Transition Networks E-100BTX-FX-05SC, E-100BTX-FX-05LH, E-100BTX-FX-05SMLC, E-100BTX-FX-05XL, E-100BTX-FX-05LW User Manual

...
USER’S GUIDE
E-100BTX-FX-05
Stand-Alone Media Converter
• Fast Ethernet™
• Copper to Fiber
• 100Base-TX to 100Base-FX
• Extended Temperature
Transition Networks E-100BTX-FX-05 Fast Ethernet™ Media Converter connects 100Base-TX shielded or unshielded twisted-pair copper cable to 100Base-FX fiber-optic cable.
The E-100BTX-FX-05 series of Media Converters include both standard temperature and extended temperature models. (Part numbers for the extended temperature models are listed on page 2.)
Standard Temperature Models:
* Typical maximum cable distance. (Actual distance is dependent upon the physical characteristics of the network installation.)
Installation . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . .5
Cable Specifications . . . . . . . . . . .7
Technical Specifications . . . . . . . .9
Fault Isolation and Correction . .10
Contact Us . . . . . . . . . . . . . . . . .11
Compliance Information . . . . . . .12
Part Number Port One - Copper
100Base-TX
Port Two - Duplex Fiber-Optic 100Base-FX
E-100BTX-FX-05 RJ-45
100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
E-100BTX-FX-05(SC) RJ-45
100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
E-100BTX-FX-05(MT) RJ-45
100 m (328 ft)*
MT-RJ, 1300 nm multimode 2 km (1.2 miles)*
E-100BTX-FX-05(SM) RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode 20 km (12.4 miles)*
E-100BTX-FX-05(SMLC) RJ-45
100 m (328 ft)*
LC, 1310 nm singlemode 20 km (12.4 miles)*
E-100BTX-FX-05(LH) RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode 40 km (24.9 miles)*
E-100BTX-FX-05(XL) RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode 60 km (37.3 miles)*
E-100BTX-FX-05(LW) RJ-45
100 m (328 ft)*
SC, 1550 nm singlemode 80 km (49.7 miles)*
2
E-100BTX-FX-05
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
The Media Converters with the “HT” extension in the part number can be put into service in an extended termperature environment from -25°C to 65°C (-13°F to 149°F).
Standard Temperature Models:
* Typical maximum cable distance. (Actual distance is dependent upon the physical characteristics of the network installation.)
Optional Accessories (sold separately)
Part Number Description
E-MCR-03 12-Slot Media Converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
WMBL Optional Wall Mount Brackets
Length: 4.0 in. (102 mm), Fits converter length: 4.7 in. (119 mm)
SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone Wide-
Input; Output: 12.6VDC, 1.0 A
SPS-1872-CC Optional External Power Supply; 18-72VDC Piggy-Back Wide-
Input; Output: 12.6VDC, 1.0 A
Part Number Port One - Copper
100Base-TX
Port Two - Duplex Fiber-Optic 100Base-FX
E-100BTX-FX-05(HT) RJ-45
100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
E-100BTX-FX-05(SCHT) RJ-45
100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
E-100BTX-FX-05(SMHT) RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode 20 km (12.4 miles)*
E-100BTX-FX-05(LHHT) RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode 40 km (24.9 miles)*
E-100BTX-FX-05(XLHT) RJ-45
100 m (328 ft)*
SC, 1310 nm singlemode 60 km (37.3 miles)*
E-100BTX-FX-05(LWHT) RJ-45
100 m (328 ft)*
SC, 1550 nm singlemode 80 km (49.7 miles)*
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
3
INSTALLATION
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the 4-position switch and jumper. Failure to observe this caution could result in damage to, and failure of, the Media Converter.
4-Position Switch
The 4-position switch is located on the side of the Media Converter. Use a small flatblade screwdriver or a similar device to set the recessed switches. Refer to the drawing to the right for the locations of the four individual switches.
1. Auto-Negotiation
UP Enables Autonegotiation for the copper connection (see page 5). DOWN Disables Autonegotiation for the copper connection.
2. Pause Control Frame
UP Enables Pause Control (see page 6). DOWN Disables Pause Control.
3. Link Pass-Through
UP Enables Link Pass-Through (see page 6). DOWN Disables Link Pass-Through.
4. Far-End Fault
UP Enables Far-End Fault (see page 6). DOWN Disables Far-End Fault.
AutoCross™ Jumper
The AutoCross™ feature allows either straight-through (MDI) or crossover (MDI-X) cables to be used when connecting to devices such as hubs, transceivers, or network interface cards (NICs). AutoCross™ determines the characteristics of the cable connection and automatically configures the unit to link up, regardless of the cable configuration.
The jumper is located on the circuit board inside the Media Converter housing. To set the jumper:
1. Using a small screwdriver, remove the four (4) screws that secure the cover and carefully remove the cover from the Media Converter.
2. Locate the J3 jumper on the circuit board and using small needle-nosed pliers or similar device, move the jumper to the desired position. (Refer to the drawing to the right.)
3. Carefully replace the cover on the Media Converter and replace the four (4) screws that secure the cover to the Media Converter.
Link Pass-Through (UP=ON)
Pause (UP=ON)
A
uto-Negotiation (UP=Enabled)
Far End Fault (UP=ON)
1234
Disable AutoCross
Enable AutoCross
J 3
J 3
4
E-100BTX-FX-05
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
INSTALLATION -- Continued
Installing the Cable
FIBER
1. Locate or build 100Base-FX compliant fiber cable with male, two­stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the Media Converter as described:
• Connect the male TX cable connector the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another Media Converter, hub, etc.) as described:
• Connect the male TX cable connector the female RX port.
• Connect the male RX cable connector to the female TX port.
COPPER
1. Locate or build 100Base-TX compliant copper cables with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the Media Converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.).
Connect the fiber cable to the Media Converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
RJ-45 port
on the Media
Converter
RJ-45 port
on the other device
(switch, work station, etc.)
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
5
INSTALLATION -- Continued
Power the Media Converter
AC
1. Install the power adapter cord to the back of the Media Converter.
2. Connect the power adapter plug to AC power.
3. Verify that the Media Converter is powered by observing the illuminated LED power indicator light.
DC
Consult the User’s Guide for the Transition Networks SPS1872-xx DC External Power Suppy for powering the Media Converter.
OPERATION
Using Status LEDs
Use the status LEDs to monitor the E-100BTX-FX-05 Media Converter operation in the network.
Power Illuminated green LED indicates connection to external AC power.
SDF Signal Detect/Fiber: Steady green LED indicates the fiber port is
connected to the device.
SDC Signal Detect/Copper: Steady green LED indicates the RJ-45
twisted-pair copper port is connected to the device.
RXC Receive/Copper: Flashing green LED indicates the packets are seen
on the twisted-pair copper RJ-45 port.
RXF Receive/Fiber: Flashing green LED indicates the packets are seen
on the fiber port.
Auto-Negotiation
When the Auto-Negotiation feature is activated (see page 3), the Media Converter brings up the copper links in the highest speed and mode possible for all the attached network devices.
NOTE: The E-100BTX-FX-05 series Media Converter does NOT support rate conversion between 10Mb/s, 100Mb/s, and 1000Mb/s network devices.
RX
TX
Fiber
UTP/STP
Power
RXC
RXF
SDF
SDC
Loading...
+ 4 hidden pages