Canadian Regulations ............................................................................................... 59
European Regulations .............................................................................................. 59
Record of Revisions ...................................................................................................... 60
Contact Us .................................................................................................................... 61
#
Description
EO2PSE4052-111
(Local)
One 10/100/1000Base-T RJ-45 or one 100/1000Base-X SFP Combo Port and
one 10/100/1000Base RJ-45 or 2-Wire Terminal Block Combo Port; PSE.
EO2PD4052-111
(Remote)
One 10/100/1000Base-T RJ-45 or 2-Wire Terminal Block Combo Port and
one 10/100/1000Base-T IEEE 802.3af/at or one100/1000Base-X SFP Combo
Port; PD and PSE for connected IP device.
25148
Power Adapter
Optional 90W Industrial Power Supply provides power for Local Unit and can
be used optionally at the Remote Unit for redundant power. 90 ~ 264 VAC;
127 ~ 370 VDC. (Sold separately; country specific power cord included.)
RMS19-SA4-02
Optional 4-Slot Media Converter Shelf
WMBL
Optional 4″ Wall Mount Kit (long); sold separately.
WMBD
Optional 5" [127 mm] DIN Rail Mount Bracket; sold separately.
WMBD-F
Optional 3.3” [84 mm] DIN Rail Mount Bracket (flat); sold separately.
WMBV
Optional 5" [127 mm] Vertical Mount; sold separately.
Introduction
Transition Networks' Ethernet Over 2-Wire Extenders with PoE+ (EO2P) are used in pairs, with a
local or remote device at opposite ends of the UTP cable. The extenders are the most flexible in
the market, with a 10/100/1000Base-T RJ-45 connector or 100/1000Base-X SFP combo port
allowing connection to either copper or fiber Ethernet devices. The Local device provides a
Gigabit 2-wire terminal block or RJ-45 connection to provide SELV power over twisted pair cable
to the Remote device. The Remote device receives data and power through the 2-wire terminal
block or RJ-45 connection and provides either a 100/1000Base-X SFP or 10/100/1000Base-T RJ-45
connector output with PoE+ power for IP cameras, wireless access points or other PoE powered
end devices. Power for the Local device can be supplied through a +48VDC power source that
meets IEEE 802.3af/at isolation requirements of 1500VAC or 2200VDC or through the designated
90 Watt power adapter. The designated 90 Watt power adapter is optional at the Remote device
for additional power or for providing redundant power.
Transition Networks EO2P are a flexible and cost-effective way to extend Ethernet networks at
near Gigabit speeds and provide full PoE+ power to security cameras, wireless access points or
other IP end devices at distances beyond the typical 100m Ethernet cable limitation.
The EO2P leverage the existing 18-24 AWG unshielded twisted pair (CAT6/5, CAT3, or 2-wires of
other 18-24 AWG UTP cable) cabling infrastructure to provide data and safety extra low voltage
(SELV) power to IP/Ethernet devices in remote locations, saving time and money over installing
new cable and electric power when upgrading or extending networks.
Ordering Information
Note: Extenders must be used in pairs. A properly isolated power source is required for each Local
unit and an external power supply is optional for Remote units depending on power requirements.
Application Examples
The Ethernet Over 2-Wire Extenders with PoE+ allow utilization of existing 18-24 AWG
unshielded twisted pair (CAT5, CAT3 and other 2-wire cabling) for:
Extending network connectivity and power to IP devices such as wireless access
points (WAPs) or VoIP phones,
Bridging between two networks using a 2-wire infrastructure,
Conversion of analog surveillance systems to IP-based cameras, and more.
Extending Network Connectivity and Power to IP Devices
The figure below shows multiple usage scenarios. The Ethernet over 2-Wire Extenders
With PoE+ are flexible for use in most networks, offering both copper and fiber
connections.
