. One actuator applies ram pressure; another actuator clamps the mold; and two actuators inside the compaction chamber set and control the gyration angle.
The Home Position function returns all the hydraulic actuators to their home position. To access this function, press 4 from the
Setup menu (see page 3–2). The compactor drives the four actuators to their home position, while displaying Moving Gyratory to Home Position. When the actuators are in their home position, the compactor returns to the Setup menu.
CALIBRATION
Chapter 4 describes the calibration functions available from the compactor’s Calibration menu. To access this menu, press 5 from the Setup menu (see page 3–2).
SPECIAL
Chapter 5 describes the functions available from the compactor’s Special menu. To access this menu, press 6 from the Setup menu (see page 3–2).
Page 55
Model 5850v2 4–1
4. CALIBRATION
CHAPTER 4
CALIBRATION
The Model 5850v2 allows for simple calibration of the specimen height and compaction pressure, and for offsetting the angle of gyration. This chapter provides a recommended schedule for calibration and verification of these parameters, as well as instructions for performing these procedures.
Page 56
4–2
CALIBRATION SCHEDULE
The Troxler Model 5850v2 Gyratory Compactor is calibrated at the factory, and requires no initial calibration upon receipt.
Troxler recommends the following calibration schedule for the Model 5850v2. If calibrating the compaction pressure and specimen height, calibrate the pressure first and then calibrate the height.
NOTE
To ensure proper compactor operation, calibrate the compaction pressure and specimen height after changing the ram pressure (see page 3–7).
PRESSURE CALIBRATION
See page 4–6 for details on pressure calibration. Calibrate the compaction pressure every 3 months.
SPECIMEN HEIGHT CALIBRATION
See page 4–10 for details on specimen height calibration.
Calibrate the specimen height daily. Calibrate the specimen height after calibrating the compaction
pressure.
ANGLE VERIFICATION AND OFFSET
See page 4–3 for details on angle verification.
Verify the angle as described on page 4–3 after every 800 samples or once per year, whichever comes first. If the angle is more than ±0.03° from the target, use the Angle Offset function as described on page 4–12.
Page 57
Model 5850v2 4–3
4. CALIBRATION
ANGLE VERIFICATION
The operator-selected internal angle of gyration is displayed on the Machine Idle screen as well as during gyration. This angle can be easily verified using an internal angle device, such as the Dynamic Angle Verification (DAV) device available from Troxler (part number 108706).
To verify the internal angle, follow the instructions in Chapter 3 to:
11..
Set the operation mode to number of gyrations.
22..
Set the number of gyrations to 20.
33..
Set the compaction pressure to 600 kPa.
44..
Set the gyration angle to 1.16.
NOTE
To ensure the accuracy of internal angle measurements, the probes of the internal angle device must be aligned with the edge of the mold pull as shown below.
Figure 4–1. Aligning the Internal Angle Device Probes
Page 58
4–4
55..
Follow the instructions provided with the internal angle device to measure the bottom angle. Ensure that the probes of the internal angle device are aligned along Position 1 with the edge of the mold pull as shown in Figure 4–1.
66..
Remove the mold from the chamber and record the measured angle from the internal angle device (if you use a device with recording capabilities).
77..
Repeat the two previous steps to obtain a second bottom angle measurement where the device is aligned along Position 2.
88..
Follow the instructions provided with the internal angle device to measure the top angle. Ensure that the probes of the internal angle device are aligned along Position 1 with the edge of the mold pull as shown in Figure 4–1.
99..
Remove the mold from the chamber and record the measured angle from the internal angle device.
1100..
Repeat the two previous steps to obtain a second top angle measurement where the device is aligned along Position 2.
1111..
Calculate the average of the bottom angle and top angle measurements (four measurements total).
1122..
Compare the average to the entered angle of 1.16. If the difference is more than ±0.03°, refer to the Angle Offset section on page 4–12.
Page 59
Model 5850v2 4–5
4. CALIBRATION
CALIBRATION
WARNING
To prevent personal injury or equipment damage, before operating the Model 5850v2 Gyratory Compactor, become familiar with the safety warnings on page 1–1.
The Model 5850v2 allows for simple calibration of the compaction pressure and specimen height, and for offsetting the gyration angle.
To access the Calibration menu, press 5 from the Setup menu shown on page 3–2. The compactor displays:
-Calibration-
1- Pressure 2- Height 3- Angle Offset
-Calibration-
4- Print Calibration
Use the arrow keys to scroll through the menu options. To select an option, press the numeric key that corresponds to desired option. The following sections describe each selection.
Page 60
4–6
PRESSURE
NOTE
For optimum performanceif operating the compactor at a ram pressure other than 600 kPacalibrate the specimen height and gyration angle after changing the ram pressure (see page 3–7).
The Pressure Verification Kit includes all the equipment needed to calibrate and/or verify the compaction pressure, including a calibration load cell.
