Transition Networks E-100BTX-FRL-03(SC) E-100BTX-FRL-03(SM), E-100BTX-FRL-03SM, E-100BTX-FRL-03 User Manual

The TRANSITION Networks Ethernet™ 100BASE-TX to 100BASE-FX media converters connect 100BASE-TX unshielded twisted pair cable to 100BASE-FX multimode OR singlemode fiber-optic cable. Media converter models are selected according to the fiber mode and fiber connector required at the site. Multimode fiber-optic cable can use either an ST connector (E-100BTX-FRL-03) or an SC connector (E-100BTX-FRL-03(SC)). Singlemode fiber (E-100BTX-FRL-03(SM)) uses only an SC connector. All media converters function in half-duplex mode or, when connected to devices capable of full­duplex connectivity, in full-duplex mode. An MDI/MDI-X switch allows straight- through twisted-pair cable to be used for crossover 100BASE-TX connections.
Minneapolis, MN 55344 USA
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class B
FCC Regulations
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Copyright Restrictions
© 1997 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33031.C
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards IEEE 802.3u Case dimensions 4.7" x 3.0" x 1.0" (119mm x 76mm x 25mm)
Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Five years
100BASE-TX/100BASE-FX Media Converters
E-100BTX-FRL-03, E-100BTX-FRL-03(SC), E-100BTX-FRL-03(SM)
USER’S GUIDE
E-100BTX-FRL-03
MDI
MDI-X
E-100BTX-FRL-O3
12V DC Input
UTP
Multimode Fiber
E-100BTX-FRL-03(SC)
MDI
MDI-X
E-100BTX-FRL-O3(SC)
12V DC Input
UTP
Multimode Fiber
E-100BTX-FRL-03(SM)
MDI
MDI-X
E-100BTX-FRL-O3(SM)
12V DC Input
UTP
Singlemode Fiber
Status LEDs on the connector side of the media converters provide the following information:
Power Supply Requirements Replace power supply with only the equivalent input
rating (see below) and output rating (regulated 12VDC @1.5 A).
TN PN
Requirement Location 3507 240 volts, 50 hertz United Kingdom 3342 230 volts, 50 hertz Europe 3340 120 volts, 60 hertz USA/Canada/Mexico 3346 100 volts, 50-60 hertz Japan 3511 240 volts, 50 hertz Australia 3537 (with power cord: 3522) South Africa
NOTE: This product also can be powered by the Transition Networks E-MCR series media converter rack.
E-100BTX-FRL-03
Provides an RJ-45 twisted pair 100BASE-TX connector and a set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to multimode fiber-optic cable.
E-100BTX-FRL-03(SC)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to multimode fiber-optic cable.
E-100BTX-FRL-03(SM)
Provides an RJ-45 twisted pair 100BASE-TX connector and an RX (receive) and TX (transmit) SC 100BASE-FX connector to singlemode fiber-optic cable.
Power Illuminated green LED indicates connection to
external AC power.
SDF Signal Detect/Fiber: Steady green LED
indicates fiber port is connected to device.
SDC Signal Detect/Copper: Steady green LED
indicates RJ-45 port is connected to device.
RXC Receive/Copper: Flashing green LED indicates
packets are seen on RJ-45 port.
RXF Receive/Fiber: Flashing green LED indicates
packets are seen on fiber port.
10BASE-T
SC Connectors
RX
TX
RJ-45 Connector
Fiber
UTP/STP
Power
RXC RXF
SDF SDC
10BASE-T
ST Connectors
RX
TX
RJ-45 Connector
Fiber
UTP/STP
Power
RXC RXF
SDF SDC
Power
RXC RXF
SDF SDC
MDI switch setting
MDI-X switch setting
100 meters
100 meters
2 kilometers - multimode 20 kilometers - singlemode
Straight Through/Crossover Cable Requirements and Pin Specifications
The two active pairs in a 100BASE-TX network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
1 2
3 6
Twisted Pair #1
Twisted Pair #2
Straight Through Cable
1 2
3 6
Straight-through/crossover 100BASE-TX requirements are satisfied using the MDI/MDI-X switch with straight-through cable.
100BASE-TX cable connections between a hub and the media converter require the MDI/MDI-X switch to be set to MDI.
100BASE-TX cable connections between the media converter and a terminal, transceiver or NIC require the switch to be set to MDI-X.
Using small flatblade screwdriver or similar tool and referring to label at front of media converter, set MDI/MDI-X switch position for site installation.
100BASE-TX Cable
1. Is the power LED on the media converter illuminated?
NO
• Is the power adapter the proper type of voltage and cycle frequency for your AC outlet? NOTE: Refer to the “Power Supply Requirements” on the back page.
• Is the power adapter properly installed in the media converter and in the outlet?
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 2.
2. Is the 100BASE-TX Link LED illuminated?
NO
• Check UTP cables for proper connection and pin assignment. (See above.)
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 3.
3. Is the fiber Link LED illuminated?
NO
• Check fiber cables for proper connection.
• Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on the other 100BASE-FX device.
• Refer to Tech Tips available at: http://www.transition.com
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
Troubleshooting the Media Converter
Installation Notes
The physical characteristics of the media cable must meet or exceed IEEE
802.3u 100BASE-TX and 100BASE-FX specifications.
ETHERNET CABLE SPECIFICATIONS
100BASE-FX CABLE SPECIFICATIONS
SINGLEMODE
Fiber-optic Cable Recommended: 9 µm singlemode fiber Fiber-optic Transmitter Power: min: -15.0
dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -8.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 20 kilometers
MULTIMODE
Fiber-optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
100BASE-TX CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
CATEGORY 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Impedance 100 Ω ±10% @ 10 MHz
Maximum Cable Distance: 100 meters (330 feet)
DO NOT CONNECT MEDIA CONVERTERS BETWEEN HUBS.
When connecting to 10Mb/s-100Mb/s device, MANUALLY SET 10Mb/s-100Mb/s SWITCH to 100Mb/s.
KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.
Be certain that the 100BASE-TX MDI/MDI-X switch is set correctly for site installation.
• Connect the power supply cable to the media converter BEFORE connecting to the outlet.
• Install unit with PSU provided. (Output 12 VDC regulated, 350 mA).
• Install no more than two (2) media converters in series.
E-100BTX-FRL-03, E-100BTX-FRL-03(SC), E-100BTX-FRL-03(SM)
toward n
e
Leave in default posi
t