Transition Networks E-100BTX-FX-04, E-100BTX-FX-04LW, E-100BTX-FX-04MT, E-100BTX-FX-04SC, E-100BTX-FX-04SM User Manual

...
COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 1998-2000 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33057.H
The TRANSITION Networks E-100BTX-FX-04 series Ethernet™ 100BASE-TX to 100BASE-FX media converters connect 100BASE-TX unshielded twisted pair cable to 100BASE-FX multimode OR singlemode fiber-optic cable.
100BASE-TX/100BASE-FX
Media Converters
E-100BTX-FX-04
USER’S GUIDE
E-100BTX-FX-04
Provides an RJ-45 twisted pair 100BASE-TX connector and a set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to 1300 nm multimode fiber-optic cable.
E-100BTX-FX-04(SC)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to 1300 nm multimode fiber-optic cable.
E-100BTX-FX-04(MT)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) MT-RJ 100BASE-FX connector to 1300 nm multimode fiber-optic cable.
E-100BTX-FX-04(SM)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to 1300 nm singlemode fiber-optic cable.
E-100BTX-FX-04(SMLC)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) LC 100BASE-FX connector to 1300 nm singlemode fiber-optic cable.
E-100BTX-FX-04(LH)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to 1300 nm singlemode fiber-optic cable.
E-100BTX-FX-04(XL)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to 1310 nm singlemode fiber-optic cable.
E-100BTX-FX-04(LW)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to 1550 nm singlemode fiber-optic cable.
MDI
MDI-X
E-100BTX-FX-O4
9V DC Input
Config
Switches
1 2 3 4
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
E-100BTX-FX-04 in the Network . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .4
Fault Isolation and Correction . . . . .5
Cable Specifications . . . . . . . . . . . . .6
Technical Specifications . . . . . . . . . .7
Compliance Information . . . . . . . . . .8
E-100BTX-FX-04 IN THE NETWORK
Copper Cable
Category 5 shielded twisted-pair (STP) or unshielded twisted-pair (UTP) copper wire is required. DO NOT USE FLAT OR SILVER SATIN WIRE.
CATEGORY 5:
Gauge 24 to 22 AWG Attenuation 22.0 dB /100m @ 100 MHz Maximum Cable Distance: 100 meters
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3u Case Dimensions 4.75" x 3.0" x 1.0"(119mm x 76mm x 25mm) Shipping Weight 3 pounds (1.4 kilograms) Delay 400nsec round trip Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Power Supply Requirements Replace power supply with only the equivalent input rating (see below) and output rating (regulated 9VDC at 550 mA).
TN PN Requirement Location
3525 240 volts, 50 hertz United Kingdom 3525 230 volts, 50 hertz Europe 3518 120 volts, 60 hertz USA/Canada/Mexico 3514 100 volts, 50-60 hertz Japan 3525 240 volts, 50 hertz Australia
NOTE: This product can be powered by the E-MCR series media converter rack.
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: E-100BTX-FX-04 Series Media Converters Part Number(s): E-100BTX-FX-04, E-100BTX-FX-04(SC), E-100BTX-FX-04(MT),
E-100BTX-FX-04(SM), E-100BTX-FX-04(SMLC), E-100BTX-FX-04(LH), E-100BTX-FX-04(XL), E-100BTX-FX-04(LW)
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the E-100BTX-FX-04 to which this declaration refers is
in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_August 1, 1999_____
Stephen Anderson, Vice-President of Engineering Date
UTP/STP
Fiber
MDI-X switch setting
2 kilometers - multimode 20 kilometers - singlemode 40 kilometers - singlemode (LH)
MDI switch setting
100 meters
100 meters
Switches at the side of the media converter are used to configure the media converter for the network.
MDI/MDI-X SWITCH
Allows straight-through twisted-pair cable to be used for crossover 100BASE-TX connections.
4-POSITION SWITCH 1(UP) Enables Auto-negotiation function to detect and adapt to line
speed/operation mode of attached device. (DOWN) Disables Auto­negotiation function. 2(UP) Allows an attached full-duplex station to transmit and receive simultaneously. (DOWN) Allows an attached half-duplex station to transmit and receive sequentially. 3(UP) Enables BOTH Link Pass Through AND Remote Fault Detect functions. (See page 4) (DOWN) Disables BOTH Link Pass Through AND Remote Fault Detect functions 4 Relevant only if Switch 3 is UP. (UP) Enables Remote Fault Detect function at Switch 3. (DOWN) Disables Remote Fault Detect function at Switch 3.
MDI
1 2 3 4
MDI-X
Do NOT connect media converters between hubs. Install no more than two (2) media converters in series.
The two active pairs in a 100BASE-TX network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
1 2
3 6
Twisted Pair #1
Twisted Pair #2
S
traight Through Cable
1 2
3 6
Loading...
+ 2 hidden pages