Before calibrating or verifying the pressure, clean the compactor and connect the load cell as described below:
11..
To remove any grease or asphalt, clean the mold tray, ram head, lower carriage plate, upper carriage assembly, and upper puck plate (see Figure 2–2 on page 2–9) with Bindoff or similar cleaner.
22..
Connect the load cell as follows:
aa..
Using the supplied serial cable, connect the load cell to the control unit’s serial port.
bb..
Connect the dc charger to the load cell, and plug the charger into an electrical outlet.
To begin pressure calibration, press 1 at the Calibration menu shown on page 4–5. The compactor displays:
Connect Load cell to ser. Port. Set it in chamber (ON A PUCK!)
Press <ENTER>
CAUTION
Ensure that the load cell is placed on a puck as described below. Failure to do so will cause damage to the load cell.
Page 61
Model 5850v2 4–7
4. CALIBRATION
11..
Place the lower puck, larger edge down, in the center of the lower carriage plate as shown in Figure 4–2.
22..
Place the calibration load cell in the center of the puck as shown below.
33..
Place the upper puck, larger edge down, centered on top of the load cell.
44..
Route the load cell cables through the notch in the upper center of the chamber opening as shown in Figure 4–3. Close the chamber door.
Figure 4–2. Puck Centered on Lower Carriage Plate
PUCK
LOWER
CARRIAGE PLATE
LOAD
CELL
Page 62
4–8
Figure 4–3. Routing Load Cell Cables
ROUTE CABLES
THROUGH
NOTCH
LOAD
CELL
Page 63
Model 5850v2 4–9
4. CALIBRATION
CAUTION
Use caution when opening and closing the chamber door to prevent catching or pinching the load cell cables.
55..
Press ENTER. The compactor measures the unloaded pressure on the load cell. During this measurement, the control unit displays:
Pressure Cal/Verify Testing Calibration Load Cell
Please Wait
NOTE
If the load cell is not properly connected, the control unit briefly displays the following error message. Check the load cell connection. Press ENTER to continue.
Pressure Cal/Verify Communication Error Check Load Cell
Press <ENTER>
66..
After measuring the unloaded pressure on the load cell, the compactor raises the ram until the load cell contacts the upper puck plate. The compactor then applies pressure and displays:
Pressure Cal/Verify
Applying Pressure
During calibration and verification, the compactor raises the compaction ram and performs a series of pressure measurements at high and low pressure. Upon completion, the compactor verifies the pressure calibration, and then displays the compaction pressure as measured internally by the compactor (System) and as measured by the load cell (Load Cell):
Page 64
4–10
-Pressure Readings­ System: ### Load Cell: ###
Press <ENTER>
77..
If the System pressure differs from the Load Cell pressure by more than 10 kPa, or if the System pressure is not within 600 18 kPa, check all cable connections and the position of the load cell and puck. Repeat the calibration. If repeated attempts to calibrate the pressure fail, contact your Troxler representative.
88..
Press ENTER. The compactor stores new calibration constants based on the System and Load Cell values. It then lowers the ram and returns to the Calibration menu shown on page 4–5.
99..
Open the chamber door and remove the calibration load cell and pucks. Unplug the dc charger from the electrical outlet, and disconnect the load cell from the dc charger and control unit. Return all parts to the Performance Verification Kit case.
SPECIMEN HEIGHT
If calibrating the height and pressure, calibrate the pressure first. Then calibrate the specimen height.
NOTE
For optimum performanceif operating the compactor at a ram pressure other than 600 kPacalibrate the specimen height and gyration angle after changing the ram pressure.
NOTE
Before calibrating the specimen height, clean the ram head, lower carriage plate, upper carriage assembly, and upper puck plate with de-greaser. Failure to do so may cause the height calibration to be inaccurate.
Page 65
Model 5850v2 4–11
4. CALIBRATION
A height standard assembly is supplied with each compactor. This standard, along with two pucks and two specimen papers, is used to calibrate the specimen height.
11..
To begin height calibration, press 2 at the Calibration menu shown on page 4–5. The compactor displays:
Put Height Std, Pucks and Papers Into the Chamber
Press <ENTER>
22..
Place a clean puck, with the large side down, in the center of the carriage plate. Place two specimen papers and the height standard assembly in the center of the puck. Place a second clean puck on the top of the height standard assembly.
33..
Close the chamber door and press ENTER. The compactor displays:
Height Calibration
Enter Std Height
###.##
Press <ENTER>
The height of the height standard assembly is stamped on its side. Enter the height to the nearest hundredth and press ENTER. The compactor finds its home position and then raises the ram until the
upper puck reaches the upper puck plate.
The compactor then applies pressure and waits for the pressure to stabilize. When the pressure has stabilized, the compactor takes a series of measurements and then verifies the height calibration.
When the calibration is complete, the compactor displays the Measured height and the Standard height, as shown below. The
displayed height should be within 0.10 mm of the value stamped on the height standard assembly. If not, repeat the height calibration.
