The widest workload of any multi product
calibrator - over 18 types of instruments with
power to drive older analogue instruments and
the accuracy to calibrate modern digital
instruments
Ideal for both laboratory and on-site use.
Modern technology provides a fast warm up
time and extremely portable design.
Automate calibration with ProCal - the worlds
easiest to use multi discipline calibration
software for maximum calibration throughput
The most cost effective calibration system on
the market - 3 models to suit budget & accuracy
requirements
The wide range of options allows the
calibrator to be tailored to meet your needs expandable for the future
Intuitive front panel design with large LCD
display and ergonomic keyboard for ease of use
Full output protection including system prevents output being switched on when voltage
detected on terminals
2
Guaranteed reliability with 3 year warranty
as standard
THE FLEXIBLE SOLUTION FOR YOUR CALIBRATION WORKLOAD
Comprehensive Instrument Calibration
Ü
Meeting Workload Requirements
The 3000 Series calibration system has been designed to help you &
your business, allowing a wide range of calibration work to be performed
quickly, accurately & economically. Modern calibration is a competitive
market, and cost effective equipment and software are key
considerations.
Meeting the needs of today's quality systems including ISO9000 /
ISO17025 require calibration traceable to national standards of a wide
range of instrumentation. The 3000 Series calibration system provides
the ideal platform to cover these calibration requirements, whether in the
laboratory or on site. Every Transmille calibrator and adapter is supplied
with UKAS calibration traceable to National standards, and are ready for
use out of the box.
Offering the widest workload coverage of any calibration system
presently available, the 3000 series is a true class leading solution. The
unique concept of external calibration adapters combined with built-in
measurement capability dramatically extends the range of instruments
that can be cost effectively calibrated.
Automated Calibration & Management Software
ProCal is the genuinely easy to use calibration software which
complements the 3000 Series calibration system to provide a complete
laboratory solution. Maximum calibration throughput is achieved with
multi discipline support. ProCal-Track adds laboratory management
control with dynamic job tracking from goods inwards to despatch streamlines laboratory operation.
25PPM MULTI PRODUCT CALIBRATOR
Ü
Ü
ÜÜ
MID RANGE MODELLABORATORY REFERENCE
CALIBRATION ADAPTERS
CALIBRATION SOFTWARE
Ü
ÜÜ
50PPM MULTI PRODUCT CALIBRATOR
ENTRY LEVEL MODEL
TRANSCONDUCTANCE AMP
MULTI FUNCTION WORKSTATION
I-GUARD
8PPM MULTI PRODUCT CALIBRATOR
Ü
AC/DC KILOVOLT AMPLIFIER
2/10/50 TURN CLAMP COIL
Ü
CALIBRATES...
UP TO 7½ DIGIT MULTIMETERS :: 3010
Ü
UP TO 5½ DIGIT MULTIMETERS :: 3041
Ü
UP TO 4½ DIGIT MULTIMETERS :: 3050
Ü
DIGITAL OSCILLOSCOPES TO 600MHz
Ü
CLAMP METERS
Ü
WATT / POWER METERS
Ü
RLC METERS / AC BRIDGES
Ü
POWER SUPPLIES
Ü
INSULATION TESTERS
Ü
PROCESS CONTROL CALIBRATORS
Ü
HIGH RESISTANCE MEASUREMENT
Ü
ELECTROMETERS
Ü
CURRENT SHUNTS
Ü
DATA LOGGERS
Ü
PRESSURE GAUGES
Ü
HV PROBES
Ü
TORQUE SCREWDRIVERS
Ü
FREQUENCY COUNTER/TIMERS
Ü
CHART RECORDERS
Ü
AND MORE...
Ü
FOR RCD • LOOP • PAT TESTERS
See the Transmille 3200 Electrical
Test Equipment Calibrator Brochure.