Features
Features
Copper or fiber combo Ethernet port
IEEE 802.3af/at compliant Remote PoE+ port for powering cameras or other remote
devices
Full PoE+ at 335-1500 ft. over a single pair or 1500-6800 ft. over multiple pairs
(dependent on cable type). To determine power and distance for specific cable
types, refer to the online calculator at https://www.transition.com.
Half-Gigabit Ethernet speeds over UTP cable at distances of 660 feet (200m) or Fast
Ethernet speeds at 2000 feet (610m) (dependent on wire gauge). (Typical 24 AWG
cable DC resistance of 20 ohm per 1000 ft. Cable with less DC resistance may
increase distance.)
Web browser configurable; Web-based management of both local and remote
Plug-and-Play installation
Field upgradeable firmware
Can be managed through a single IP address
Auto MDI/MDI-X
128 Bit AES encryption over 2-wire
IPv4 and IPv6 supported
Client for DHCP, DNS, NTP
Maximum frame size 1518 bytes
• Proprietary 2-wire SELV end device classification prevents power delivery to
unintended devices.
• Power monitoring allows user to determine power available at the remote device
over different cable lengths.
• Auto Power Reset (APR): PoE+ connected device can be monitored and power
cycled/rebooted in the event it becomes unresponsive.
• Reverse polarity protected, but does not support telco -48V (positive connection to
earth ground).
Device Views
EO2PSE4052-111 (Local PSE Unit)
EO2PD4052-111 (Remote PD Unit)
Package Contents
Carefully unpack the contents of your order and verify you have ordered and received all required
items:
One EO2PD4052-111 Remote PD Unit and:
o four rubber feet
o printed Quick Start Guide
o one 2-Position Terminal Block Plug Option (TN 28993)
o one 2-Position Terminal Block Plug Option (TN 28992)
One EO2PSE4052-111 Local PSE Unit and:
o four rubber feet
o printed Quick Start Guide
o one 2-Position Terminal Block Plug Option (TN 28993)
o one 2-Position Terminal Block Plug Option (TN 28992)
One 25148 90W Power Adapter
o includes country-specific power cord
Save the packaging for possible future use.
Related Information
A printed Quick Start Guide is shipped with each EO2P unit. A full User Guide manual is available
online. Related manuals include:
For Transition Networks Drivers, Firmware, etc. go to the Product Support webpage (logon
required).
For Transition Networks Application Notes, Manuals, Brochures, Data Sheets, Specifications,
etc. go to the Support Library (no logon required).
For SFP manuals and other information see Transition Networks SFP page.
Installation
Install Cautions and Warnings
Elevated Operating Ambient: If installed in a closed cabinet, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Installation of the equipment should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical Loading: Mounting of the equipment should be such that a hazardous condition
is not achieved due to uneven mechanical loading. Do not place any equipment on top of a
rack-mounted unit.Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Inter-building and Protection Requirements: These products incorporate surge
protection.
Not Designed for Use in Life Support Equipment or Applications: These products are
not designed for use in life support equipment or applications that would cause a lifethreatening situation if any such product failed. Do not use this product in these types of
equipment or applications.
Export Rules: With respect to the product described herein, the user or recipient, in the
absence of appropriate U.S. government authorization, agrees:
1) Not to re-export the or release any such information consisting of technology,
software or source code controlled for national security reasons by the U.S. Export
Control Regulations (“EAR”), to a national of EAR Country Groups D:1 or E:2;
2) Not to export the direct product of such technology or such software to EAR Country
Groups D:1 or E:2, if such technology or software and direct products thereof are
controlled for national security reasons by the EAR; and
3) In the case of technology controlled for national security reasons under the EAR
where the direct product of the technology is a complete plant or component of a plant,
not to export to EAR Country Groups D:1 or E:2 the direct product of the plant or major
component thereof, if such direct product is controlled for national security reasons by
the EAR, or is subject to controls under the U.S. Munitions List (“USML”).
At all times hereunder, the recipient of such information agrees that they shall be
deemed to have manually signed this document in connection with their receipt of any
such information.
Mounting Options
Several mounting options are available; please note the following:
Install the EO2Pxx4052-111 units indoors (or in an appropriately rated enclosure).
