Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU8000RT3UN50
SmartOnline Expandable Rack/Tower UPS System- Special version of SU8000RT3U with twist-lock 50A input
plug
Highlights
8000VA (8kVA) on-line 6U rack/tower UPS with expandable runtime (3U
power module + 3U battery pack) with twist-lock 208/240V 50A input plug
Zero transfer time, on-line, double-conversion and economy-mode operation
supported
Detachable PDU with manual bypass switch enables hot-swap UPS
replacement without powering off connected loads
200/208/230/240V selectable input/output voltage
2% output voltage regulation over an input voltage range of 156V to 276V
Enhanced serial communications ports, SNMP/Web Card Slot and EPO
interfaces
$250,000 Ultimate Lifetime Insurance (USA, Puerto Rico & Canada only).
Description
8000VA (8kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 6 rack
spaces (3U power module and 3U battery pack). Maximum installed rack depth of 32.5 in. Expandable battery runtime with optional external battery
packs. Full-time sine wave 200, 208, 220, 230, or 240V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back
to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 156V and overvoltages to
276V. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Includes Hubbell twist-lock 208V 50A
input plug for simple installation; NEMA L6-30R and L6-20R output receptacles. Detachable input-output PDU module with manual bypass switch
enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero
transfer time between AC and battery operation. Network management interfaces support communications via RS-232, contact-closure port and
optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via network
interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs offer
at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power
status. LCD panel with scroll buttons offers detailed diagnostic test information at startup and during self tests, plus real-time data on input and
output voltage, frequency (Hz), load percentage and battery charge level. LED/LCD display panel easily rotates for viewing in rackmount or tower
configurations. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included;
2POSTRMKITWM 2-post rackmount hardware accessories available. Field replaceable, hot-swappable power module and external battery packs.
Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
Applications
Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection. Common
applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems
Package Includes
3U power module with detachable hot-swap PDU input/output panel and bypass switch
3U external battery pack