Page 66
4–12
Height Calibration Measured:###.##mm Standard:###.##mm Press <ENTER>
44..
Press ENTER. The compactor stores the new calibration constants based on the Measured and Standard values. It then displays the message Calibration Finished and lowers the ram to its home position. When the ram reaches the home position, the compactor returns to the Calibration menu shown on page 4–5. Open the chamber door and remove the height standard assembly, pucks, and specimen papers.
ANGLE OFFSET
The Model 5850v2 can be set to a gyration angle of 0.00 to 1.50 degrees. As noted earlier, Troxler recommends verifying the angle after every 800 samples or once per year using an internal angle device, such as the Dynamic Angle Verification (DAV) device available from Troxler. Refer to page 4–3 for instructions on verifying the angle.
Use the internal angle device during verification to take two bottom angle measurements and two top angle measurements. Determine the average of these four measurements. If the average angle is more than ±0.03° from the target, the Angle Offset function can be used to compensate for the difference by comparing control system feedback parameters to the average measured internal angle.
To use the Angle Offset function, press 3 at the Calibration menu shown on page 4–5. The compactor displays:
-Angle Offset-
0.00 Degrees 1- Change 2- Enable
Page 67
Model 5850v2 4–13
4. CALIBRATION
Press 1 to enter the average of the four internal angle measurements. The compactor displays:
Input Measured Internal Angle
#.###
Press <ENTER>
Enter the measured angle and press ENTER. The compactor displays the following (where #.## is the value just entered):
-Angle Offset­ #.## Degrees 1- Change 2- Enable
To enable the Angle Offset function using this value, press 2.
PRINT CALIBRATION
The Print Calibration function can be used to manually download or print calibration data from the compactor. To use this function,
press 4 at the Calibration menu shown on page 4–5. The compactor sends the calibration data to the selected output device (see page 3–12), then returns to the Calibration menu.
Page 68
4–14
NOTES
Page 69
Model 5850v2 5–1
5. SPECIAL FUNCTIONS
CHAPTER 5
SPECIAL FUNCTIONS
The Model 5850v2 Gyratory Compactor firmware includes a number of functions that typically are not used on a day-to-day basis. These functions are accessed from the Special menu, which is a submenu of the Setup menu.
Page 70
5–2
SPECIAL MENU
The Special menu provides access to a number of functions that typically are not used on a day-to -day basis. These functions enable the operator to set the date and time, to clear all project (specimen) data, and to reset the software.
To access these functions, press 6 from the Setup menu. The compactor displays the Special menu shown below.
-Special- 1- Clock/Calendar 2- Erase Records 3- Reset Software
Use the arrow keys to scroll through the menu options. To select an option, press the numeric key that corresponds to the desired option. The following sections describe each selection.
Page 71
Model 5850v2 5–3
5. SPECIAL FUNCTIONS
CLOCK/CALENDAR
The compactor stores the gyration data for the last 20 specimens, using the date and times to identify each specimen. The time and date of compaction are downloaded with the data.
To set the current time and date, press 1 from the Special menu shown on page 5–2. The compactor displays the Clock/Calendar menu shown below. Use the arrow keys to scroll through the menu options. To select an option, press the numeric key that corresponds to desired option. The following sections describe each selection.
-Clock/Calendar- 1- Change Time 2- Change Date 3- Time Format
-Clock/Calendar- 4- Date Format
CHANGE TIME
To set the time, press 1 from the Clock/Calendar menu shown above. The compactor displays:
08:45 AM
Arrows toggle AM/PM
Input Time and
Press <ENTER>
Note that in this example, the time is displayed in AM/PM format. To change the format, see the Time Format section on page 5–5.
Page 72
5–4
The top line of the display shows the current clock setting. To accept this setting, press ENTER. The compactor returns to the Clock/Calendar menu. To change the clock setting, enter the current time using the numeric keys and press ENTER. The
compactor returns to the Clock/Calendar menu.
NOTE
The hour and minutes must be entered as two-digit numerals, with leading zeroes as required. For example, to set the time to 7:06, press 0 7 0 6, and then
press ENTER.
CHANGE DATE
To set the date, press 2 from the Clock/Calendar menu shown on page 5–3. The compactor displays:
04/08/2009 mm/dd/yyyy
Input Date and
Press <ENTER>
Note that in this example, the date is displayed in mm/dd/yyyy format. To change the format, see the Date Format section on page 5–5.
The top line of the display shows the current date setting. To accept this date and return to the Clock/Calendar menu, press ENTER. To change the date, enter the current date using the numeric keys and press ENTER. The compactor returns to the
Clock/Calendar menu.
NOTE
The month and day must be entered as two-digit numerals, with leading zeroes as required. The year must be entered as a four-digit numeral. For example, to set the date to April 8, 2009, press 0 4 0 8 2 0
0 9, then press ENTER.