3
3000SERIES
3000
THE FLEXIBLE SOLUTION FOR YOUR CALIBRATION WORKLOAD
8
PPM ACCURACY MODEL 3010
25
PPM ACCURACY MODEL 3041
PPM ACCURACY MODEL 3050
50
AC/DC VOLTAGE TO 1025V
V
A
AC/DC CURRENT TO 30A
2&4 WIRE RESISTANCE TO 1GW
W
F
H
Hz
RTD
PRT
RS
232
GPIB
USB
W
O
Ü
PASSIVE & SIMULATED MODES
CAPACITANCE TO 10mF
PASSIVE & SIMULATED MODES
INDUCTANCE T O 10H
FREQUENCY TO 10MHz
RTD/PRT SIMULATION
RS232 INTERFACE BUILT IN
GPIB / USB OPTIONS
AC/DC POWER CALIBRATION
WITH POWER HARMONICS
OSCILLOSCOPE CALIBRATION
250MHz • 350MHz • 600MHz OPTIONS
BUILT IN ADAPTER INTERFACE
INTEGRATED HIGH ACCURACY MEASUREMENT FUNCTION
THERMOCOUPLE SIMULATION ADAPTER
POWER SUPPLY CALIBRATION ADAPTER
HUMIDITY/TEMPERATURE SENSOR ADAPTER
OSCILLOSCOPE CALIBRATION TEST HEAD ADAPTER
PLUS...HIGH RESISTANCE / pA MEASUREMENT ADAPTER
PA SOURCE ADAPTER
OPTICAL TACHOMETER CALIBRATION ADAPTER
PRESSURE CALIBRATION ADAPTER
TORQUE CALIBRATION ADAPTER
Clear presentation of calibrator outputs & status on a
large graphic LCD display for safe & easy operation.
ADVANCED TECHNOLOGY
The 3000 series calibrators use the latest technology from the
temperature stabilised reference to the sub ppm linearity D/A.
DDS (Direct Digital Synthesis)
jitter free wideband AC waveforms. Custom waveforms for use in
harmonics calibration are available with the 3041/3010 power options.
An ultra-linear VMOS power amplifer
capability with continuous output available up to 20A. A power efficient
design with two-stage cooling has resulted in reduced internal thermal
EMFs for superior short term stability whilst reducing fan noise for a more
comfortable working environment.
intelligent output protection safeguards the calibrator by testing
I-GUARD
the output sockets for voltages applied accidentally when switching from
standby to output on - protects your investment from accidental misuse.
4
technology is used for generating stable,
provides a ground breaking 30A
Separate outputs for
Voltage, Low Current
and High Current
minimise lead
changing when
connecting. Dedicated
BNC outputs for
oscilloscope
(Amplitude / Timebase
/ Freq. Sweep) and
Frequency.
Soft keys
provide direct access to the
menu commands, unlocking the
potential of the 3000 Series
calibrators.
Large output on and standby buttons
and useful range up/down buttons
also add to the ease of use.
RA
PORTABLE
The ultra portable 3000 Series calibrators
begin a new era in true on-site calibration.
Using the soft, over the shoulder tailored
travel case, your calibration system can be
taken with you to the calibration work,
whether it is in an aircraft hanger, on board
a ship or oil rig.
A fast warm up time ensures the 3000
Series will be ready to work wherever you
are. Connect to your laptop for a complete
automated calibration system.
,
Ergonomic calculator style keypad makes it
easy to enter values. Intuitive function keys
and key layout makes using the function
control section second nature.
Adapter interface for power,
control and measurement for the
range of calibration adapters.
S
SOURCE
MEASURE
ÜÜÜ
The 3000 Series generates all the outputs required for
multimeter calibration, plus options for :
Oscilloscope Calibration
base, fast rise and bandwidth up to 600MHz. A key
feature is the ability to support the growing number of
oscilloscopes with 50V/Div (300V Pk-Pk) ranges.
AC/DC Power Calibration
voltage to 1025V and current to 30A outputs to simulate
power up to 30.6kW (1.5MW using the 50 turn coil).
Phase angle control up to 359.9° is available.
Harmonics Calibration
3010 includes five preset waveforms and support for
custom defined harmonics upload using a PC.
