Trendnet TL2-E284 User Manual

Page 1
Quick Installation Guide
TL2-E284
1.01
Page 2
Table of Contents
English 1
1. Before You Start
2. Hardware Installation 2
3. LEDs 3
4. Configure the Switch 5
Troubleshooting 9
1
Page 3
1. Before You Start
Package Contents
TL2-E284
Ÿ ŸMulti-Language Quick Installation Guide ŸCD-ROM (User's Guide) ŸRS-232 cable (3 m / 9.8 ft.) ŸPower Cord (1.8 m / 5.9 ft.) ŸRack Mount Kit
Installation Requirements
Web Browser: Internet Explorer (6.0 or higher)
Ÿ ŸA computer with a network adapter properly installed ŸCAT-5e or CAT-6 Network Cable ŸThe surface must support at least 2 Kg (4.4 lbs) for the Switch ŸThe power outlet should be within 1.8 meters (5.9 feet) of the Switch ŸMake sure that there is proper heat dissipation from and adequate ventilation around the
Switch
ŸDo not place heavy objects on the Switch
Optional Equipment
EIA standard 19” rack
Ÿ ŸMini-GBIC module (e.g. TEG-MGBSX, TEG-MGBS10, TEG-MGBS40, TEG-MGBS80,
TEG-MGBS10D35, TEG-MGBS40D35) for Mini-GBIC slots
1
Page 4
2. Hardware Installation
Note:
Note: The Mini-GBIC slots are shared with port 25 and 26 Gigabit Ethernet ports. When the Mini-GBIC slots are in use, port 25 and 26 Gigabit Ethernet ports are disabled.
1. Connect the Power Cord to the TL2-E284 and then to a power outlet.
2. Connect a Cat.5e or Cat.6 RJ-45 network cable from the computer to an available Ethernet port on the TL2-E284.
3. Verify that the following panel lights are on:
PWR(Power), SYS(System) and 10M LINK/ ACT, 100M LINK/ACT, 10/100M LINK/ACT or 1000 LINK/ACT.
2
Page 5
3. LEDs
PWR (Power)
SYS (System)
1000M LINK/ACT
10/100M LINK/ACT
10/100M LINK/ACT
10M LINK/ACT
3
Page 6
Device Status LED
PWR (Power)
SYS (System)
Ethernet LED (RJ-45)
100M Link/ACT
10M Link/ACT
Combo Gigabit Ethernet (RJ-45) / Mini-GBIC LED
1000M Link/ACT
10/100M Link/ACT
Color
Green
N/A
Green
N/A
Color
Green
Amber
Color
Green
Amber
Sequence
Solid
Off
Solid
Off
Sequence
Solid
Blinking
Off
Solid
Blinking
Off
Sequence
Solid
Blinking
Off
Solid
Blinking
Off
Definition
Device powered On
Device powered Off
Device is ready
Device is not ready
Definition
100/200Mbps (Half/Full Duplex) Connected (per port)
100/200Mbps (Half/Full Duplex) Data Transmitting/Receiving (per port)
10/20Mbps (Half/Full) or no connection to the port
10/20Mbps (Half/Full Duplex) Connected (per port)
10/20Mbps (Half/Full Duplex)Data Transmitting/Receiving (per port)
100/200Mbps (Half/Full), or no connection to the port
Definition
2000Mbps (Full Duplex) Connected (per port)
2000Mbps (Full Duplex) Data Transmitting / Receiving (per port)
100/200Mbps (Half/Full), 10/20Mbps (Half/Full), or no connection to the port
10/20Mbps (Half/Full Duplex) or 100/200Mbps (Half/Full Duplex) Connected (per port)
10/20Mbps (Half/Full Duplex) or 100/200Mbps (Half/Full Duplex) Data Transmitting/Receiving (per port)
2000Mbps (Full), or no connection to the port
4
Page 7
4. Configure the Switch
Note:
1. Before the Switch can be configured, a Static IP address must be assigned to your computer's network adapter in the subnet of 192.168.10.x. Since the Switch's default IP address is
192.168.10.200, make sure no other network devices are assigned an IP address of
192.168.10.200. (Refer to Troubleshooting section on how to configure TCP/IP settings on your PC.)
2. There are three methods of configuring the TL2-E284: Web Browser, Console Port and Telnet.
1. Using Web Browser
1. Open your web browser, type
http://192.168.10.200 in the Address bar, and then press Enter.
2. Enter the User name and Password, and then
click Login. By default: User Name: admin Password: admin
3. Select the desired options for configuring the
switch.
5
Page 8
2. Using the Console Port
Note: A terminal program such as HyperTerminal is required to configure the switch via the Console Port. The instructions shown below demonstrates how to configure the Switch on a Windows PC using HyperTerminal.
1. Connect the RS-232 cable from a serial port on
your PC to the console port on the switch.