Page 73
Model 5850v2 5–5
5. SPECIAL FUNCTIONS
TIME FORMAT
The compactor can display the time in either AM/PM or 24-hour format. To set the desired format, press 3 from the
Clock/Calendar menu shown on page 5–3. The compactor displays:
-Time Format­1- AM/PM 2- 24-Hour
Press the numeric key that corresponds to the desired time format. The compactor returns to the Clock/Calendar menu.
DATE FORMAT
The compactor can display the date in either mm/dd/yyyy or dd/mm/yyyy format, where mm = month, dd = day, and yyyy = year.
To set the desired format, press 4 from the Clock/Calendar menu shown on page 5–3. The compactor displays:
-Date Format­1- mm/dd/yyyy 2- dd/mm/yyyy
Press the numeric key that corresponds to the desired date format. The compactor returns to the Clock/Calendar menu.
Page 74
5–6
ERASE RECORDS
The Erase Records function erases all data records stored in the compactor’s memory. To erase data records, press 2 from the
Special menu shown on page 5–2. The compactor displays:
Permanently Erase all Data Records?
<YES> or <NO>
To erase all data records, press YES. The compactor restores
the default settings, displays a brief confirmation message, and returns to the Special menu.
To return to the Special menu without erasing the data records,
press NO/CE or ESC.
Page 75
Model 5850v2 5–7
5. SPECIAL FUNCTIONS
RESET SOFTWARE
The Reset Software function restores all software functions and settings to their default (factory) settings.
NOTE
The Reset Software function does not erase data records or calibration constants stored in the compactor memory.
To use this function, press 3 from the Special menu shown on page 5–2. The compactor displays:
System Reset Sets System Variables to Defaults! Continue?
<YES> or <NO>
To restore the default settings, press YES. The compactor
restores the default settings, displays a brief confirmation message, and returns to the Special menu.
To return to the Special menu without restoring the default
settings, press NO/CE or ESC.
Page 76
5–8
NOTES
Page 77
Model 5850v2 Appendix A–1
A. TROUBLESHOOTING
APPENDIX A
TROUBLESHOOTING AND SERVICE
This appendix contains information on servicing and maintaining the Model 5850v2 Gyratory Compactor.
Page 78
Appendix A–2
TROUBLESHOOTING
WARNING
To prevent personal injury or equipment damage, become familiar with the safety warnings on page 1–1 before operating the compactor.
Gyratory compactor does not turn on
11..
Ensure that the unit is plugged in.
22..
Check that the power switch is in the ON position.
33..
Ensure the Emergency Stop button is not engaged.
44..
Check the power to the wall outlet.
55..
Check that the fuse for the wall outlet is not blown or that the circuit breaker is not tripped.
Moving parts are not moving
11..
Ensure the unit is turned on.
22..
Check that the chamber door is closed.
33..
A switch may be broken. Check the service panels and emergency switches.
44..
Verify that the hydraulic oil in the reservoir is at the proper level, as described on page 1–12. Fill, if necessary, with light grade (ISO VG 32, SAE 10) hydraulic oil.
Gyration data does not download to the computer
11..
Check that the computer is properly connected to the compactor’s serial port.
22..
Check that the Auto Output feature is enabled (see page 3–11).
33..
Check that the serial port is specified as the output device (see page 3–12).
Page 79
Model 5850v2 Appendix A–3
A. TROUBLESHOOTING
Gyration data does not print automatically following a compaction cycle
11..
Ensure that the Auto Output feature is enabled (see page 3–11).
22..
Ensure that the proper output device is selected (see page 3–12).
Gyration data does not print or download properly
11..
Ensure that the Auto Output feature is enabled (see page 3–11).
22..
If printing or downloading data to a USB device, ensure that the device is compatible with the compactor. A list of compatible USB memory devices and printers is available on the 5850v2 product page at www.troxlerlabs.com/.
General calibration problems
11..
Check all cable connections.
22..
For the height calibration, ensure that the puck, specimen papers, and height standard assembly are located properly on the lower carriage plate.
33..
For the pressure calibration, ensure that the pucks and the load cell are located properly on the lower carriage plate.
44..
Repeat the calibration once. If you still have problems with the calibration, call your Troxler representative.
Compactor displays: Pressure Calibration Communication Error
11..
Check all connections between the compactor and the external load cell.
22..
Check the power connection to the load cell.
All other compactor error messages Record the error message, and then contact Troxler at
1.877.TROXLER (1.877.876.9537) for further information.
Page 80
Appendix A–4
GENERAL MAINTENANCE SCHEDULE
The following sections provide a recommended schedule for performing regular maintenance on the Model 5850v2 Gyratory Compactor.
CAUTION
Do not use a degreasing cleaner or glass cleaner to clean the clear chamber door. To prevent damage to the door surface, use a mild detergent only.
NOTE
Use any degreasing cleaner and a clean rag to clean metal parts. See the safety warnings on page 1–1.
