FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:
1. Is the P(o)W(e)R LED on the media converter illuminated?
NO
• Is the power cord properly installed in the media converter and in
the grounded AC outlet?
• Does the grounded AC outlet provide power?
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 2.
2. Does the 10/100TX STAT(us) LED blink ONCE and then go off?
YES
• Check twisted pair cables for proper connection.
• Contact Technical Support: (800) 260-1312.
NO
• Proceed to step 3.
3. Does the 10/100FX STAT(us) LED blink FIVE TIMES and then go
off?
YES
• 10Mb/s: Receive Pair has wrong polarity.
• 100Mb/s: Proceed to step 4.
NO
• Proceed to step 4.
4. Does the 10/100SX STAT(us) LED blink ONCE and then go off?
YES
• Check fiber cables for proper connection.
• Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
• Contact Technical Support: (800) 260-1312.
NO
• Proceed to step 5.
5. Is the 100 LED blinking?
NO
• The media converter has selected 10 Mb/s operation. If this is NOT
the correct speed, disconnect and reconnect the 10/100BASE-TX
cable to restart the initialization process. If the fault is not corrected,
proceed to step 6.
YES - SLOWLY
• The media converter is selecting between 10 Mb/s and 100 Mb/s
speed OR one or both of the links is down. IF PERSISTENT,
disconnect and reconnect either cable to restart the initialization
process. If the fault is not corrected, proceed to step 6.
INSTALLATION
Install Cable
COPPER
NOTE: AutoCross™ allows the use of either straight-through or crossover
configuration cables.
1. Locate or build 10BASE-T-compliant or 100BASE-TX-compliant
cables with male RJ-45 connectors installed at both ends.
2. Connect RJ-45 connector at one end of cable to media converter
RJ-45 port connector.
3. Connect RJ-45 connector at other end of cable to 10BASE-Tcompliant or 100BASE-TX-compliant device RJ-45 port
connector.
FIBER
1. Locate or build 10/100BASE-SX-compliant fiber cable with male
two-stranded TX to RX connectors installed at both ends.
2. Connect male TX and RX cable connectors at one end of cable to
TX and RX female connectors, respectively, on media converter.
3. Connect male TX and RX cable connectors at other end of cable to
10/100BASE-SX-compliant device RX and TX connectors,
respectively.
Connect to Power
1. At media converter side opposite cable connections, locate male
power receptacle.
2. Plug female end of media converter power cord into media
converter power receptacle.
3. Plug male end of power cord into correct voltage, properly
grounded, AC power source.
4. Verify that media converter is powered by observing illuminated
power and status LED(s).