The SMART1050 SmartPro 120V 1.05kVA 705W Line-Interactive UPS provides battery backup and AC power protection against blackouts, brownouts, power
surges and line noise that can damage electronics or destroy data. Ideal for backing up data centers, VoIP systems, points of sale and network closets, the
SMART1050 switches to 1.05kVA/705W battery mode in milliseconds to keep your connected equipment running long enough to save files and shut down
safely with no data loss.
Featuring six NEMA 5-15R outlets and a six-foot power cord with 120V NEMA 5-15P input, the SMART1050 has an internal battery that provides 23 minutes of
support at half load and eight minutes at full load. Front-panel LEDs indicate line power, battery power, overload, voltage regulation and battery status. An
alarm sounds to indicate power failure or a low battery.
Automatic voltage regulation (AVR) maintains 120V nominal output over an input range of 75V to 147V without using battery power. EMI/RFI noise filtering
improves your equipment’s performance and prevents damage. A 480-joule surge suppression rating protects your equipment from harmful power surges.
With Tripp Lite’s included PowerAlert software, the SMART1050 enables safe unattended system shutdown and file saves in case of a prolonged power failure.
Features
Protects Mission-Critical Equipment
Provides fully regulated AC output for servers, network storage devices and telecom hardware
Audible alarm signals loss of utility power or low battery
6 NEMA 5-15R outlets
6 ft. power cord with 120V NEMA 5-15P input
480-joule surge suppression rating
Reliable Battery Backup
Supports half load up to 23 min. and full load up to 8 min.
Internal batteries designed for hot-swap field replacement
96% line-power efficiency rating saves money in energy costs
Cold-start capability enables turn-on in battery mode during blackouts
Automatic Voltage Regulation(AVR)
Maintains 120V nominal output over input range of 75V–147V without using battery power
EMI/RFI Line Noise Filtering
Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s performance
LED Indicators
Front-panel LEDs signal indicate line power, battery power, overload, voltage regulation and battery status
USB Communication Port
USB port combines with included PowerAlert software to enable safe unattended system shutdown and file saves in case of a prolonged power failure
Supports messaging of UPS and line power status, including voltage and battery capacity
Small-Footprint Tower Housing
Uses less than 53 sq. in. of floor or desktop space
Mounts on wall with optional UPSWM accessory
Specifications
OUTPUT
Output Volt Amp Capacity (VA)1050
Output kVA Capacity (kVA)1.05
Output Watt Capacity (Watts)705
Nominal Output Voltage(s)
Supported
Nominal Voltage Details120v nominal output in battery mode
Frequency Compatibility60 Hz
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles(6) 5-15R
Output AC Waveform (AC Mode)Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
INPUT
Rated input current (Maximum Load)6.7A
Nominal Input Voltage(s) Supported120V AC
110V; 115V; 120V
-18%, +8%
+/- 5%
UPS Input Connection Type5-15P; Right-Angled
Input Circuit Breakers12A
UPS Input Cord Length (ft.)6
UPS Input Cord Length (m)1.8
Recommended Electrical Service15A 120V
Input Cord Length (ft.)6
Input Cord Length (m)1.8
Input PhaseSingle-Phase
BATTERY
Full Load Runtime (min.)8 min. (705w)
Half Load Runtime (min.)23 min. (355w)
DC System Voltage (VDC)18
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery AccessBattery access door
Battery Replacement DescriptionHot-swappable, user replaceable batteries
Expandable RuntimeNo
VOLTAGE REGULATION
Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Overvoltage CorrectionInput voltages between 128 and 147 are reduced by 12%
Undervoltage CorrectionInput voltages between 93 and 107 are boosted by 14%
Severe Undervoltage CorrectionInput voltages between 75 and 92 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
Audible AlarmAudible alarm indicates power-failure and low-battery conditions
Less than 4 hours from 10% to 90% (typical, full load discharge)
(quantity 3)
RBC52
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating480
UPS AC Suppression Response
Time
Instantaneous
EMI / RFI AC Noise SuppressionYes
AC Suppression Joule Rating480
AC Suppression Response TimeInstantaneous
PHYSICAL
Installation Form Factors Supported
with Optional Accessories
Primary Form FactorTower
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
UPS Power Module Weight (lbs.)29
UPS Power Module Weight (kg)13.2
UPS Shipping Dimensions (hwd / in.) 15 x 10.8 x 11.2
UPS Shipping Dimensions (hwd /
cm)
Shipping Weight (lbs.)31
Shipping Weight (kg)14.1
UPS Housing MaterialPolycarbonate
ENVIRONMENTAL
Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Wallmount(
11.8 x 7.2 x 7.2
29.8 x 18.4 x 18.4
38.1 x 27.3 x 28.6
UPSWM
- tower mounting kit)
Relative Humidity0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)99.9
Battery Mode BTU / Hr. (Full Load)326.9
AC Mode Efficiency Rating (100%
Load)
COMMUNICATIONS
Communications InterfaceUSB
Network Monitoring Port DescriptionSupports detailed monitoring of UPS and site power conditions
PowerAlert SoftwareIncluded
Communications CableUSB cable included
WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time2-4 milliseconds
96%
Low Voltage Transfer to Battery
Power (Setpoint)
75
High Voltage Transfer to Battery
Power (Setpoint)
SPECIAL FEATURES
Cold Start (Startup in Battery Mode
During a Power Failure)
High Availability UPS FeaturesHot swappable batteries
Green Energy-Saving FeaturesGreater than 95% efficiency - GREEN UPS
CERTIFICATIONS
UPS CertificationsTested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
WARRANTY
Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration. Note:
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
147
Cold-start operation supported
$250,000
Ultimate Lifetime Insurance
Registration is required
for 3-year warranty.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.