DAILY, BEFORE USE
11..
Vacuum the mold tray and compaction chamber.
22..
Clean the mold tray, lower carriage plate (including the mold positioning pins), and ram head (see Figure 2–2, View A, on page 2–9), as well as the upper carriage assembly and upper puck plate (View B) with Bindoff or similar cleaner.
33..
Clean the mold and pucks with Bindoff or similar cleaner.
BEFORE EACH CYCLE
11..
If necessary, clean the mold tray, lower carriage plate (including the mold positioning pins), and ram head (see Figure 2–2, View A, on page 2–9), as well as the upper carriage assembly and upper puck plate (View B) with Bindoff or similar cleaner.
22..
Ensure that the exterior surface of the mold is free of dirt and asphalt residue.
33..
Lubricate the ram head with Magnalube-G.
44..
Inspect the upper puck plate. If dry, lubricate it with Magnalube-G.
Page 81
Model 5850v2 Appendix A–5
A. TROUBLESHOOTING
EVERY 80 HOURS OF OPERATION
11..
Wipe or scrape away any asphalt residue that has adhered to the mold tray, lower carriage plate, ram head, upper carriage assembly, or upper puck plate (see Figure 2–2, View A, on page 2–9)
22..
After cleaning, wipe the areas with a clean, dry cloth.
33..
Inspect the ram head. Check for pitting or chipping. If replacement is necessary, contact your Troxler representative.
44..
Check the following for excessive wear (damage beyond the point of operation) or damage:
Lower carriage plate and upper carriage assembly – Ensure
that the surface is reasonably flat. Check for deep gouges, pitting or chipping. If replacement is necessary, contact your Troxler representative.
Ram head – Ensure that the surface is reasonably flat.
Check for deep gouges, pitting or chipping. If replacement is necessary, contact your Troxler representative.
Mold positioning pins (in the lower carriage plate) – Check
for wear or flattening. Replace if necessary.
Pucks – Ensure that the surfaces are reasonably flat. Check
for pitting or chipping. Replace if necessary.
Mold – Check for pitting or chipping. Check upper and
lower flanges for wear (flat area wider than 0.2 inches). Replace if necessary.
Retaining ring (inside the bottom of the mold) – Ensure that
the ring is in place. If necessary, return the mold to Troxler for servicing.
55..
Remove the rear service panel and perform the following steps: Hydraulic oil level – Locate the fill level sight glass as
shown in Figure 1–2 on page 1–12. Ensure that the oil level is at the 30-degree mark on the sight glass, as shown in Figure 1–3 on page 1–13. If oil is needed, remove the reservoir fill cap (see Figure 1–2), place a funnel into the fill tube as shown in Figure 1–4, and add a light grade (ISO VG 32, SAE 10) hydraulic oil as necessary. Remove the funnel and replace the reservoir fill cap.
Page 82
Appendix A–6
NOTE
Use only a light grade (ISO VG 32, SAE 10) hydraulic oil to fill the hydraulic reservoir.
Hydraulic power unit – Examine all hoses and fittings for
leaks.
Hydraulic hoses and braided sleeve – Examine the hydraulic
hoses and their braided sleeves for wear. If the sleeve is worn through and the rubber hydraulic hose is worn, replace the hose and sleeve.
66..
Open the chamber door and examine each hydraulic hose for wear. If the rubber cover is worn, replace the hose.
EVERY 500 HOURS OF OPERATION OR ONCE A YEAR
11..
Remove the right-side service panel. Locate the hydraulic filter (see Figure A–1). Verify that the bypass indicator on the top of the filter housing is green. If the bypass indicator is red, the filter element must be changed. Contact your Troxler representative for more information.
Figure A–1. Hydraulic Filter Bypass Indicator
ENSURE
BYPASS INDICATOR
IS GREEN
Page 83
Model 5850v2 Appendix A–7
A. TROUBLESHOOTING
REPLACING THE BATTERIES
The compactor uses two AA batteries to maintain the real-time clock (date and time). To avoid loss of the real-time clock settings, replace the batteries at least once a year.
WARNING
Carefully note the polarity of the batteries when installing them in the battery holder. A battery may explode or leak if installed improperly.
The battery holder is located behind the control panel. To replace the batteries:
11..
Turn the power switch off and disconnect the ac power cord from the left side connector (see Figure 1–1 on page 1–7).
22..
Remove the four screws that secure the control panel.
33..
Carefully remove the control panel, using care not to damage any of the cables connected to it.
44..
The battery holder is located on the rear of the control panel. Note the polarity of the AA batteries.
55..
Remove the old batteries and install new AA batteries.
NOTE
If the new batteries are installed within approximately one minute after the old ones are removed, the real-time clock settings should be maintained.
66..
Install the control panel using the four screws removed in step 2.
77..
Reconnect the ac power cord and turn the power switch on.
88..
Verify that the compactor displays the current date and time. Reset, if necessary, as described on page 5–3.