Securely mount the EO2Pxx4052-111 units.
Do not support the EO2Pxx4052-111 units by the attached cables.
Use an optional wall mounting bracket or rack mount shelf (ordered separately).
Mount an EO2Pxx4052-111 unit onto a DIN rail using an optional DIN Rail Mount Kit
(ordered separately).
Desktop
Install the four rubber feet on the bottom of the EO2Pxx4052-111 units.
DIN Rail
For DIN Rail mounting, the following bracket options can be used:
WMBD - 5" DIN Rail Mount Bracket
WMBD-F 3.3" DIN Rail Mount Bracket (Flat)
Wall Mount
For wall mounting, the following bracket options can be used:
WMBL - 4" Wall Mount Bracket
WMBV - 5" Vertical Mount Wall Mount Bracket
RMS19-SA4-02 Shelf Mount
For mounting up to four EO2P units use the optional RMS19-SA4-02 4-Slot Media Converter
Shelf.
See the related manual for DIN Rail, Wall Mount, or Shelf specifications and procedures.
Port Descriptions
The extenders leverage existing 18-24 AWG unshielded twisted pair (CAT 5, CAT 3 and
other 2-wire phone wire) cabling infrastructure to extend the Ethernet network at near
Gigabit speeds and provide data and power to IP devices in remote locations.
These extenders are used as a pair of devices, with a local and remote unit at opposite ends of
the 2 Wire cable. The local unit can accept a 10/100/1000Base-T RJ-45 or 100/1000Base-X SFP
connection. The local device also provides a 2 Wire connection with power over two-wire.
The remote device can be powered by the 2 Wire Power connection and provides a PoE+
10/100/1000Base-T RJ-45 connection, or a 100/1000Base-X SFP connection.
Connections
This section illustrates and describes connecting the EO2PSE4052-111 (Local PSE unit with
GB combo RJ45/SFP and 2 Wire) to the EO2PD4052-111 (Remote PD unit with 2 Wire and
GB combo RJ45 PoE+/SFP).
EO2PSE4052-111 EO2PD4052-111
Local PSE Unit Remote PD Unit
NetworkConnection
The EO2PSE4052-111 offers a Combo (Shared) port for connecting to either copper or
fiber network equipment.
In terms of copper versus fiber port selection / priority, only one port can be active at
any given time; by default the SFP port takes precedence over the copper port (configurable on the Ethernet Web GUI page).
SFP / Fiber Connection
The SFP port supports any MSA compliant 100/1000Base-X SFP module. For
temperatures above +50 C, industrial (+85 C) SFP modules must be used.
Installing SFP Devices
The EO2P lets you install a SFP device of your choice in order to make a fiber
connection. The EO2P has a single SFP port.
SFP Installation
Transition Networks SFPs are small form factor, hot-pluggable transceivers which allow
for a single piece of network equipment to be connected to a multitude of interfaces,
protocols, and transmission media via the SFP port. All Transition Networks SFPs are
compliant with the Multi-Sourcing Agreement (MSA) ensuring interoperability with all
other MSA compliant networking devices. See SFF-8472 Specification for details.
See the SFP manual for important Safety cautions and warnings.
To install an SFP device in the EO2P:
1. Position the SFP device at the open SFP slot, with the label facing up.
2. Carefully slide the SFP device into the slot, aligning it with the internal installation
guides.
3. Ensure that the SFP device is firmly seated against the internal mating connector.
4. Connect the fiber cable to the fiber port connector of the SFP device (see above).
See the TN SFP/XFP Optical Transceivers web page for the latest information.
Connecting Two-strand Fiber Cable
A duplex fiber cable consists of two strands of glass or plastic fiber. Typically found in a “zipcord”
construction format, this cable is most often used for duplex communication between devices
where a separate transmit and receive are required.
1. Locate a 100/1000Base-X compliant fiber cable with male, two-stranded TX to RX connectors
installed at both ends.
