Model Number: PDU3VN10G60
3-Phase Monitored PDU,12.6 kW, 36 208V outlets (30 C13, 6 C19), 10-ft. IEC-309 Blue 60A input, 0U vertical
mount
Highlights
Monitored 12.6kW 3 Phase 208V PDU; 70 in. / 178cm 0U vertical rackmount
Reports voltage, frequency and load per-phase via built in ethernet interface
Visual current meter; Toolless button-mount installation
IEC-309 Blue 60A (3P+E) 208V 3 phase input; 10 ft. / 3m line cord
30 C13 & 6 C19 single phase outlets; Included cord retention brackets
Temperature, humidity and contact closure monitoring options
Description
Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in
network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or
SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely
to warn of potential overloads before critical IT mains breakers trip.
Applications
Ideal for 3 phase network configurations in datacenters and heavily configured equipment racks
Package Includes
Monitored rackmount PDU with pre-installed mounting buttons
Cord retention brackets
Spare installation buttons (2 9mm / 4 6mm)
Rack mounting brackets
Owner's manual
Features
12.6kW 3 phase 208V Monitored Power Distribution Unit / PDU with built-in web/network interface
Attached IEC-309 Blue 60A (3P+E) 208V 3 phase input plug with 10 ft. / 3m cord
0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks
36 total 208V outlets (30 C13, 6 C19) arranged in three breakered single phase output load banks
Lighted display with scroll-button reports power consumption in amps for all 3 loading banks, IP-address self-identification and 180 degree
display rotation for overhead or raised floor power feeds
Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading per-phase via network or secure web browser interface with
options for user specified alarm and notification thresholds
Supports in-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to
4 optional SRSWITCH door sensors
DHCP/Manual configuration support
10/100 Mbps auto-sensing allows optimal communication with 10/100 Base-T networks
Real-time clock backup maintains the time of day and date even if the PDU is unpowered
Tiered access privileges allow an administrator and a guest to login via web browser for monitoring