Page 84
Appendix A–8
CLEANING THE COOLING FAN
1. Ensure Cooling Table Fan is powered down.
2. Pull Fan Assembly removal handle and extend fan assembly
REPLACEMENT PARTS
The list below shows part numbers for parts that are replaced often. Other replacement parts can be ordered by calling 1-877- TROXLER or visiting our online catalog at www.troxlerlabs.com.
PART # DESCRIPTION
106514 Cable, serial, 8-ft 110697 Cable, USB communications 110665 Gravity extruder 106989 Height standard assembly 116066 Mold assembly, 100 mm 116069 Mold assembly, 150 mm 116901 Model 5850v2 Manual of Operation and Instruction 108664 Power cord, 13 A, 10-ft 116220 Printer, 5850v2 106953 Specimen paper, 150 mm (1 package)
OPTIONAL ACCESSORIES
PART # DESCRIPTION
108706 Pressure Verification Kit 110062 Dynamic Angle Verification (DAV) II with HMS system 116089 Pneumatic Extruder 018141 Bindoff (1 gallon) 012786 Lubricant, Magnalube-G (1-lb can) 018290 Lubricant brush 018682 Heat-resistant gloves Call GyroImport Software and Operator Manual Call Shear Measurement Upgrade
Page 85
Model 5850v2 Appendix A–9
A. TROUBLESHOOTING
RETURNING PARTS FOR SERVICE
All shipments to the factory must be accompanied by a Returned Goods Authorization (RGA) number, and a description of the instrument, and its problem. This information is used by Troxler shipping and service personnel to expedite the repair work.
To obtain an RGA number, please call or fax the factory or branch office with your request. Please have the following information available when contacting Troxler for an RGA number:
Unit (or part) model and serial number. Part number/serial number (if applicable). Is the unit (part) still under warranty? Problem or difficulty you are having with the unit. Shipment method to Troxler and for return shipment. Shipping and billing address (not P.O. Box) – street address and
zip.
Telephone number/contact (for questions from Troxler). Will an estimate be required prior to performing any work on
the part?
Payment method: credit card, account number, or purchase
order number. All government agencies (city, county, state, and federal) are required to send purchase order numbers.
NOTE
To prevent order duplication, if an order has been
placed by telephone, please write “Confirming Order”
on any follow-up written requests.
Page 86
Appendix A–10
NOTES
Page 87
Model 5850v2 Appendix B–1
B. MENU MAP
APPENDIX B
MENU MAP
This appendix provides a map of the menus in the Model 5850v2 Gyratory Compactor control software.
Page 88
Appendix B–2
MENU MAP DESCRIPTION
Figure B–1 is a map of the compactor’s Setup menu and each of its submenus. To access the Setup menu, press Setup. Where
applicable, the default (as shipped) menu settings are shown in shaded text.
The menu map uses indentation to indicate submenus that result from selection of a menu item. For example, the first eight lines of Figure B–1 are:
-Setup­1– View Settings 2- Change Settings
-Change Settings­1- Operation Mode
-Operation Mode­1- # Gyrations 2- Specimen Height
This indicates that the first two menu items under the –Setup- menu are View Settings and Change Settings. When the
Change Settings item is selected, the compactor displays the Change Settings submenu.
The first menu item under the Change Settings submenu is Operation Mode. When this item is selected, the compactor
displays the Operation Mode submenu, which has two menu items, # Gyrations and Specimen Height.
NOTE
The menu map contains only the displays that allow or require a choice by the operator. Other displays (such as numerical entries, status information, confirmation messages, or error displays) are not included.
Page 89
Model 5850v2 Appendix B–3
B. MENU MAP
Figure B–1. Model 5850v2 Menu Map
-Setup­1– View Settings 2- Change Settings
-Change Settings­1- Operation Mode
-Operation Mode-
1- # Gyrations
2- Specimen Height
2- # of Gyrations
3- Height 4- Angle 5- Pressure 6- Mold Diameter
-Mold Diameter-
1- 150mm
2- 100mm
3- 4in
7- Post Gyrate Delay
-Post Gyrate Delay-
1- Enable
2- Disable
3- Data Output
-Data Output­1- Output Record 2- Auto Output 3- Output Device
-Output Destination-
1- Serial Port
2- USB Printer
3- Thumb Drive
4- Output Format
-Output Format-
1- Table
2- Formatted
3- GyroPave
4- Home Position
Page 90
Appendix B–4
Figure B–1. Model 5850v2 Menu Map (Continued)
-Setup­5- Calibration
-Calibration­1- Pressure 2- Height 3- Angle Offset 4- Print Calibration
6- Special
-Special­1- Clock/Calendar
-Clock/Calendar­1- Change Time 2- Change Date 3- Time Format
-Time Format­1- AM/PM 2- 24-Hour
4- Date Format
-Date Format­1- mm/dd/yyyy
2- dd/mm/yyyy 2- Erase Records 3- Reset Software
Page 91
Model 5850v2 Appendix C-1
C. SPECIFICATIONS
APPENDIX C
SPECIFICATIONS
This appendix provides environmental conditions and specifications for the Model 5850v2 Gyratory Compactor.
