SmartOnline 208 & 120V 5kVA 3.5kW DoubleConversion UPS, 7U, Extended Run, Network Card
Slot, DB9 Serial
MODEL NUMBER: SU5000RT3U
Description
Tripp Lite 5kVA Smart Online Rack / Tower UPS. 5000VA online, double-conversion UPS for server,
network and telecommunications equipment. Maintains battery-derived AC output during blackouts with
active, full-time power conditioning. Fault-tolerant auto-bypass prevents unexpected service interruptions
during overload or internal fault conditions. 3U power module, 2U transformer module and 2U battery pack
install in 7 rack spaces. Full-time sine wave output within 2% of selectable 208V and simultaneous 120V
AC. Corrects brownouts to 156V and overvoltages to 276V. Frequency regulation locks output power to
50/60Hz (+/-0.2%). Expandable runtime with optional rackmount external battery packs. Dual-conversion
UPS converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced
protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not
addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU
heat output and energy costs. Network-grade AC surge and noise suppression. Network management
interfaces include 2 DB9 ports and slot for network management card options. Supports simultaneous
detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network
interfaces. PowerAlert UPS monitoring and auto shutdown software is available via free download. Front
panel LEDs and LCD readout with scroll controls support visual monitoring of all major UPS functions.
Audible alarm. Self test. 4-post rackmount accessories included; 2-9USTAND and 2POSTRMKITHD
accessories available. L6-30P plug-in connection; built-in output receptacles include two L6-30R, two L6-
20R and twelve 5-15/20R. Power Distribution Unit (PDU) options supported. Field-replaceable, hot-
swappable external battery packs.
Highlights
●
5000VA / 5kVA / 3500W on-line
double-conversion UPS
●
208/120V 60Hz output, high
efficiency economy mode option
●
7U Rack/Tower compatible; Hot-
swappable batteries
●
RS232 & EPO ports; slot for
network management card
options
●
Front panel LEDs with detailed
LCD monitoring and control
screen
●
Expandable runtime with
optional external battery packs
●
NEMA L6-30P input (3 wire); L6-
30R, L6-20R & 5-15/20R
outputs
Package Includes
●
SU5000RT3UPM UPS Power
Module
●
BP240V5RT2U Battery Pack
●
SU5000XFMRT2U Step-down
Transformer
●
DB9 and EPO Cabling
●
4-post rackmount installation
accessories
●
Instruction manual
Features
●
True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges,
voltage fluctuations and line noise
●
5000VA/3500 watt output power capacity with dual high/low voltage output compatible with 200-240V
1 / 7
and 120V applications simultaneously
●
3U power module, 2U transformer module and 2U battery pack installs in any 19 inch rack enclosure
using only 7 rack spaces
●
Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC
output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-
solve power problems not addressed by other UPS types
●
Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency
variation for the most efficient operation of critical servers, networking and telecommunications
equipment
●
Accepts input voltages between 156 and 276, regulating output within 2% of 208 - plus 120V nominal
voltage
●
Supports connected equipment during blackouts for 20/8 minutes at half/full load levels, runtime is
further expandable with optional external battery packs
●
Intelligent battery management system extends battery life
●
Network interfaces support simultaneous communications via 2 DB9 ports and slot for network
management card options
●
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX,
SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
●
Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software,
available via FREE download from www.tripplite.com/poweralert
●
Built-in Emergency Power Off (EPO) interface with cable
●
Includes 17 built-in output receptacles (3 L6-30R w/one L6-30R used for transformer connection, 2 L6-
20R, 12 NEMA 5-15/20R)
●
L6-30P input plug-in connection
●
Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS
functions and current site electrical conditions
●
Front panel switches enable power on/off control, self-test and alarm cancel functions
●
Included adjustable mounting rails support installation in 4 post 19 inch rack enclosures, optional
2POSTRMKITHD supports 2 post rackmount installation
●
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Specifications
OVERVIEW
UPC Code 037332123534
UPS Type On-Line
INPUT
2 / 7
Rated input current (Maximum Load) 24A (208V)
Nominal Input Voltage(s) Supported 208V AC
UPS Input Connection Type L6-30P
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Recommended Electrical Service 30A 208V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 5000
Output kVA Capacity (kVA) 5
Output Watt Capacity (Watts) 3500
Output kW Capacity (kW) 3.5
Output Capacity Details Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30
seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as the overload is cleared
Power Factor 0.7
Crest Factor 3:1
Nominal Voltage Details This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer
supports 120V output
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Output frequency matches input nominal on startup
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation
(Economy Line Mode)
Output Voltage Regulation (Battery
Mode)
+/- 2%
+/- 10%
+/- 2%
Output Circuit Breakers 20A breakers (x4) on transformer module protect 3 5-15/20R outlets each, 20A breaker on power module protects
L6-20R outlets, L6-30R outlets are unbreakered
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery
Mode)
Nominal Output Voltage(s)
Supported
Pure Sine wave
120V; 208V
Output Receptacles (12) 5-15/20R; (2) L6-20R; (2) L6-30R
Individually Controllable Load Banks No
BATTERY
Full Load Runtime (min.) 8 min. (3500w)
Half Load Runtime (min.) 20 min. (1750w)
3 / 7