2. Connect the fiber cables to the EO2P’s 100/1000Base-X fiber port as described below:
• Connect the male TX cable connector to the female TX connector.
• Connect the male RX cable connector to the female RX connector.
3. Connect the fiber cables to the 100/1000Base-X fiber port on the other EO2P:
• Connect the male TX cable connector to the female RX connector.
• Connect the male RX cable connector to the female TX connector.
For information on available SFP modules, see the Transition Networks Small Form factor
Pluggables webpage. For information on specific SFP characteristics, unpacking, installation,
connecting, and removing see the specific SFP User Guide.
Connecting Single-strand Fiber Cable
Single fiber (simplex) technology helps maximize the usage of a limited number of fiber runs.
In a traditional optical link, a fiber pair consists of two uni-directional strands. Single fiber
technology multiplexes two optical wavelengths of 1310nm and 1550nm into a single strand fiber.
In a single fiber EO2P each wavelength is responsible for either the transmit or the receive
function. Consequently, the bi-directional transmission is achieved by using a single strand.
The EO2Ps in a single fiber scenario "match" each other's wavelengths. For example, one EO2P
transmits at the wavelength of 1310nm and receives at 1550nm while the other EO2P transmits
at 1550nm and receives at 1310nm. The EO2Ps are used in pairs.
1. Locate or build IEEE 803.2™ compliant 1000Base-X fiber cable with a male, single-strand LC
connector installed at each end.
2. Connect the fiber cable to the EO2Ps.
3. Connect the fiber cable to the other device (another EO2P, hub, etc.).
Local Power Source
Remote POE-PSE
Power Out
Power at PD
DIN or TB (48V@45W)
802.3at - Class 4
30 W
25.5W
Ethernet Cable Connection
Connect the EO2PSE4052-111 RJ45 Ethernet jack to the EO2PD, camera or other network
equipment using a standard Ethernet cable.
Power over Ethernet
Using the PoE option, the EO2Pxx4052-111 can automatically enable delivery of up to 25.5
watts of POE (IEEE 802.3at - Class 4) to compatible network devices, via its Ethernet port.
-OR-
Using the PoE option, the EO2PSE4052-111 can automatically enable delivery of up to 30
watts of power to the EO2PD4052-11. The EO2PD4052-111 can supply up to 25.5 Watts of
PoE (IEEE 802.3at-class) power to a connected powered device.
Installing the RJ-45 Copper Cable - 10/100/1000Base-T Copper Port
1. Locate a 10/100/1000Base-TX compliant copper cable with male RJ-45 connectors
installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the EO2Pxx4052-111
10/100/1000Base-RJ-45 port.
3. Connect the RJ-45 connector at the other end of the cable to the 10/100/1000Base-RJ-
45 port on the other device (camera, wireless access point, etc.).
IMPORTANT: Copper based media ports such as Twisted Pair (TP) Ethernet, USB, RS232,
RS422, RS485, DS1, DS3, Video Cat 3/Cat5, etc., are intended to be connected to link
segments that are not subject to lightening transients or power faults.
Warning: Do not plug a network cable into the Power Out or Power In RJ-45 jacks.
Plugging a network cable into the RJ-45 PoE port with a 2-wire cable already connected is
not supported.
Two Wire Connection(Local to Remote Unit)
Connect the EO2PSE4052-111 unit’s 2-wire connector to the 2-wire cable. The 2-wire
connector should only be used to connect a Local unit to a Remote unit. The EO2Pxx4052111 is not compatible with other equipment such as analog video amplifiers.
Grounding
An earth ground chassis stud is provided on the back panel. Note that bonding the earth
ground to the chassis stud will improve circuit protection.
2-Wire Connection Options
Both 2-Wire options are shown and described below. Both are keyed slide-in options that are not
screwed into the 2-Wire connector. Note the polarity for both options.
