Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU10000RT3U2TF
SmartOnline Expandable Rack/Tower UPS System - Online, double-conversion protection for mission-critical
applications
Highlights
10,000VA / 10kVA online 10U rack / tower UPS with expandable runtime (3U
Power Module + 3U Battery Pack + QTY 2 -2u stepdown transformers)
Zero transfer time, on-line, double-conversion and economy-mode operation
supported
Manual Bypass Switch and detachable PDU enables hot-swap UPS
replacement without powering off connected loads
Maintains 208V and simultaneous 120V output
2% output voltage regulation over an input voltage range of 156 to 276
Enhanced serial communications ports, SNMP/Web Card Slot and EPO
interfaces
$250,000 Ultimate LIfetime Insurance (USA & Canada only).
Description
10,000 VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 10 rack spaces
(3U power module, 3U battery pack and two 2U step-down transformers). Maximum installed rack depth of 32.5 in. Expandable battery runtime with
optional external battery packs. Full-time sine wave 208V and 120V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts
output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 156V and
overvoltages to 276V. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Standard 3-wire 208V
hardwire input connection; NEMA L6-30R, L6-20R and 5-15/20R output receptacles. Detachable input-output PDU module with manual bypass
switch enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero
transfer time between AC and battery operation. Network management interfaces support communications via RS-232, contact-closure port and
optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network
interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs offer
at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power
status. LED/LCD display panel easily rotates for better viewing in rackmount or tower configurations. LCD panel with scroll buttons offers detailed
diagnostic test information at startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and
battery charge level. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included;
2POSTRMKITWM two post rackmount hardware accessories available. Field-replaceable, hot-swappable power module and external battery 2-year
warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
Applications
Ideal for protection of sensitive electronics in any application calling for upright tower or 19-in. rackmount UPS protection. Common
applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems
Package Includes