CONTENTS
Environmental Conditions ............................................................ C–2
Electrical Specifications ............................................................... C–3
Mechanical Specifications ............................................................ C–4
Page 92
Appendix C–2
ENVIRONMENTAL CONDITIONS
Ambient Storage –55 to 85 C Temperature (–67 to 185 F)
Ambient Operating 10 to 50 C Temperature (50 to 122 F)
Altitude Rating 2000 meters maximum
Main Supply Voltage 10% Fluctuation
Pollution Degree 2 Installation Categories II
(Overvoltage Categories) Humidity 92% maximum
Page 93
Model 5850v2 Appendix C-3
C. SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
Power Requirements: 120 V units 120 VAC (±10%), 12 A, 60 Hz
240 V units 240 VAC (±10%), 6 A, 50/60 Hz, Single Phase
Serial Port: Connector 9-pin male D-subminiature connector
RS-232 standard
Data format 8 data bits, 1 stop bit, no parity Baud rate 9600 Cable type RS-232 null modem
9-pin female – 9 (25) pin female
USB Port A list of compatible USB memory
devices and printers is available on the 5850v2 product page at www.troxlerlabs.com.
Modes of Operation Compact to operator-specified number of
gyrations or specimen height
Data Acquisition Gyration number, specimen height
(to nearest 0.1 mm), angle of gyration, shear value (optional)
Unit of Measure SI Units
Internal Data Storage Results from 20 tests stored in memory
Page 94
Appendix C–4
MECHANICAL SPECIFICATIONS
Size 162.6 H x 71.1 D x 68 W cm (64 H x 28 D x 26.75 W in.)
Weight Approximately 227 kg (500 lb) Shipping Weight (est.) 328.8 kg (725 lb)
Unit with Packaging
Shipping Weight, (est.) 487.6 kg (1075 lb)
with All Accessories Mold Weight 11.6 kg (25.5 lb)
Puck Weight 3 kg (6.6 lb) Compaction Pressure 200 – 1000 kPa (29 – 145 psi)
Pressure Accuracy Meets or exceeds FHWA
specifications
Number of Gyrations Adjustable from 1 – 999
Angle of Gyration 0.00 – 3.0 0.02 degrees
Internal or external Mold Dimensions 150 mm ID x 317.5 mm height
(100 mm and 4 in. ID also available)
50.0 mm minimum specimen height
Maximum Mold 175 C (350 F) Temperature
Speed of Gyration 30 ± 0.5 gyrations/minute
Hydraulic Oil Light grade (ISO VG 32, SAE 10)
hydraulic oil
Page 95
Model 5850v2 Index
INDEX
A
Accessories ................................................................................... 1–8
Altitude rating ...............................................................................C–2
Ambient temperature ....................................................................C–2
American Society of Testing and Materials (ASTM) ................... 1–6
Angle............................................................................. 1–5, 3–6, C–4
Offset .............................................................................. 4–2, 4–12
Verification ....................................................................... 4–2, 4–3
Arrow keys .................................................................................... 2–2
Assembly .................................................................................... 1–12
Auto output ................................................................................. 3–11
Automatic mode .......................................................................... 2–15
Batteries, replacing ...................................................................... A–7
Baud rate .......................................................................................C–3
Bindoff ...................................................................... ii, 2–8, 4–6, 4, 8
Cable
Serial ......................................................................................... 1–8
USB........................................................................................... 1–8
Calibration .................................................................................... 4–1
Calibration constants ............................................ 4–10, 4–12, 5–7
Menu ......................................................................................... 4–5
Pressure ............................................................................. 4–2, 4–6
Print......................................................................................... 4–13
Problems .................................................................................. A–3
Schedule .................................................................................... 4–2
Specimen height .............................................................. 4–2, 4–10
Centers, service ................................................................................ iii
Change settings ............................................................................. 3–4
Cleaning and lubricating ............................................................... 2–8
Clock/Calendar ............................................................................. 5–3
Compaction
Pressure ............................................................................. 1–5, C–4
Specimen................................................................................. 2–15
Control panel ........................................................................ 1–8, 2–2
Data output .................................................................................. 3–10
Destination .............................................................................. 3–12
Device ..................................................................................... 3–12
Date
Change ...................................................................................... 5–4
Format ....................................................................................... 5–5
Page 96
Index
Decimal key ................................................................................... 2–2
Destination, data output ............................................................... 3–12
Dynamic Angle Verification (DAV) device ........................ 4–3, 4–12
Electrical specifications ................................................................ C–3
EMERGENCY switch ........................................................... 1–4, 2–2
Environmental conditions ............................................................. C–2
Erase records ................................................................................. 5–6
Error messages ............................................................................. A–3
ESC key ......................................................................................... 2–2
Fluctuation, supply voltage .......................................................... C–2
Full table output format ............................................................... 3–10
Gyration
Angle ........................................................................ 1–5, 3–6, C–4
Number ............................................................................. 3–5, C–4
GyroImport .................................................................................. 3–12
GyroPave ..................................................................................... 3–13
Height standard assembly .................................................... 1–8, 4–11
Height versus gyration format ..................................................... 3–10
Height, specimen ........................................................................... 3–6
Home position ............................................................................. 3–14
Humidity ....................................................................................... C–2
Hydraulic oil ..................................................... 1–12, C–4, A–5, A–2
Inspection ...................................................................................... 1–9
Installation categories ................................................................... C–2
Keypad .......................................................................................... 2–2
Kit, pressure verification ....................................................... 1–8, 4–6
Loading specimen........................................................................ 2–13
Maintenance schedule .................................................................. A–4
