Transition Networks E-100BTX-FX-05 100, E-100BTX-FX-05 103, E-100BTX-FX-05 101, E-100BTX-FX-05 102 User Manual

USER’S GUIDE
E-100BTX-FX-05(10x)
Stand-Alone Media Converter
• Fast Ethernet
• Copper to Single Fiber
• 100Base-TX to 100Base-FX
Transition Networks E-100BTX-FX-05(10x) Fast Ethernet Media Converter connects 100Base-TX shielded or unshielded twisted-pair copper cable to single connector 100Base-FX fiber-optic cable.
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Cable Specifications . . . . . . . . . . .7
Technical Specifications . . . . . . . .9
Fault Isolation and Correction . .10
Contact Us . . . . . . . . . . . . . . . . .11
Compliance Information . . . . . . .12
* Typical maximum cable distance. (Actual distance is dependent upon the
physical characteristics of the network.) (TX) = transmit (RX) = receive
** E-100BTX-FX-05(100)
and (101) are intended to be installed in the same network where one is the local converter and the other is the remote converter.
*** E-100BTX-FX-05(102)
and (103) are intended to be installed in the same network where one is the local converter and the other is the remote converter.
Part Number Port One - Copper Port Two - Simplex Fiber-Optic
E-100BTX-FX-05(100) ** RJ-45
100 m (328 ft)*
SC, 1310 nm (TX)/1550 nm (RX) singlemode, 20 km (12.4 miles)*
E-100BTX-FX-05(101) ** RJ-45
100 m (328 ft)*
SC, 1550 nm (TX)/1310 nm (RX) singlemode, 20 km (12.4 miles)*
E-100BTX-FX-05(102) *** RJ-45
100 m (328 ft)*
SC, 1310 nm (TX)/1550 nm (RX) singlemode, 40 km (24.8 miles)*
E-100BTX-FX-05(103) *** RJ-45
100 m (328 ft)*
SC, 1550 nm (TX)/1310 nm (RX) singlemode, 40 km (24.8 miles)*
2
E-100BTX-FX-05(10x)
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the 4-position switch and jumper. Failure to observe this caution could result in damage to, and failure of, the Media Converter.
4-Position Switch
The 4-position switch is located on the side of the Media Converter. Use a small flatblade screwdriver or a similar device to set the recessed switches (see the drawing to the right).
1. Auto-Negotiation
UP Advertises 100Mb/s full-duplex and half-duplex (see page 5). DOWN Disables Auto-Negotiation. The Media Converter operates at 100
Mb/s in the duplex mode (full or half) of the attached device. (This setting is primarily used when connecting to a hub).
2. Pause Control Frame
(Applies ONLY if switch 1 is UP AND the Media Converter is connected to Auto-Negotiation device(s) capable of Pause Control Frame.)
UP Enables Pause Control (see page 6). DOWN Disables Pause Control.
3. Link Pass-Through
UP Enables Link Pass-Through (see page 6). DOWN Disables Link Pass-Through.
4. Far-End Fault
UP Enables Far-End Fault (see page 6). DOWN Disables Far-End Fault.
AutoCross Jumper
The AutoCross™ feature allows either straight-through (MDI) or crossover (MDI-X) cables to be used when connecting to devices such as hubs, transceivers, or network interface cards (NICs). AutoCross determines the characteristics of the cable connection and automatically configures the Media Converter to link up, regardless of the cable configuration.
The jumper is located on the circuit board inside the Media Converter housing. To set the jumper:
1. Using a small screwdriver, remove the four (4) screws that secure the cover and carefully remove the cover from the Media Converter.
2. Locate the J3 jumper on the circuit board and, using small needle-nosed pliers or similar device, move the jumper to the desired position (see the drawing to the right).
3. Carefully replace the cover on the Media Converter and replace the four (4) screws that secure the cover to the Media Converter.
Link Pass-Through (UP=Enable)
Pause (UP=Enable)
A
uto-Negotiation (UP=Enable)
Far End Fault (UP=Enable)
1234
Disable AutoCross
Enable AutoCross
J 3
J 3
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
3
Installation -- Continued
Connect the Fiber Cable
1. Locate or build 100Base-FX compliant fiber cable with male, single­stranded simplex connectors installed at both ends.
2. Connect the simplex connector at one end of the cable to the single­strand fiber port on the first E-100BTX-FX-05(10x) Media Converter.
