Transition Networks CSETF1011, CSETF1018, CSETF1013 User Manual

COMPLIANCE INFORMATION
UL Listed , C-UL Listed (Canada) CISPR/EN55022 Class A & B CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A & B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A & B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A & B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A & B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A & B. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A & B. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 2000, 2002 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33177.D
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
TRANSITION Networks CSETF10xx series Ethernet™ and Fast Ethernet™ media converters, designed to be installed in a PointSystem™Conversion Center
connect 10BASE-T or 100BASE-TX shielded or unshielded twisted-pair copper cable to 850 nm 10BASE-FL or 850 nm 100BASE-SX multimode fiber-optic cable.
*In the CSETF10xx model designation,10 represents the 10BASE-T/100BASE-TX RJ-45 connector; xx represents the selectable 10BASE-FL/100BASE-SX fiber connector installed on the media converter.
10BASE-T/100BASE-TX to 10BASE-FL/100BASE-SX
Slide-In-Module Media Converters
CSETF10xx
USER’S GUIDE
10BASE-T
INPORT
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPORT
RESET
DB-9
12C
12C-1TERM
INIT
CFMFF100
CFMFF100
10BASE-2
CECF100
CECF100
CFMFF100
CFMFF100
0
50
50
CFMFF100
CFMFF100
CETTF100
Link
Link
Alert
Alert
E
D
CETCF100
CETCF100
CFETF110
CFMFF100
CFMFF100
CFMFF100
CFMFF100
LKS
PWR
PWR
LKM
LKS
LKS
PWR
PWR
LKM
LKM
Multimode
Multimode
Singlemode
Singlemode
TX
TX
RX
RX
TX
TX
RX
RX
LKF
PWR
RXF
RXC
LKC
LA
PWR
PWR
RXF
RXC
LNK
LNK
COL
COL
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
10/100TX
RX
TX
10/100SX
CFETF100
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX 100BASE-FX
Link
Link
Alert
Alert
E
D
0
50
50
Multimode
Singlemode
TX
RX
TX
RX
LA
PWR
PWR
RXF
RXC
LNK
LNK
COL
COL
LKS
LKS
PWR
PWR
LKM
LKM
10BASE-2
10BASE-FL
10BASE-T
LKS
LKS
PWR
PWR
LKM
LKM
LKS
LKS
PWR
PWR
LKM
LKM
Multimode
Multimode
Singlemode
Singlemode
TX
TX
RX
RX
TX
TX
RX
RX
Multimode
Multimode
Singlemode
Singlemode
TX
TX
RX
RX
TX
TX
RX
RX
Multimode
Multimode
Singlemode
Singlemode
TX
TX
RX
RX
TX
TX
RX
RX
10BASE-T
10BASE-FL
Media Conversion Center
Power
In Use
1
Power
In Use
2
CSETF1011
Provides an RJ-45 twisted pair 10BASE-T/100BASE-TX connector and a set of RX (receive) and TX (transmit) ST 10BASE-FL/100BASE- SX connectors to 850 nm multimode fiber-optic cable.
CSETF1013
Provides an RJ-45 twisted pair 10BASE-T/100BASE-TX connector and an RX (receive) and TX (transmit) SC 10BASE-FL/100BASE­SX connector to 850 nm multimode fiber-optic cable.
CSETF1018
Provides an RJ-45 twisted pair 10BASE-T/100BASE-TX connector and an MT-RJ 10BASE-FL/100BASE­SX connector to 850 nm multimode fiber-optic cable.
CSETF10xx in the Network . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .5
Operation . . . . . . . . . . . . . . . . . . . . .6
Fault Isolation and Correction . . . . .8
Cable Specifications . . . . . . . . . . . .10
Technical Specifications . . . . . . . . .11
Compliance Information . . . . . . . . .12
CSETF10xx IN THE NETWORK
The CSETF10xx receives and transmits network signals in either full­duplex or half-duplex mode (depending upon the network devices to which the media converter is attached). Fast Ethernet
in full-duplex mode allows the maximum cable distances shown on these pages. Fast Ethernet
in half-duplex mode requires attention to the 512-bit Rule
(See page 4). NOTE: Both copper and fiber connections to the CSETF10xx must be at
the same media-speed: 10BASE-T AND 10BASE-FL OR 100BASE-TX AND 100BASE-SX – unless one or both network connections is capable of auto-negotiation. The CSETF10xx media converter is designed to work effectively with 10/100 auto-negotiating ports to provide reliable 10 Mb/s or 100 Mb/s fiber links.
Network Configurations
Install two CSETF10xx series media converters in series to extend, over fiber, the distance between two 10BASE-T or two 100BASE-TX devices:
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3,
Compliant with pending TIA/EIA-785 specification
Dimensions 3.4" x 0.86" x 5.0" (86mm x 22mm x 127mm) Weight 8 oz (approximate) Power Consumption 3.6 watts Environment Typical Operating Temperature*: 0-50°C (32°to 122°F )
Storage Temperature: -20 to 85°C Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Lifetime *Operating temperature range for this Slide-In-Module depends on the physical
characteristics and the installation configuration of the TRANSITION Networks chassis in which this Slide-In-Module will be installed. See the User’s Guide for the chassis in which this Slide-In-Module will be installed for a discussion of temperature-related installation constraints.
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CSETF10xx Series Media Converters Part Number(s): CSETF1011, CSETF1013, CSETF1018 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the CSETF10xxto which this declaration refers is in
conformity with the following standards.
EMC-CISPR 22: 1985 Class A&B; EN 55022: 1988 Class A&B; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_April 16, 2000_____
Stephen Anderson, Vice-President of Engineering Date
10BASE-T
INPORT
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPORT
RESET
DB-9
12C
12C-1TERM
INIT
CETTF100
CFETF110
LKF
PWR
RXF
RXC
LKC
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
10/100TX
RX
TX
10/100SX
CFETF100
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX 100BASE-FX
10BASE-T
10BASE-FL
Media Conversion Center
Power
In Use
1
Power
In Use
2
PWR
LKC
SPD
FRX
CRX
10/100TX
RX
TX
10/100SX
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX 100BASE-FX
10BASE-T
INPORT
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPORT
RESET
DB-9
12C
12C-1TERM
INIT
CETTF100
CFETF110
LKF
PWR
RXF
RXC
LKC
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX
10/100TX
RX
TX
10/100SX
CFETF100
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX 100BASE-FX
10BASE-T
10BASE-FL
Media Conversion Center
Power
In Use
1
Power
In Use
2
PWR
LKC
SPD
FRX
CRX
10/100TX
RX
TX
10/100SX
SPD
PWR
FRX
CRX
FLNK
CLNK
RX
TX 100BASE-FX
Loading...
+ 4 hidden pages