Transition Networks E-TBT-HB-0802 User Manual

(E-TBT-HB-0802)
7364.A
For assistance in installing, using, or maintaining the TRANSITION Networks LANMaster T8 10BaseT Ethernet™ Hub, contact TRANSITION Networks Technical Support
(800) 260-1312
or contact your local distributor.
LANMaster T8
8-Port Ethernet Hub w/SIC Slot
LANMaster T8
Compliance Information
UL Listed
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own cost.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the Radio Interference Regulations of the Canadian Department of Communications.
Copyright Restrictions
© 1995 TRANSITION Networks Inc. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks Inc.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
8-Port Ethernet Hub w/SIC Slot
TN’s total liability in connection with the products and installation thereof to all persons and from all causes in the aggregate whether in contract, tort, or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage. However, in no event shall TN have any liability to a customer or any third party with respect to a product manufactured in accordance with customer’s specifications.
C. Return Procedure
Before TN item(s) can be returned, a Credit Return Authorization (CRA), Return Material Authorization (RMA), or Material Repair Authorization (MRA)number must be obtained from TRANSITION Networks (TN) or the distributor of origin.
Locate the serial number(s) of the item(s) to be returned. From the item serial number, TN or the distributor will verify the return status and provide the appropriate number to the End User. The three types of return numbers are listed below:
A Credit Return Authorization (CRA) number can only be requested from your distributor. This CRA number will only be issued to distributors for item(s) within 90 days from the original ship date. Under no circumstances will a CRA number be issued directly to the End User. The return item(s) must be shipped freight prepaid, by the End User or the Distributor to TN.
A Return Material Authorization (RMA) number can be requested from TN or your distributor. This RMA number is only issued for item(s) after 90 days from the original ship date but prior to the expiration of the warranty period. The return item(s) must be shipped freight prepaid, by the End User or Distributor, to the TN address below:
TRANSITION Networks Inc. 6475 City West Parkway Eden Prairie, MN 55344 USA
TRANSITION Networks will repair or replace the unit, at its discretion, and cover the cost of the return freight to the distributor or End User who was issued the RMA number.
A Material Repair Authorization (MRA) number can be requested from TN or your distributor. This MRA number is only issued for out-of-warranty item(s). The return item(s) must be shipped freight prepaid, by the End User, to the TN address above. The sender will be contacted by TN after the item(s) have been received, inspected, and a cost estimate of the repair has been determined. The repair charges may be billed, with approval, through your distributor or prepaid/C.O.D. basis through the End User. In either case, charges will include freight, both ways, and repair charges.
The return authorization number is only valid for 60 days from the date of issuance. Please list this number on the outside of the carton and/or packing list. Include a copy of the original invoice or packing slip to expedite processing.
D. Restocking Fee
All returns for credit must be received in the same condition as originally shipped. If TN determines that a returned product is damaged due to improper packaging or if the item is functional and returned because of customer error, inability to use, etc., TN reserves the right to charge a minimum 15% ($10.00 minimum per item) restocking fee, the payment of which is a condition precedent to the repair and/or return of the product.
20
LANMaster T8
Table of Contents
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . 1
The LANMaster T8 8-Port Ethernet Hub w/SIC Slot . . . . . . . .1
LANMaster T8 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Networking the LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . . . .2
Connectors, Indicators and Switches . . . . . . . . . . . . . . . . . . .3
2 SITE CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . 4
Ensuring Compliance with 5-Segment Rule . . . . . . . . . . . . . .5
Ensuring Correct 10BaseT Configuration . . . . . . . . . . . . . . . .6
3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unpacking the LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . . .7
Installing LANMaster T8 on Flat Surface . . . . . . . . . . . . . . . .8
Connecting 10BaseT Cable at LANMaster T8 Front . . . . . . . .9
Installing Slide In Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Connecting Cable to Slide In Cards . . . . . . . . . . . . . . . . . . .11
Twisted Pair Connector/10BaseT Connection . . . . . . . . . . . . .11
Female AUI Connector/10Base5 Connection . . . . . . . . . . . . .12
Male AUI Connector/PC Connection . . . . . . . . . . . . . . . . . . . .12
BNC Connector/10Base2 Connection . . . . . . . . . . . . . . . . . . .13
Fiber Optic Connector/Fiber Optic Connection . . . . . . . . . . . .13
Powering the LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . . .14
4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Monitoring Power LED . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Monitoring Port/Indicator LEDs . . . . . . . . . . . . . . . . . . . . . .15
5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 16
LANMaster T8 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . 17
CABLE SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
POLICY AND PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . 19
i
19
8-Port Ethernet Hub w/SIC Slot
Policy And Procedure
A. Limited Warranty
TRANSITION Networks (TN) warrants, for a period of two years (with the exclusion of five years for passive balun products) from the date of shipment to the original purchaser and at the original point of installation, that products of TN’s design will be free from defects in materials and workmanship and in conformity with TN’s specifications. TN’s sole warranty with respect to products manufactured or assembled by TN in accordance with a customer’s specifications is a two year warranty that such goods conform to such specifications. These warranties do not extend to goods that have been subject to alterations, misuse, accident, tampering, improper maintenance, improper installation or abuse.
THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TN, AND TO THE EXTENT PERMITTED BY LAW, TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES (EXCEPT TITLE), EXPRESSED OR IMPLIED, INCLUDING BUT LIMITED TO ANY WARRANTY OF DESCRIPTION, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN, ITS EMPLOYEES, AGENTS, OR REPRESENTATIVES.
B. Limitations and Exclusions
If customer believes any goods sold hereunder are defective pursuant to the warranty and within the warranty period set forth above, the customer must notify TN within such period. TN will promptly issue a return form for such goods. Upon receipt of the form, customer is to promptly return the allegedly defective goods at customer’s expense and shipped prepaid to your distributor or TN (refer to the next subsection C, Return Procedure).
No goods will be accepted for return unless a prior return form is obtained from TN, freight charges have been prepaid by customer. TN or the distributor shall, at its option, either (i) repair such goods free of charge if warranty within two years, (ii) repair such goods at a minimum of $100 (One Hundred dollars) per item if warranty expired, (iii) replace such goods free of charge, or (iv) accept the return of such goods and credit current price therefore to the customer.
THIS IS THE EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. IN NO EVENT SHALL TN BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER FOR BREACH OF ANY WARRANTY, FOR BREACH OR REPUDIATION OF ANY OTHER TERM OR CONDITION OF SALE, FOR NEGLIGENCE , ON THE BASIS OF STRICT LIABILITY, CONTRACT, OR OTHERWISE AND IRRESPECTIVE OF WHETHER TN IS INFORMED BY CUSTOMER OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE OF THIS SALE.
The sole purpose of this remedy shall be to provide the customer with the replacement or repair of non-conforming goods in the manner provided here-in. This exclusive remedy shall not be deemed to have failed of its essential purpose so long as TN is willing and able to repair or replace the non-conforming goods or refund the purchase price therefore in the manner provided herein.
TN reserves the right to inspect products claimed to be defective under warranty either at the customer’s location or at TN's plant. TN assumes no liability for labor charges incidental to the adjustment, service, repairing, removal or replacement of the product or other costs, or the expense of repairs made outside of its factory except when made pursuant to TN's prior written consent. All returns must be received in the same condition as the original shipment.
LANMaster T8
18
1
8-Port Ethernet Hub w/SIC Slot
1. INTRODUCTION
This guide is intended for the system or network administrator responsible for installing and monitoring a TRANSITION Networks LANMaster T8 8-Port Ethernet Hub w/SIC Slot. A working knowledge of local area network (LAN) operations, including familiarity with communications protocols used on interconnected LANs, is assumed.
The LANMaster T8 Hub w/SIC Slot
The LANMaster T8 8-Port Ethernet Hub w/SIC Slot (E-TBT-HB-
0802), is a stand-alone, fully functional Ethernet repeater.
LANMaster T8 8-Port Ethernet Hub w/SIC Slot Features
Media Dependent Interface (MDI) switch eliminates need for RJ-45 crossover cable connection between LANMaster T8 devices.
Comes with internal power supply.
Complies with Ethernet 802.3.
Slide-In Card (SIC) slots for optional installation of additional media connections.
10BaseT Cable Specifications
The physical characteristics of the 10BaseT cable must meet or exceed IEEE 802.3 10BaseT specifications.
Either shielded or unshielded twisted pair can be used. Level 3 wire or better is recommended.
• Gauge. . . . . . . . . . . . . . . . . . 26 to 22 AWG
• Attenuation . . . . . . . . . . . . . Less than 11.5 dB @ 5-10 MHz
• Differential Characteristic . . 85 -110 Impedance @ 10 MHz
• Maximum Distance . . . . . . . 100 Meters (330 Feet)
Segment Distance
Media Maximum Maximum Minimum Maximum Segment Number Segment Medium Medium Type MAU/ Length Propagation End to End
Segment (meters) Velocity
Propagation Delay/Segment
10Base5 100 500 0.77 c 2570 10Base2 30 185 0.65 c 950
AUI
††
1 DTE/MAU 50 0.65 c 257
10BaseT 2 100
†††
0.59 c 1000
FOIRL 2 1000
††††
0.66 c 5000
FL 2 2000 0.66 c 5000
c = 3 x 108meters/second
††
AUI connection is not a segment
†††
Maximum segment length depends on the cable characteristics
††††
A network of four repeaters and five segments, can have up to 3 coax segments and 2 required link segments. The maximum length of a FOIRL link segment must not exceed 500 meters. If your network has three repeaters and four segments, the maximum length of a FOIRL link segment must not exceed 1000 meters.
LAN Master T8
TRANSITION
Minneapolis, MN 55344 USA
8 Port Ethernet Hub w/SIC Slot
1 2345678
networks
MDI/MDIX