Do you need to protect medium- to large-size servers, networking equipment and telecom systems against data
loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges? Tripp
Lite’s SU2200XLCD SmartOnline® Tower UPS System is the solution! Featuring a 2200VA/1800W capacity and
true on-line operation with pure sine wave output and zero transfer time to battery, it provides the highest level of
power protection for mission-critical equipment. The SU2200XLCD’s large internal battery set supports
connected equipment during blackouts, and runtime is expandable with optional external battery packs
BP48V24-2U(limit 1), BP48V60RT-3U(multi-pack compatible) and BP48V27-2US(multi-pack compatible), sold
separately. The SU2200XLCD has 7 AC outlets(6 5-15/20R, 1 L5-20R), including 2 load banks of 3 outlets each
that are individually controllable to reboot select equipment on demand or maximize battery runtime for mission-critical equipment. USB and DB9
communication ports support messaging of detailed UPS operational parameters and line power status. Included PowerAlert power management software
supports an unlimited number of network UPS systems. The SU2200XLCD also accepts an optional network management card options, such as Tripp Lite's
SNMPWEBCARD network interface. It comes backed by$250,000 of Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only).
Features
Ideal for Protection of Mission-Critical Equipment
The SU2200XLCD provides true on-line operation, reliable battery backup and comprehensive power management capability in a compact tower form factor.
Featuring a 2200VA/1800W capacity, 7 AC outlets(6 5-15/20R, 1 L5-20R), a 10-ft. cord with 5-20P plug, USB/DB9 ports and a slot for an optional network
management card option, the SU2200XLCD offers a complete power protection solution for medium- to large-size servers, storage devices, telecom systems
and other mission-critical equipment.
True On-Line Operation with Pure Sine Wave Output and Zero Transfer Time
The SU2200XLCD provides the highest level of protection available for mission-critical equipment. It actively converts raw incoming AC power to DC, then
re-converts it back to regulated, filtered AC output with a pure sine wave, completely isolating connected components from all power problems. Zero transfer
time between AC and battery operation maintains continuous output and further protects connected equipment from the disruptive effects of blackouts and
severe low-voltage conditions. Sine wave output guarantees compatibility with all equipment types.
Individually Controllable Outlets
The SU2200XLCD includes 2 load banks of 3 outlets each that are individually controllable via a software interface for remote reboot of locked-up equipment
or load shedding to maximize battery backup time for mission-critical equipment.
Reliable, Expandable Battery Backup
UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system
shutdown in case of a prolonged blackout. The SU2200XLCD features a large internal battery set that provides 13 minutes of battery support for a half
load(900 watts) and 4.5 minutes for a full load(1800 watts). During normal operation, incoming utility power keeps the UPS battery fully charged so that
backup power will always be available if needed. Intelligent battery management system extends battery life. For mission-critical applications demanding
continuous uptime, the fully scalable SU2200XLCD can provide expandable runtime with optional external battery packs BP48V24-2U(limit 1),
BP48V60RT-3U(multi-pack compatible) and BP48V27-2US(multi-pack compatible), sold separately.
High Power Factor and Highly Efficient Operation Reduces BTU Output
The SU2200XLCD features a high 0.82 power factor and an optional, highly efficient economy mode setting that can significantly reduce a facility’s energy
costs. In economy mode, the UPS operates with 97% efficiency, minimizing heat output, reducing cooling requirements and consuming less electricity.
AC Line and Tel/Ethernet Surge Suppression
A sudden power surge or spike can damage or destroy electronic components and wipe out irreplaceable data. The SU2200XLCD features a 570-joule surge
suppression rating to protect connected components and data from the harmful effects of power surges. One set of tel/Ethernet(RJ45) jacks provides surge
protection for a standard phone or network connection(cable not included).
EMI/RFI Line Noise Filtering
Various electrical and radio sources can cause disruptive interference on the AC line. This line noise is a common cause of incremental hardware damage,
data corruption and audio/video performance problems. The SU2200XLCD incorporates technology that filters out disruptive line noise, preventing it from
affecting your equipment.
LCD Screen and Audible Alarm
The SU2200XLCD features a front-panel LCD screen that enables IT personnel to monitor line power, on-line mode, bypass mode, on-battery, overload,
battery low, replace battery and fault status information. It is supplemented by an audible alarm that signals UPS startup, power failure, low battery, overload,
UPS fault and remote shutdown conditions.
Emergency Power Off(EPO) Capability
The SU2200XLCD features an EPO interface port that supports emergency shutoff in large facilities(cable included).
USB/DB9 Ports, SNMP Capability and Included PowerAlert Software
The SU2200XLCD features an HID-enabled USB port and a DB9 port(cables included). Used with Tripp Lite’s included PowerAlert software, these
communication ports provide comprehensive network power monitoring and control. Capabilities include UPS and line power status messaging(on battery,
low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity), timed inverter shutoff after unattended shutdown, and UPS
output power control for delayed or immediate reboot of connected devices. The SU2200XLCD also accepts an optional network management card accessory,
such as Tripp Lite's SNMPWEBCARD network interface.
Peace of Mind
The SU2200XLCD comes with$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only) for connected equipment.
Specifications
OUTPUT
Output Volt Amp Capacity (VA)2200
Output kVA Capacity (kVA)2.2
Output Watt Capacity (Watts)1800
Output kW Capacity (kW)1.8
Output Capacity Details
Power Factor0.82
Crest Factor3:1
ON LINE MODE: Maximum output capacity rating is reduced to 1620W (115V), 1530W (110V) and 1440W (100V);
FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation /
conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts) OVERLOAD
CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30
seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency
are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)
Nominal Output Voltage(s)
Supported
Nominal Voltage Details120V default
Frequency Compatibility50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output
matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds
+/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz.
FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency
when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz.
BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.
Nominal Input Voltage Description120V factory default
UPS Input Connection Type5-20P
Input Circuit Breakers30A
UPS Input Cord Length (ft.)10
UPS Input Cord Length (m)3.0
Recommended Electrical Service20A 120V
Input PhaseSingle-Phase
BATTERY
Full Load Runtime (min.)4.5 min. (1800w)
Half Load Runtime (min.)13 min. (900w)
Expandable Battery RuntimeExtended runtime supported via optional external battery packs
External Battery Pack Compatibility
Expandable Runtime Description
DC System Voltage (VDC)48
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery AccessBattery access door
Battery Replacement DescriptionHot-swappable, user replaceable batteries
Expandable RuntimeYes
VOLTAGE REGULATION
Voltage Regulation DescriptionOnline, double-conversion power conditioning
Overvoltage Correction2% output voltage regulation during overvoltages to 150
Undervoltage Correction2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
BP48V24-2U
External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual
for details
Less than 3 hours from 10% to 90%
RBC48-SUTWR
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating
data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
(limit 1);
BP48V60RT-3U
(multi-pack compatible);
BP48V27-2US
(multi-pack compatible)
Switches2 switches control off/on power status and alarm-cancel/self-test operation