Model #: SU6000RT4UHV
Highlights
Completely user hot-swappable—no service call or technician needed
Protects rackmount servers, telecom systems and other networking
equipment in high-voltage environments with true on-line operation, pure sine
wave output and zero transfer time
4 AC outlets (2 L6-20R; 2 L6-30R) with 200/208/220/230/240V 50/60Hz output
6kVA/5400W capacity in 4U form factor with power module and independent,
detachable PDU
Hot-swappable power and battery modules
8.5-minute half-load runtime, 2-minute full-load; expandable runtime with
external battery packs
Front panel LEDs with detailed LCD monitoring and control screen
USB, RS232 and SNMP communication ports with included PowerAlert
software for complete network power management and control
$250,000 Ultimate Lifetime Insurance; 2-year warranty
Description
Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHV provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHV has a 6kVA/5400W capacity and 4 AC outlets (2 L6-20R; 2 L6-30R).
With its detachable PDU, the SU6000RT4UHV is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.
UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHV‘s runtime can be expanded with optional external battery packs.
The SU6000RT4UHV features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.
An LCD display with LED indicators enables IT personnel to monitor operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.
The SU6000RT4UHV features a USB port and a DB9 port that, when used with Tripp Lite's included PowerAlert software, provide comprehensive network power monitoring and control. An optional SNMPWEBCARD accessory can enable the UPS to operate as an IP managed device.
The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.
The SU6000RT4UHV comes with $250,000 Ultimate Lifetime Insurance coverage for connected equipment and a 2-year warranty.
Features
Tripp Lite SU6000RT4UHV 6000VA / 6kVA / 5400 watt online, double-conversion UPS system in a single 4U rack/tower compatible housing (at 208V nominal, output is limited to 4992 watts) Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions Detachable back panel PDU contains input line cord connection and output receptacles, plus manual bypass switch to support
hot-swappable whole UPS replacement with no interruption to connected equipment L6-30P input plug; two L6-30R and two L6-20R outlets Included rail kit supports 4U 19 inch rackmount installation in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHV) Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHV) Maximum installed rack depth of only 20.7 in. / 52.6cm Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode Corrects brownouts to 156V at full load (100V at 50% load or less) Corrects overvoltages to 290V at full load (300V at 90% load or less) Supports 50/60Hz operation for worldwide frequency compatibility Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network-grade AC surge and noise suppression Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD) Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED/LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off (EPO) via built-in interface Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement BP192V12-3U external battery packs are field replaceable and hot swappable Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) Frequency conversion mode enables conversion of 60Hz to 50Hz or 60Hz to 50Hz (no de-rating)
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
6000
Output kVA capacity (kVA)
6.0
Output Watt Capacity (watts)
5400
Output kW capacity 5.4
Output power factor 0.9
Output Capacity Details
Output capacity de-rates to 4992 watts when used at 208V nominal
Crest Factor 3:1
Nominal Output Voltage(s) Supported
200V; 208V; 220V; 230V; 240V
Frequency compatibility
50/60 Hz (auto-selectable)
Frequency compatibility details
Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output voltage regulation (line mode)
+/- 2%
Output voltage regulation (Economy line mode)
+/- 10%
Output voltage regulation (Battery mode)
+/- 2%
Built-in UPS output receptacles
2 L6-20R outlet(s); 2 L6-30R outlet(s)
Output receptacle details
Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
Output circuit breaker 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered
Output AC waveform (AC mode)
Pure Sine wave
Output AC waveform (battery mode)
Pure Sine wave
INPUT
Rated input current (at maximum load)
31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
Nominal Input Voltage(s) Supported
200V AC; 208V AC; 220V AC; 230V AC; 240V AC
Nominal input voltage description
Factory configured to 208V
UPS input connection type
L6-30P
UPS Input cord length (ft.)
10
UPS Input cord length (m)
3
Recommended Electrical Service
30A
BATTERY
Full load runtime (minutes)
2 minutes (5400 watts)
Half load runtime (minutes)
8.5 minutes (2700 watts)
Expandable battery runtime
Runtime is expandable with external battery packs
External battery pack compatibility
BP192V12-3U; BP192V557C-1PH; BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH
DC system voltage (VDC)
192
Loading...