2. Go to Start Ž Programs Ž Accessories Ž
Communications Ž HyperTerminal
3. Enter a name, choose an icon and then click
OK.
4. Select the correct COM port
(e.g. COM1, COM2) and then click OK.
6
Page 9
5. Enter the following, click Apply and then
click OK. Bits per second: 115200 Data bits: 8 Parity: None Stop bits: 1 Flow control: None
6. Press the Enter Key.
7. Enter the User Name for login. Then press the
Enter. Then Enter the Password and then
press Enter.
By default
login: admin Password: admin
If you do not see the login prompt, please
power cycle the switch by unplugging the
power cord, wait 15 seconds and then plug it
back in.
3. Using Telnet
The Telnet function may or may not be included with your computer's operating system. For instructions on how to enable Telnet in Windows 7/Vista, please refer to the Troubleshooting section.
1. Click the Windows / Start icon on the bottom
left hand corner and click All Programs.
7
Page 10
2. Click Accessories and then click Command
Prompt.
3. Type in telnet 192.168.10.200. Then press the
Enter key.
4. Enter the User Name for login. Then press the
Enter. Then Enter the Password and then
press Enter. By default
login : admin
Password: admin
If you do not see the login prompt, please
power cycle the switch by unplugging the
power cord, wait 15 seconds and then plug it
back in.
Configuration is now complete
For detailed information regarding the TL2-E284 configuration and advanced settings, please refer to User's Guide included on the Utility CD-ROM, or TRENDnet's website at http://www.trendnet.com.
Register Your Product
To ensure the highest level of customer service and support, please take a moment to register your product Online at: www.trendnet.com/register
Thank you for choosing TRENDnet
8
Page 11
Troubleshooting
1. How do I configure TCP/IP settings on my computer?
Windows 7
1. Go into the Control Panel, click Network and Internet,
click Network and Sharing Center, click Change Adapter Settings and then right-click the Local Area Connection icon and then click Properties.
2. Click Internet Protocol Version 4(TCP/IPv4) and then click Properties. Then click on Use the following IP address, and make sure you assign your network
adapter an IP address in the subnet of 192.168.10.x.
Windows Vista
1. Go into the Control Panel, click Network and Internet, click Network and Sharing Center, click Manage Network Connections and then right-click the Local Area Connection icon and then click Properties.
2. Click Internet Protocol Version 4(TCP/IPv4) and then click Properties. Then click on Use the following IP address, and make sure you assign your network
adapter an IP address in the subnet of 192.168.10.x.
Windows XP / 2000
1. Go into the Control Panel, double-click the Network Connections icon and then right-click the Local Area Connection icon and then click Properties.
2. Click Internet Protocol Version (TCP/IP) and then click Properties. Then click on Use the following IP address, and make sure you assign your network
adapter an IP address in the subnet of 192.168.10.x.
9
Page 12
2. I typed http://192.168.10.200 in my Internet Browser's Address Bar, but an error message says “The page cannot be displayed.” How can I get into the TL2-E284's web configuration page?
1. Check your hardware settings again by following the instructions in section 2.
2. Make sure the PWR(Power), SYS(System) and Link/ACT lights are lit.
3. Make sure your network adapter’s TCP/IP settings are configured properly (see Q1).
4. Since the Switch's default IP address is 192.168.10.200, make sure that no other network devices are assigned an IP address of 192.168.10.200.
3. If my switch's IP is different than the network’s subnet, what should I do?
You should still configure the Switch first. After all the settings are applied, go to the Switch's configuration page, click on Administrator, click IP & Management Mode and change the IP address of the Switch to match your network's IP.
4. What are the default port settings for configuring the Switch through the console port using HyperTerminal?
Bits per Second: 115200; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None.
5. I changed the IP address of the switch, but I forgot it. How do I reset my TL2-E284?
Follow the instructions below:
1. Take a pin or paper clip and press the reset button on the front of the switch
2. Wait 15 seconds then let go. The default IP address of the switch is 192.168.10.200. The default user name and password is admin.
6. How do I enable Telnet on my Windows 7/Vista computer?
Follow the instructions below: Windows 7
1. Go to Control panel and click Programs.
2. Click Turn Windows features on or off.
3. Check the box next to Telnet client and then click OK.
4. Please wait while Windows enables Telnet.
Windows Vista
1. Go to Control Panel and click on Classic View.
2. Click on Programs and Features.
3. Click Turn Windows features on or off.
4. Check the box next to Telnet Client and then click OK.
5. Please wait while Windows enables Telnet.
If you still encounter problems or have any questions regarding the TL2-E284 please contact TRENDnet's Technical Support Department.
10
Page 13
11
Page 14
Page 15
Copyright ©2010, All Rights Reserved. TRENDnet.
Loading...