Transition Networks E-TBT-FRL-N-02 User Manual

Page 1
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Cable Specifications . . . . . . . . . . .4
Technical Specifications . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8
User’s Guide
PCI Media Converter
• Ethernet
• Copper to Fiber
• 10Base-T to 10Base-FL
Transition Networks E-TBT-FRL-N-02 series media converters are 10Base-T/10Base-FL devices that connect 10Base-T copper to 10Base­FL fiber. The E-TBT-FRL-N-02 is PCI (Peripheral Component Interconnect) powered; designed to install directly in a PC workstation or file server, and insert into any slot on a standard PCI. No additional power supply is needed since each PCI slot has power.
Part Number Port One - Copper
10Base-T
Port Two - Fiber-Optic 10Base-FL
E-TBT-FRL-N-02
RJ-45 100 m (328 ft)*
ST, 850 nm multimode 2 km (1.2 miles)*
E-TBT-FRL-N-02 (SC)
RJ-45 100 m (328 ft)*
SC, 850 nm multimode 2 km (1.2 miles)*
E-TBT-FRL-N-02 (MT)
RJ-45 100 m (328 ft)*
MT-RJ, 850 nm multimode 2 km (1.2 miles)*
* Typical maximum cable distance. Actual distance is dependent upon the physical
characteristics of the network installation.
Page 2
Installation
Set the LinkAlert™ switch
The LinkAlert switch is located on the edge of the printed circuit board and can be easily switched to ENABLE or DISABLE without the use of tools.
The LinkAlert feature allows the media converter to monitor the fiber and copper RX (receive) ports for signal losses. In the event of a loss of an RX signal, the media converter will automatically disable the TX (transmit) signal, thus “passing through” the link loss. The far-end device is automatically notified of the link loss, which prevents the loss of valuable data unknowingly transmitted over an invalid link.
Note: If all network devices attached to the media converter(s) are capable of auto-
negotiation, enable the LinkAlert feature on the media converter(s). Otherwise, disable the LinkAlert feature.
Install the slide-in-module
To install the E-TBT-FRL-N-02 media converter slide-in-module:
1. Locate an empty slot on the PC workstation or file server.
2. Remove the screws holding the cover to the slot. Retain the screws.
3. Carefully slide the slide-in-module into the slot, aligning the module with the installation guides.
4. Ensure that the module is firmly seated in the slot.
5. Using the screws from step 2, secure the module to the workstation or file server housing .
E-TBT-FRL-N-02
2
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
4
1
Media
Converter A
Media
Converter B
Near-End
Device
Far-End Device
original fault
on the copper link
media converter B
disables the copper link
media converter A
disables the fiber TX link
3
2
media converter B
loses the fiber RX link
Installation -- Continued
Install the copper cable
1. Use the enclosed 10Base-T compliant copper cable with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the E-TBT-FRL-N-02 media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (network
interface card (NIC), terminal device, transceiver, switch, workstation, etc.).
Install the copper cable
1. Locate or build 10Base-FL compliant fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the E-TBT-FRL-N-02 media converter as described:
Connect the male TX cable connector to the female TX port.
Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
Connect the male TX cable connector to the female RX port.
Connect the male RX cable connector to the female TX port.
Power the media converter
The E-TBT-FRL-N-02 media converter is powered by the PCI (Peripheral Component Interconnect) edge connector on the circuit board.
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Connect the fiber cable to the media converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
RJ-45 port
on the media
converter
RJ-45 port
on the network
t
erface card (NIC)
E-TBT-FRL-N-02
Page 3
Operation
LED indicators
After installation, the media converter should function without operator intervention. Use the status LEDs to monitor the media converter operation in the network.
PLink (Fiber) ON = A 10Base-FL link and normal operation.
OFF = A lack of power or a downed 10Base-FL link.
Link (TBT) ON = A 10Base-T link and normal operation.
OFF = A lack of power or a downed 10Base-T link
AutoCross™
The AutoCross feature detects and configures the twisted-pair copper port on the media converter to the correct straight-through (MDI) or crossover (MDI-X) configuration. This feature allows either MDI or MDI-X cable to connect the media converter to devices such as hubs, transceivers, or network interface cards (NICs).