Built-in source and measurement
M
capabilities incorporating a high
linearity A/D converter.
COMPLETE WORKLOAD CAPABILITY
including amplitude, time
uses simultaneous generated
option available for 3041 &
Integrated Calibration
Workstation
for clamp meter, insulation
testers, process control
calibrator, temperature meter &
optical tachometer calibration
RCL Meters
unique to the Transmille 3000 Series.
The passive inductance, resistance & capacitance in the 3000
Series are suitable for measurement using any technique,
including. For total flexibility simulated resistance
and capacitance options are also available.
Frequency Meter
accuracy to 1ppm
Using the external calibration adapters,
Process Control Calibrators, Electrometers, Insulation
Testers, Pressure Gauges and Transmitters, even Torque
Screwdrivers
can be calibrated using the inductance option,
AC Bridges
calibration up to 10MHz is supported with
Power Supplies,
can be calibrated quickly and efficiently.
5
3000
SERIES OSCILLOSCOPE CALIBRATION OPTION
SCP250 / SCP350 / SCP600
AMPLITUDE
Easily selected using the softkeys, the calibrator produces either a precision 1kHz
square wave or a DC level covering the range from 2mV/Div to 50V/Div in a 1,2,5
sequence. Deviation up to 10% in 0.01% steps can be applied using the digital
potentiometer. The calibrator's wide range output, giving up to 300V pk-pk, can be
used to directly calibrate the ever increasing number of oscilloscopes with amplitude
ranges up to 50V/Div placing it in a class leading position.
TIMEBASE
The timebase function of the oscilloscope option provides outputs from 2ns/Div to
5s/Div. Deviation up to 10% in 0.01% steps can be applied using the digital control.
To use, simply align the time marker with the graticule display and read the
deviation from the % display on the calibrator. The comb waveform used below
100ns is ideal for triggering on both analogue and digital oscilloscopes alike. For
faster timebase calibration, a sine wave is produced which makes viewing on
bandwidth limited oscilloscopes easier. The timebase output can be used either
directly or into a 50 Ohm input.
SPECIFICATIONS
Voltage Amplitude
Range
Sequence
Frequency
Accuracy
Time Markers
Range
Sequence
Waveshape
Accuracy
Fast Rise*
* 3041 / 3010 only
Leveled Sweep
Range (SCP250)
Range (SCP350)
Range (SCP600)
Leveled Sweep
Reference Level
Accuracy
50kHz Reference
Frequency Accuracy
Level Accuracy
See extended specifications for full details
6
2mV/Div to 50V/Div
1 • 2 • 5
1kHz
0.01% ± 5uV
2ns to 5s
1 • 2 • 5
Comb < 100ns
Sine > 100ns
5ppm
1ns typical
5MHz to 250MHz
5MHz to 350MHz
5MHz to 600MHz
600mV into 50Ohms
50kHz
0.5dbm
30ppm
0.5%
Three options are available for the 3000 Series calibrators which are suitable for
calibration of both analogue and digital storage oscilloscopes.
250MHz (SCP250) : 3050
350MHz (SCP350) : 3041 / 3010
600MHz (SCP600) : 3041 / 3010
All options provide the calibration waveforms required for amplitude,
timebase and bandwidth including gain and linearity of the horizontal and
vertical deflection circuits. To minimise lead changing, the oscilloscope
outputs are output from a single BNC connector - for automated calibration
an optional 4 channel test head adapter is available.
Amplitude to 50V/Div (300V Pk-Pk) - 1,2,5 sequence
Timebase to 2ns
Separate trigger output
All calibration signals from a single BNC
FAST RISE
A fast rise output is available with a rising edge
time of typically 1ns for evaluating overshoot,
undershoot and ringing of oscilloscope
attenuation and amplifier circuits.
LEVELED SWEEP
The leveled sweep output of the oscilloscope option
provides a continuously variable sine wave from
5MHz to 620MHz. A 50kHz reference level
waveform is also available to allow the oscilloscope
controls to be set to give a 6 graticule height display.