Mechanical specifications ............................................................ C–4
Menu map ..................................................................................... B–1
Mold
Assembly ................................................................................... 1–8
Diameter .................................................................................... 3–7
Maximum temperature ............................................................. C–4
NO/CE key .................................................................................... 2–2
Number
Gyrations .......................................................................... 3–5, C–4
Keys ........................................................................................... 2–2
Offset, angle ................................................................................ 4–12
Oil, hydraulic .................................................... 1–12, C–4, A–5, A–2
Operating temperature .................................................................. C–2
Operation mode ............................................................................. 3–5
Page 97
Model 5850v2 Index
Optional accessories .................................................................... A–8
Output
Auto ........................................................................................ 3–11
Destination .............................................................................. 3–12
Device ..................................................................................... 3–12
Full table format ..................................................................... 3–10
GyroPave ................................................................................ 3–13
Height versus gyration format ................................................ 3–10
Record ..................................................................................... 3–11
Papers, specimen ................................................................. 1–8, 2–11
Parts ..................................................................................... 1–8, A–8
Returning ................................................................................. A–9
Port
Serial ....................................................................... 1–3, 1–14, C–3
USB......................................................................... 1–3, 1–14, C–3
Power
Requirements ............................................................................C–3
Switch ............................................................................... 1–8, 2–4
Pressure ......................................................................................... 3–7
Accuracy ...................................................................................C–4
Calibration ........................................................................ 4–2, 4–6
Compaction ....................................................................... 1–5, C–4
Verification kit .................................................................. 1–8, 4–6
Print Calibration .......................................................................... 4–13
Printer ........................................................................................... 1–8
Puck .............................................................................................. 1–8
Ram
Pressure ..................................................................................... 3–7
Replacement parts ........................................................................ A–8
Replacing batteries ....................................................................... A–7
Reset software ............................................................................... 5–7
Returning parts ............................................................................. A–9
Safety Warnings ............................................................................ 1–2
Schedule, maintenance................................................................. A–4
Serial
Cable ......................................................................................... 1–8
Port .......................................................................... 1–3, 1–14, C–3
Service centers ................................................................................. iii
Settings
Change ...................................................................................... 3–4
View .................................................................................. 3–2, 3–4
Setup ............................................................................................. 3–2
Page 98
Index
SETUP key .................................................................................... 2–2
Shear ............................................................................................ 2–17
Output ...................................................................................... 3–12
Size ............................................................................................... C–4
Software, GyroImport ................................................................. 3–12
Software, GyroPave ..................................................................... 3–13
Software, reset ............................................................................... 5–7
Special functions ........................................................................... 5–2
Specifications ............................................................................... C–1
Electrical ................................................................................... C–3
Mechanical ............................................................................... C–4
Specimen
Compaction ............................................................................. 2–15
Height ........................................................................................ 3–6
Height calibration ............................................................ 4–2, 4–10
Loading .................................................................................... 2–13
Papers .............................................................................. 1–8, 2–11
Preparing ................................................................................. 2–11
START key ................................................................................... 2–2
Storage temperature ...................................................................... C–2
Supply voltage fluctuation ............................................................ C–2
Switch, EMERGENCY ......................................................... 1–4, 2–2
Switch, power ........................................................................ 1–8, 2–4
Target height.................................................................................. 3–6
Temperature
Mold ......................................................................................... C–4
Operating .................................................................................. C–2
Storage ...................................................................................... C–2
Time
Change ....................................................................................... 5–3
Format ....................................................................................... 5–5
Troubleshooting............................................................................ A–2
Unpacking ................................................................................... 1–10
USB
Cable .......................................................................................... 1–8
Port ......................................................................... 1–3, 1–14, C–3
Verification, angle ................................................................. 4–2, 4–3
View settings ................................................................. 2–5, 3–2, 3–4
Weight .......................................................................................... C–4
YES key ......................................................................................... 2–2
Page 99
Model 5850v2 Index
Page 100
NOTES