Tripp-Lite SU8000RT4U Catalog Page

SmartOnline 208/240 & 120V 8kVA 5.6kW
Highlights
8000VA / 8kVA / 5600W on-line
double-conversion UPS
208/120V or 240/120V +/-3%
output at 60Hz
Included maintenance bypass
switch enables live replacement
of UPS with zero downtime
4U Rack/Tower compatible,
Hot-swap power and battery
modules
USB, RS232 & EPO ports,
Network management card
options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (4 wire), L6-30R,
L6-20R, 5-15/20R & Hardwire
outputs
Package Includes
SU8000RT4U Smart Online UPS
SUPDM8K Detachable PDU with
Manual Bypass Switch
PowerAlert software and
complete cabling
4 post rackmount installation
brackets
Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch
MODEL NUMBER: SU8000RT4U
Description
Tripp Lite 8kVA SmartOnline Hot-Swappable Modular Rack/Tower UPS offers 8000VA on-line,
battery-derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass
prevents unexpected service interruptions during overload or internal fault conditions. Single all-in-one housing
installs in 4 rack spaces(4U). Upright tower and two post rackmount installation supported with optional
accessories. Maintains full-time sine wave output within 3% of selectable 208/120 or 240/120V AC. Corrects
brownouts and overvoltages from 65V to 140V(L-N). Expandable runtime with optional external battery packs.
Converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC output with
enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems
not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat
output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include combination DB9 RS-232 enabled and dry
contact serial port, enhanced USB port and slot for network management card options, such as Tripp Lite's SNMPWEBCARD network interface.
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports
simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert
monitoring software and complete cabling. Supports Emergency Power Off(EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls
support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in rackmount or tower configurations. Split phase 4
conductor hardwire input. UPS supported outlets include two L6-30R, two L6-20R and 4 low voltage 5-15/20R. Hardwire output is also supported. Hardwire
connections and outlets are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off
connected equipment. Internal batteries and optional external battery packs are field replaceable and hot swappable. Attractive all-black color
scheme.$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only).
Features
True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
8000VA/5600 watt output power capacity with dual voltage output of 208/120 or 240/120V
4U all-in-one high power density housing supports rackmount installation in only 4 rack spaces
Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Hardwire input/output connections and output receptacles are mounted on a detachable backplate with manual bypass switch to enable hot-swappable
UPS replacement without powering off connected equipment
Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical
servers, networking and telecommunications equipment
Maintains output within 3% of selected 208/120 or 240/120V nominal voltage during brownouts and overvoltages
Supports connected equipment during blackouts for 12/5 minutes at half/full load levels, runtime is further expandable with optional external battery packs
Intelligent battery management system extends battery life
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software(see manual)
Network interfaces support simultaneous communications via DB9 port, USB port and slot for network management card options, such as Tripp Lite's
SNMPWEBCARD network interface
DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto
shutdown features of Windows and Mac OS X.
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number
of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
Built-in Emergency Power Off(EPO) interface with cable
Includes hardwire output and 8 output receptacles(2 L6-30R, 2 L6-20R, 4 NEMA 5-15/20R), all of which are available for simultaneous use
Split phase, 4 conductor hardwire connection(featured on included detachable PDU).
Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions
Front panel switches enable power on/off control, self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures
Optional 2-9USTAND set of tower stands supports upright tower installation
Optional 2POSTRMKITHD accessory enables 2 post rackmount installation
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only)
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 8000
Output kVA Capacity (kVA) 8
Output Watt Capacity (Watts) 5600
Output kW Capacity (kW) 5.6
Output Capacity Details
Power Factor 0.7
8,000VA / 5600W (240V), 7200VA / 5600W (208V); Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared
Loading...
+ 4 hidden pages