2 Position Terminal Block Plug Option (TN 28992)
The provided 2 Position Terminal Block is a Female Socket 0.138"
(3.50mm) 180° Free Hanging (In-Line) squeeze-type Plug (TN 28992) as
shown right. Squeeze the sides, insert the Terminal Block (slotted tabs up),
insert each of the two wires (note the polarity) and use a small slotted
screwdriver to tighten the wires.
2 Position Terminal Block Plug Option (TN 28993)
The provided 2 Position STR Terminal Block is a Female Socket 0.138"
(3.50mm) 180° Free Hanging (In-Line) Plug (TN PN 12111) as shown right.
Insert the Terminal Block (slotted tabs up), insert each of the two wires
(note the polarity) and use a small slotted screwdriver to tighten the wires.
Back Panel DevicePower Options
The EO2P back panel provides a +48 VDC IN option and a 4-Pin Mini DIN Power option.
You can connect one or the other or both. Having both power options connected does not
provide redundancy/failover.
The EO2P back panel +48 VDC IN option and the 4-Pin Mini DIN Power option are described
in the following sections.
48 VDC IN Options
Local (EO2PSE4052-111) Power Input Options
The power input options for the EO2PSE4052-111 (Local PSE unit) devices are:
1. 4-Pin mini DIN with the designated AC to DC adapter OR
2. 2-Pin Terminal Block connectors for +48 VDC power source that must meet IEEE 802.3 af/at
isolation requirements of 1500VAC or 2250 VDC. Note: this must be +48 VDC IN.
Remote (EO2PD4052-111) Power Input Options
The power input option for the EO2PD4052-111 (Remote PD unit) devices are:
1. 4-Pin mini DIN with the designated AC to DC adapter OR
2. 2-Pin Terminal Block connectors for +48 VDC power source that must meet IEEE 802.3 af/at
isolation requirements of 1500VAC or 2250 VDC. OR
3. PoE input power to the Remote from the Local via the Cat 3/Cat5 cable.
The two options for 48 V DC input to the EO2P units are shown and described below:
Note: the Black Power Plug with Retention is for back panel unit power only; do not try
to use it for the front panel 2 Wire connection.
4-Pin Mini DIN Power Option
The 48VDC IN 4-Pin Mini DIN power input option is shown and described below.
Note: grip the power supply cable from the 48VDC IN 4-Pin Mini DIN connection with
the flat-topped grip facing up; you will notice a slight slide before disconnection.
Do not try to pull the connector from the 4-Pin Mini DIN by the cord itself as damage
may occur.
Local PSE Unit Delivery of PoE to Remote (End) Device
If the remote end device (e.g., camera) does not need PoE, the remote unit does not
provide PoE. If you do not want PoE power from the Remote unit to the connected
remote (end) device, enable Auto Power Reset, select PoE Power Down mode, and ping
an unused IP address on the subnet. Once it times out, PoE power will be disabled until
you use the pulldown on the Auto Power Reset page on page 36.
Operation
Web GUI Configuration
Web Browsers Supported
Current versions of most web browsers are supported.
The default IP address is 192.168.0.1.
The default password is admin. The factory reset login is betera (not
currently configurable).
Web Configuration Pages
The web UI lets you access the Login page and subsequently the various
Configuration pages (2 Wire, IP, Ethernet, Device, Auto Power Reset, Advanced) and Status
pages (Power, with and without Auto Update), SFP (with and without Auto Update), and
Remote Upgrade Status, and Help pages as described below.
Login page
The Login page requires password access to the web pages.
Authentication Password: This unit is password protected. The default password is admin.
Please enter the correct password to access the web pages. Click the Ok button when done.
The 2 Wire page then displays, as described in the next section. Note: Transition Networks
strongly recommends you change your password immediately for security purposes. Transition
Networks is not responsible for damages incurred due to insecure password protection.
Buttons
Ok: Click the Ok button to access the web pages if the password is accepted.
Cancel: Click the Cancel button to negate the Password entry.
Web browser Timeout: 1 hour inactivity timer, after which you must log back in to the EO2P
Web GUI.
Loading...
+ 42 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.