3. Connect the simplex connector at the other end of the cable to the single­strand fiber port on the second E-100BTX-FX-05(10x) Media Converter.
Connect the Twisted-Pair Copper Cable
1. Locate or build 100Base-TX compliant cables, with male RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the E-100BTX-FX-05(10x) Media Converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.).
Power the Media Converter
AC
1. Install the power adapter cord to the back of the Media Converter.
2. Connect the power adapter plug to AC power.
3. Verify that the Media Converter is powered by observing the illuminated LED power indicator light.
DC
Consult the User’s Guide for the Transition Networks SPS1872-xx DC External Power Suppy for powering the Media Converter.
Connect the fiber cable to the first Media Converter as shown.
Connect the fiber cable
to the second Media
Converter as shown
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port on the first
Media Converter
4
E-100BTX-FX-05(10x)
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
Operation
Status LEDs
The E-100BTX-FX-05(10x) Media Converter is designed to operate without user intervention. Use the status LEDs to monitor the Media Converter operation in the network.
Power On Connection to external AC power.
SDF On (Singal Detect/Fiber) A link has been established for
the Fiber connection.
SDC On (Signal Detect/Copper) A link has been established for
the Copper connection.
RXC Flashing (Copper Receive) The Copper connection is receiving
data.
RXF Flashing (Receive Fiber) The Fiber connection is receiving data.
Product Features
Auto-Negotiation
The Auto-Negotiation feature brings up the copper links in the highest speed and mode possible for all the attached network devices.
NOTE: The E-100BTX-FX-05(10x) series Media Converter does NOT support rate conversion between 10Mb/s, 100Mb/s, and 1000Mb/s network devices.
Pause Control Frame
The Pause Control Frame feature can improve network performance by allowing one end of the link to signal the other to discontinue frame transmission for a set period of time to relieve buffer congestion.
NOTE: If the Pause Control feature is present on ALL network devices attached to the Media Converter(s), enable the Pause Control feature on the Media Converter(s). Otherwise, disable the Pause Control feature (see page 2).
100Base-FX 100Base-TX
Power
RXC
RXF
SDF
SDC
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
5
Operation -- Continued
Product Features -- Continued
Link Pass-Through
When the Link Pass-Through feature is activated (see page 2), a fault on one side of the Media Converter stops the signal and data transmission on the other side of the Media Converter. If the Media Converter does not detect a good link on the copper side, the Media Converter disables all transmission (including active-idle) on the fiber side.
Far-End Fault
When the Far-End Fault feature is activated (see page 2), a fault on an incoming fiber link causes the Media Converter to transmit a Far-End Fault signal on the outgoing fiber link. In addition the Far-End Fault signal also activates the Link Pass-Through, which, in turn, disables the link on the copper portion of the network.
100Base-TX
Device
Media Converter
100Base-FX
Device
Original Fault
100Base-TX
Device
Media Converter
100Base-FX
Device
Original Fault
Fiber
Copper
Fiber
Copper
Fiber
Copper
Copper
(Sends a Far-End
Fault)
Media Converter
Media Converter
Fiber
Copper
Copper
Media Converter
(Sends a Far-End
Fault)
Media Converter
100Base-TX
Device
100Base-TX
Device
100Base-FX
Device
100Base-FX
Device
6
E-100BTX-FX-05(10x)
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
Operation - Continued
Product Features -- Continued
Full Duplex Network
In a full-duplex network, maximum cable lengths are determined by the type of cables that are used. See page 1 (front cover) for the cable specifications
for the different E-100BTX-FX-05(10x) models.
The 512-Bit Rule does not apply in a full-duplex network.
Half-Duplex Network (512-Bit Rule)
In a half-duplex network, the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain. (A collision domain is the longest path between any two terminal devices, e.g. a terminal, switch, or router.)
The 512-Bit Rule determines the maximum length of cable permitted by calculating the round-trip delay in bit-times (BT) of a particular collision domain. If the result is less than or equal to 512 BT, the path is good.