OSCILLOSCOPE CALIBRATION TEST HEAD
SOURCE
EA017
For automating oscilloscope calibration a 4 channel switching test head is
available. Connect to the 3000 Series adapter interface and select channel
required. For accurate calibration of 50Ohm input oscilloscopes up to 1V/Div
a low impedance buffered amplitude output can be selected.
SPECIFICATIONS
Channels
Input
Output
Output Impedance
Direct
Buffered
See extended specifications for full details
1
4
As Input
Typically 0.2
3000
SERIES POWER CALIBRATION OPTION
PWR50 / PWRSINE / PWRDDS
AFFORDABLE AC/DC POWER CALIBRATION
Three options provide cost effective calibration of power (Watts) and VA ranges
on power meters, power/harmonics analysers & clamp meters. The power option
for the 3000 series calibrators allows both voltage current output to be generated
simultaneously (phantom load) with an adjustable phase
angle relationship.
3050 : Sine power option (PWR50)
3041/3010 : 2 options
PWRSINE : Sine & DC power
PWRDDS : 5 waveforms+custom & DC
Up to 1.5MW (using 50 Turn Clamp Coil)
0° to 359.9° adjustable phase relationship
Any voltage up to 1025 Volts can be set using the normal output ranges and
specification of the calibrator. Currents up to 30Amps are available from the output of
the calibrator without the need for an external amplifier.
The power function is extremely easy to use - select 'Power' from the soft key menu,
connect the power meter to both the voltage and current output terminals and enter
the voltage, current and frequency. Phase angle can be adjusted using the softkeys
with a resolution of 0.1
The 3000 series calibrator dynamically controls the phase angle between the current
and voltage waveforms eliminating errors caused by capacitive or inductive loading
experienced when using clamp coils.
TCXO
OSCILLATOR
Extended Power Range Using The 2 / 10 / 50 Clamp Coil
Combined with the optional clamp coil adapter the power calibration
option allows a current of 1500Amps to be simulated, and power
to1.5Megawatt (1500Amps x 1000Volts).
Power Harmonics Analyser Calibration Using
Programmable Waveforms (Option PWRDDS)
Option PWRDDS for the 3041 and 3010 calibrators allows generation of
waveforms with harmonic content for calibrating power meters with
power harmonics functions. This includes a set of five fixed waveforms,
plus the capability to upload user defined waveforms from a PC
allowing waveforms with custom harmonic content to be generated.
kWatt hour meter & Energy Calibration.
°. Power output is calculated & displayed in kW.
ACV
WAVEFORM
PHASE
CONTROL
PHASE
CONTROL
PHASE ANGLE
CONTROL
GENERATION
FREQUENCY
CONTROL
DIGITAL
MICROPROCESSOR
CONTROL
FREQUENCY
CONTROL
ACI
WAVEFORM
GENERATION
Using the 3000 Series VFP the Voltage,
current, frequency, phase angle, time
and the number of coil turns can all
easily be set, click the energy button and
the power is turned on for a set period
making calibration of kWatt/hours and
energy meters easy.
VOLTAGE
O/P
PHASE
COMPARATOR
CURRENT
O/P
SPECIFICATIONS
DC Power (3041/3010)
Voltage Range
Current Range
Resolution 300mA to 2A
2A to 30A
Accuracy 300mA to 2A
2A to 30A
AC Power
Voltage Range
Frequency Range
Resolution
300mA to 2A
2A to 30A
Accuracy : 3041/3010
300mA to 2A
2A to 30A
Accuracy : 3050
300mA to 2A
2A to 20A
Phase Angle Resolution
Phase Accuracy
See extended specifications for full details
CURRENT
PHASE
VOLTS
0 to 1025V
300mA to 30A
200uA
2mA
0.05% ± 0.35mW/Volt
0.04% ± 3.5mW/Volt
0 to 1025V
40Hz to 1kHz
200uA
2mA
0.05% ± 0.35mW/Volt
0.05% ± 3.5mW/Volt
0.1% ± 0.5mW/Volt
0.1% ± 5mW/Volt
0.1°