Transition Networks CSRFB1011-100, CSRFB1013-100, CSRFB1014-100, CSRFB1029-100, CSRFB1029-10 User Manual

...
User’s Guide
CSRFB10xx-100
Slide-in-Module Media Converter
Copper to Fiber
10/100 Bridging (2-Port)
10Base-T/100Base-TX to 100Base-FX
The CSRFB10xx-100, 2-port Ethernet/Fast Ethernet bridging media converter is designed to be installed in a Transition Networks PointSystem™ chassis. This converter connects 10Base-T Ethernet or 100Base-TX
Fast Ethernet twisted-pair copper network converters to network converters on a 100Base-FX Fast Ethernet fiber network. The CSRFB includes a status reporting feature for viewing operational parameters only from its remotely attached CSRFB converter via the fiber connection.
Installation . . . . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . . . .7
Cable Specifications . . . . . . . . . . . . .11
Technical Specifications . . . . . . . . . .12
Troubleshooting . . . . . . . . . . . . . . .13
Contact Us . . . . . . . . . . . . . . . . . . .15
Compliance Information . . . . . . . . .16
Part Number Port One - Copper
10Base-T/100Base-TX
Port Two - Duplex Fiber-Optic 100Base-FX
CSRFB1011-100
RJ-45 100 m (328 ft)*
ST, 1310nm multimode 2 km (1.2 miles)*
CSRFB1013-100
RJ-45 100 m (328 ft)*
SC, 1310 nm multimode 2 km (1.2 miles)
CSRFB1014-100
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)
CSRFB1040-100
RJ-45 100 m (328 ft)*
SFP Empty Slot
CSRFB1029-100
RJ-45 100 m (328 ft)*
SC, 1310nmTX/1550nmRX 20km (12.4 miles)
CSRFB1029-101
RJ-45 100 m (328 ft)*
SC, 1550nmTX/1310nmRX 20km (12.4 miles)
CSRFB1029-102
RJ-45 100 m (328 ft)*
SC, 1310nmTX/1550nmRX 40km (24.9 miles)
CSRFB1029-103
RJ-45 100 m (328 ft)*
SC, 1550nmTX/1310nmRX 40km (24.9 miles)
Install CSRFB1029-100/101 and CSRFB1029-102/103 single­fiber optic in the same network where one is the local (center) converter and the other is the remote (terminal) converter.
2
CSRFB10xx-100
24-hour Technical Support: 1-200-260-1312 -- International: 00-1-952-941-7600
Installation
CAUTION: Wear a grounding converter and observe electrostatic discharge precautions while handling the media converter. Failure to observe this caution could result in damage to or failure of the media converter.
The 6-position switch
The 6-position switch is located on the side of the media converter.
Use a small flat blade screwdriver or a similar device to set the recessed switches.
Refer to the drawing to the right for definitions of the individual switch positions.
1. TP Auto-Negotiation up Enables down Disables
2. TP Duplex (Only valid if SW1 is Down) up Full down Half
TP Auto-Negotiate (Up =Enabled, Down Disabled)
TP Duplex (Up=Full, Down=Half)
TP Speed (Up=100Mbs, Down=10Mbs)
Fiber Duplex (Up=Full, Down=Half)
TLPT (Up=Enabled, Down=Disabled)
Center/Terminal (Up=C, Down=T)
123456
UP
Down
Typical system configuration
Remote Terminal Converter
SW6 set to ‘Terminal’
Chassis Center Converter
SW6 set to ‘Center’
Fiber Cable
Chassis
Network
Network
Note: The Loopback test occurs over the fiber connection.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Hardware/software mode jumper
The jumpers are located on the media converter circuit board. Use small needle­nosed pliers or a similar converter to set the jumper.
The Hardware/Software jumper is labeled “H” for hardware and “S” for software.
Hardware The media converter mode is determined
by the settings on the 6-position switch.
Software The media converter mode is determined
by the most recently saved, on-board microprocessor settings.
Note: Software Mode only when the SW6 of the chassis converter is in the UP
position (center).
J6
Hardware/Software
123
H
Pins
S
HS
Installation -- Continued
The 6-position switch--continued
3. TP Speed (Only valid if SW1 is Down)
up 100Mbps down 10Mbps
4. Fiber Duplex
up Forces full duplex operation on the fiber port. down Forces half duplex operation on the fiber port.
5. Transparent Link Pass Through (TLPT) up Enabled down Disabled
6. Center/Terminal Mode (see note) up Center mode (center converter only) down Terminal mode (terminal converter only)
Note: To use the TS1000 compliant Center/Terminal mode function, set SW6 on
the center converter in the chassis to Center Mode, the (UP) position; on the terminal converter at the remote location, set SW6 to Terminal Mode, the (DOWN) position. This allows you to view parameters of the terminal converter from the center converter for monitoring purposes only .
4
CSRFB10xx-100
24-hour Technical Support: 1-200-260-1312 -- International: 00-1-952-941-7600
The Loopback Mode jumper is located on the media converter’s circuit board (labeled ALL= all frames plus errors, Good = Good frames only). See Jumper position to the right.
Loopback test
The loopback test is an automatic test run from the center chassis converter with SW6 set to ‘center,’ the UP position of the switch; and on the terminal converter with SW6 set to ‘terminal,’ the DOWN position of the switch.
Note: This test is self-running after being initiated through software on the center
converter.
The Loopback test does the following:
1. The center converter will put the terminal converter in loopback mode.
2. The center converter sends 100 packets to the terminal converter.
3. The center converter will monitor its receiver for:
a. good packets
b. CRC errors
c. timeouts
4. After the center converter receives all 100 packets back or a time out occurs, it will update its counters and return the terminal converter to its previous mode of operation.
After completing the test, normal operation of the center and terminal converters is established automatically.
J4
Frames
123
Good
Pins
All
All
Good
Installation -- Continued
AutoCross jumper
The AutoCross jumper is located on the media converter’s circuit board (labeled NA = No Autocross; A = AutoCross). See Jumper position below.
Note: Use small needle-nose pliers to set the
jumper.
A Either straight-through or crossover
cable can be used for all twisted-pair copper links.
NA Straight-through or crossover twisted-
pair cable, depending on installed site converters, MUST be installed at EACH twisted-pair copper link.
Note: Factory default is “A” enabled. Transition Networks recommends leaving
the converter in the “A” enabled position.
J7
AutoCross
123
Pins
A
ANA
NA
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Install the slide-in-module
To install the CSRFB10xx-100 media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ chassis.
2. Carefully slide the module into the slot, aligning the module with the installation guides.
3. Ensure that the module is firmly seated inside the chassis.
4. Push in and rotate the panel fastener screw to secure the module to the chassis front.
Media Converter
Panel Fastener
Chassis
Panel Fastener
Mounting Hole