For more information on the 512-Bit Rule, see the white paper titled “Collision
Domains” on the Transition Networks website at:
http://www.transition.com/learning/whitepapers/colldom_wp.htm
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
7
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate: <10-9 Singlemode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
E-100BTX-FX-05(100) 1310 nm (TX) / 1550 nm (RX) simplex Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
E-100BTX-FX-05(101) 1550 nm (TX) / 1310 nm (RX) simplex Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
E-100BTX-FX-05(102) 1310 nm (TX) / 1550 nm (RX) simplex Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
E-100BTX-FX-05(103) 1550 nm (TX) / 1310 nm (RX) simplex Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
8
E-100BTX-FX-05(10x)
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
Cable Specifications -- Continued
Copper Cable
Category 5:
Gauge: 24 to 22 AWG Attenuation: 22.0 dB /100m @ 100 MHz Maximum Cable Distance: 100 meters
• Straight-Through OR Crossover cable may be used.
• Shielded Twisted-Pair (STP) OR Unshielded Twisted-Pair (UTP) may be used
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1 2
3 6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1 2
3 6
1 2
3 6
1 2
3 6
9
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
Technical Specifications
For use with Transition Networks Model E-100BTX-FX-05(10x) or equivalent
Standards: IEEE 802.3™
Data Rate: 100 Mb/s
Dimensions: 4.7" x 3.0" x 1.0" (119mm x 76mm x 25mm)
Weight: 6 oz. (181 g) (approximate)
MTBF 46,768 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
123,821 hours (Bellcore7 V5.0)
Power Consumption:2.8 Watts, 200 mA
Power Supply: 12 VDC, 0.4 A (minimum) DC Output minimum output regulation: 5%
Connector: 2.1mm barrel, center pin positive
Environment: Tmra*: 0 to 50°C (32 to 122°F)
Storage Temperature: -20 to 85°C (-4 to 185°F) Humidity: 5 to 95%, non condensing Altitude: 0 to 10,000 feet
Warranty: Lifetime
*Manufacturer’s rated ambient temperature.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or View Directly With Optical Instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
Optional Accessories (sold separately)
Part Number Description SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
SPS-1872-CC Optional External Power Supply; 18-72VDC Piggy-back;
Output: 12.6VDC, 1.0 A
E-MCR-03 12-Slot Media Converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
WMBL Optional Wall Mount Brackets
Length: 4.0 in. (102 mm), Fits converter length: 4.7in. (119mm)
WMBV Optional Vertical Mount Bracket; Length: 5.0 in. (127 mm) WMBD Optional DIN Rail Mount Bracket; Length: 5.0 in. (127 mm) WMBD-F Optional DIN Rail Mount Bracket (flat); Length: 3.3in. (84 mm)
10
E-100BTX-FX-05(10x)
Tech Support: 800-260-1312 International: 952-941-7600 7am-6pm CST (GMT-6:00)
Fault Isolation and Correction
If the Media Converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the
Power
LED on the Media Converter illuminated?
NO
• Is the power adapter the proper type of voltage and cycle frequency for the AC outlet?
• Is the power adapter properly installed in the Media Converter and in the outlet?
• Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the SDC LED on the Media Converter illuminated? NO
• Check the twisted-pair cables for proper connection.
• Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 3.
3. Is the SDF LED on the Media Converter illuminated? NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the Media Converter are
connected to the RX and TX ports, respectively, on the other device.
• Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 4.
4. Is the RXC LED on the Media Converter flashing? NO
• If there is no activity on the copper port, proceed to step 5.
• If there is activity on the copper port, disconnect and reconnect the
twisted-pair cable to restart the initialization process.
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 5.
5. Is the RXF LED on the Media Converter flashing? NO
• If there is no activity on the fiber port, contact Tech Support.
• If there is activity on the fiber port, disconnect and reconnect the
fiber cable to restart the initialization process.
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Contact Tech Support: 800-260-1312, Int’l: 00-1-952-941-7600.
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: E-100BTX-FX-05(10x) Series Media Converters Part Number(s): E-100BTX-FX-05(100), E-100BTX-FX-05(101), E-100BTX-FX-05(102),
E-100BTX-FX-05(103)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the
E-100BTX-FX-05(10x)
to which this declaration refers is in
conformity with the following standards.
EN 55022: 19594 Class A; EN 55024:1998; UL 1950, 3rd Edition; 21CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s)
and Standard(s).
_January 16, 2002_____
Stephen Anderson, Vice-President of Engineering Date
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
11
Contact Us
Technical Support
Technical support is avialable 7:00 AM - 6:00 PM CST (GMT -6:00) US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, USA telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Compliance Information
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2002, 2004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks.
Printed in the U.S.A.
33243.C
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Loading...