Tripp-Lite SU40K Catalog Page

SmartOnline 40kVA Modular 3-Phase UPS System,
Highlights
40,000 VA (40kVA) tower UPS
with 2 hot-swappable power
modules
N+1 redundant modular
architecture helps assure 100%
availability
1+1 parallel capability allows for
system redundancy or increased
capacity
Low THDi saves installation costs
by permitting 1:1 generator sizing
3-phase hardwire
(120/208VAC)input/output. Wide
input voltage correction range
(94-150V AC/163-260V AC)
On-line, double-conversion
operation with zero transfer time;
IGBT technology; extremely
efficient operation (up to 96%)
Runtime is expandable via
external battery cabinet options
Package Includes
SU40K UPS System
PowerAlert Software and cabling
Parallel cable (for 1+1 operation)
Instruction manual and startup
checklist
Warranty information
On-line Double-Conversion UPS for North America
MODEL NUMBER: SU40K
Description
Tripp Lite's SU40K(40kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line UPS System provides 100%
system availability with N+1 modular architecture and 1+1 parallel capability. In an N+1 configuration, the SU40K
provides two self-contained, redundant 20kVA power modules that can be hot-swapped(with the load powered) if
redundancy(two 40kVA models supporting a 40kVA load) or to increase capacity(two 40kVA models supporting
an 80kVA load). The SU40K provides mission-critical equipment with the highest level of power protection
available. Large capacity 40,000VA/32,000W UPS continually converts incoming AC power into filtered DC
power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine
wave output with zero transfer time assures compatibility with all equipment types. The SU40K's high input power
factor, advanced IGBT inverter technology and Digital Signal Processor(DSP) technology produce less than 3%
input Total Harmonic Distortion(THDi). With low THDi, generators run cooler and last longer, allowing managers
to save installation costs by installing a generator with a capacity equal to the equipment load(1:1 ratio).
Extremely efficient operation(up to 96%) saves money by lowering electricity consumption. Hardwire input and output connections support a variety of
permanent or PDU-style power connections. The SU40K features 120/208V AC, 3-phase, 4-wire(plus ground), wye input and output. It also features a wide
input voltage correction range: 94-150/163-260V AC. Frequency is 50 or 60 Hz(auto-selectable). The SU40K combines internal power and battery components
in a single small-footprint tower module. Typical half-load/full-load runtimes are 13 min./5.5 min. Battery runtime can be extended with optional stand-alone
hardwired external battery modules BP480V26B and BP480V40C with matching battery cabinets, available separately. Additional battery cabinets for extended
runtime solutions also available; contact Tripp Lite for more information. A manual bypass breaker and an automatic bypass function ensure 100% availability
of connected equipment by safely passing through AC power if the UPS requires maintenance. A built-in RS-232 communication port works with included
PowerAlert Software to provide shutdown commands and reporting on a single server. An accessory slot accepts an optional internal SNMPWEBCARD for
remote shutdowns, reboots and more. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions. The LCD
display includes a real-time event log screen with up to 500 events listed. A dynamic battery management screen optimizes battery function to lengthen
service life and allows cold restart of the UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency
Power Off button turns the UPS output OFF and disables Bypass output. Built-in Emergency Power Off(EPO) dry-contact interface supports remote
emergency shutdown in large facilities. A start-up service program is recommended to enhance the reliability of the installation.
Features
N+1 configuration: two self-contained, redundant 20kVA power modules can be hot-swapped with the load powered if maintenance is required
1+1 configuration: two SU40K models connected in parallel provide fail-safe redundancy or increased capacity
High input power factor, advanced IGBT inverter technology and Digital Signal Processor(DSP) technology produce low input Total Harmonic
Distortion(THDi)
Low THDi(less than 3%) saves installation costs by allowing 1:1 generator sizing
Extremely efficient operation(up to 96%) saves money by lowering electricity consumption
True on-line, double conversion UPS with IGBT technology provides pure sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
40,000VA/32,000W power capacity with 3-phase, hardwire 120/208VAC input/output connections
Features a wide input voltage correction range: 94-150/163-260VAC
Precision +/-1% output voltage regulation
Internal power and battery components are combined in a single small-footprint tower module. Typical half-load/full-load runtimes are 13 min./5.5 min.
Battery runtime can be extended with optional stand-alone hardwired external battery modules(Models BP480V26B and BP480V40C) with matching
battery cabinets, available separately from Tripp Lite
Additional battery cabinets for extended runtime solutions also available; contact Tripp Lite for more information
Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS
Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server
Accessory slot accepts an optional internal SNMP card(Model: SNMPWEBCARD) for remote shutdowns, reboots and more
Emergency Power Off button turns UPS output OFF and disables Bypass output
Built-in Emergency Power Off(EPO) dry-contact interface supports remote emergency shutdown in large facilities
Start-up service program is recommended to enhance the reliability of the installation
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 40000
Output kVA Capacity (kVA) 40
Output Watt Capacity (Watts) 32000
Output kW Capacity (kW) 32
Power Factor 0.8
Crest Factor 3:1
Nominal Output Voltage(s) Supported
Frequency Compatibility 50 / 60 Hz
Output Voltage Regulation (Line Mode)
Output Voltage Regulation (Battery Mode)
120/208V 3-PH Wye
+/- 1%
+/- 1%