Cable Specifications
Fiber cable
Bit Error Rate: <10-9 Multimode fiber (recommended): 62.5/125 µm
E-TBT-FRL-N-02 E-TBT-FRL-N-02(SC) E-TBT-FRL-N-02(MT) 850 nm multimode Fiber-optic Transmitter Power: min: -20.0 dBm max: -10.0 dBm Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -7.2 dBm Link Budget 12.5 dB
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.
E-TBT-FRL-N-02
4
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Cable Specifications -- Continued
Copper cable
Category 3: (minimum requirement)
Gauge 24 to 22 AWG Attenuation 11.5 dB/100m @ 5-10 MHz
Category 5: (recommended)
Gauge 24 to 22 AWG Attenuation 22.0 dB/100m @ 100 MHz
• Straight-through twisted-pair cable must be used.
• Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Straight-Through Cable
T
wisted Pair #1
T
wisted Pair #2
1 2
3 6
1 2
3 6
Crossover Cab
le
Twisted Pair #1
Twisted Pair #2
1 2
3 6
1 2
3 6
Technical Specifications
For use with Transition Networks Model E-TBT-FRL-N-02 or equivalent
Standards: IEEE 802.3™
Data Rate: 10 Mb/s
Dimensions: 4.762” x 5.208” x 0.932” (121mm x 134mm x 24mm)
Weight: 3 oz. (91g approximately)
Power Consumption: <450 mA
Environment: Operating temp Tmra*: 0°C to 50°C (32°F to 122°F ) Storage temp: -25°C to 85°C (-13 to 185°F ) Humidity: 10% to 90%, non-condensing Altitude: 0 to 10,000 feet
Warranty: Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module depends on the physical characteristics and the installation configuration of the file server or PC workstation in which this slide-in-module will be installed.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and Invisible Laser Radiation When Open. DO NOT STARE into laser Beam or view it directly with optical Instruments. Failure to observe this caution could result in loss of vision.
CAUTION:
Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
E-TBT-FRL-N-02
Page 4
E-TBT-FRL-N-02
6
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Troubleshooting
If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the PWR (power) LED illuminated? NO
Confirm that the media converter is properly inserted into the PC
workstation or the file server.
Confirm that the PC workstation or the file server is properly connected to
the power source and is turned on.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
Proceed to step 2.
2. Is the RJ-45 LINK LED illuminated? NO
Check the twisted-pair cables for proper connection.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
Proceed to step 3.
3. Is the fiber LINK LED illuminated? NO
Check the fiber cables for proper connection.
Verify that the TX and RX cables on the media converter are connected to
RX and TX ports, respectively, on the other device.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
Proceed to step 4.
4. Is the RJ-45 RX LED illuminated? NO
Disconnect and reconnect the 10Base-T cable to restart the initialization
process.
Restart the attached device to restart the initialization process.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
Proceed to step 5.
5. Is the fiber RX LED illuminated? NO
Disconnect and reconnect the 10Base-FL cable to restart the initialization
process.
Restart the attached device to restart the initialization process.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
E-TBT-FRL-N-02
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
7
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
Model: E-TBT-FRL-N-02 Series Media Converter
Part Number: E-TBT-FRL-N-02, E-TBT-FRL-N-02(SC), E-TBT-FRL-N-02(MT)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the E-TBT-FRL-N-02 to which this declaration refers is in conformity with the following standards.
EN 55022:1998+A1:2000 Class A; EN 55024:1998; FCC Part 15 Subpart B; UL 1950, 21CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
Novembler 28, 2005_____
Stephen Anderson, Vice-President of Engineering Date
Contact Us
Technical support
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff. techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, U.S.A. Telephone: 952-941-7600 Toll free: 800-526-9267 Fax: 952-941-2322
Page 5
Trademark notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright restrictions © 2003-2004 Transition Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means
- graphic, electronic, or mechanical - without written permission from Transition Networks.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark
FCC regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.
Printed in the U.S.A. 33352.A