Transition Networks CBFTF1011-155, CBFTF1013-155, CBFTF1014-155, CBFTF1015-155, CBFTF1018-155 User Manual

...
* Typical maximum cable distance. Actual distance is dependent upon the physical
characteristics of the network. (TX) = transmit (RX) = receive
** CBFTF1029-155 and CBFTF1029-156
are intended to be installed in the same
network where one is the local converter and the other is the remote converter.
*** CBFTF1029-157 and CBFTF1029-158
are intended to be installed in the same network where one is the local converter and the other is the remote converter.
User’s Guide
CBFTF10xx-15x
Slide-in-Module Media Converter
Copper to Fiber
10/100 Bridging (2-Port)
10Base-T/100Base-TX to 100Base-FX
The CBFTF10xx-15x 2-port Ethernet/Fast Ethernet bridging media converter is designed to be installed in a Transition Networks PointSystem™ chassis and connects 10Base-T Ethernet or 100Base-TX Fast Ethernet twisted-pair copper network devices to network devices on a 100Base-FX Fast Ethernet fiber network.
CBFTF1029-155** RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX) single mode, 20 km (12.4 miles)*
CBFTF1029-156** RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX) single mode, 20 km (12.4 miles)*
CBFTF1029-157*** RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX) single mode, 40 km (24.8 miles)*
CBFTF1029-158*** RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX) single mode, 40 km (24.8 miles)*
Part Number Port One - Copper
10Base-T/100Base-TX
Port Two - Duplex Fiber-Optic 100Base-FX
CBFTF1011-155 RJ-45
100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
CBFTF1013-155 RJ-45
100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
CBFTF1014-155 RJ-45
100 m (328 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)*
CBFTF1015-155 RJ-45
100 m (328 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)*
CBFTF1018-155 RJ-45
100 m (328 ft)*
MT-RJ, 1300 nm multimode 2 km (1.2 miles)*
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .5
Cable Specifications . . . . . . . . . . .8
Technical Specifications . . . . . . . .9
Troubleshooting . . . . . . . . . . . . .10
Compliance Information . . . . . . .12
2
CBFTF10xx-15x
24-hour Technical Support: 1-200-260-1312 -- International: 00-1-952-941-7600
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the 4-position switch, removing and inserting circuit board jumper(s), and installing the slide-in-module. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
Set the 4-Position Switch
The 4-position switch is located on the side of the media converter.
Use a small flat blade screwdriver or a similar device to set the recessed switches.
Refer to the drawing to the right for the locations of the individual switches.
1. Auto-Negotiation up Enables Auto-Negotiation on the copper port.
Advertises 100 Mb/s full duplex and half duplex, and 10 Mb/s full duplex and half duplex.
down Disables Auto-Negotiation on the copper port.
2. Copper Mode
(Applies only if switch 1 is down.)
up Forces full duplex operation on the copper port. down Forces half duplex operation on the copper port.
(Parallel detection only with Auto-Negotiation enabled)
up Parallel detects in IEEE standard half duplex
down Non-standard full duplex
3. Speed
(Applies only if switch 1 is down.)
up Forces 100 Mb/s operation on the copper port. down Forces 10 Mb/s operation on the copper port.
4. Fiber Mode up Forces full duplex operation on the fiber port. down Forces half duplex operation on the fiber port.
Speed (up=100Mb/s)
Copper Mode (up=Full-Duplex)
Auto-Negotiation (up=Enabled)
Fiber Mode (up=Full-Duplex)
1234
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation -- Continued
Set the Jumpers
The jumpers are located on the media converter circuit board. Use small needle­nosed pliers or a similar device to set the jumper.
The Hardware/Software jumper is labeled “H” for hardware and “S” for software.
Hardware The media converter mode is determined by the
4-position switch settings listed above.
Software The media converter mode is determined by the
most-recently saved, on-board microprocessor settings.
The Far-End Fault jumper is labeled “E” for enable Far-End Fault and “D” for disable Far-End Fault.
Enable A fault on the fiber link causes the media
converter to transmit a Far-End Fault signal.
Disable No Far-End Fault signal is transmitted when a
fault occurs.
Software Mode
Hardware Mode
H J2 S
H J2 S
Disable Far-End Faul
t
Enable Far-End Fault
E J1 D
E J1 D
Install the Slide-in-Module
To install the CBFTF10xx-15x media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ chassis.
2. Carefully slide the module into the installation slot, aligning the module with the installation guides.
3. Ensure that the module is firmly seated inside the chassis.
4. Push in and rotate the panel fastener screw to secure the module to the chassis front.
Power the Media Converter
The CBFTF10xx-15x module media converter is powered through the PointSystem™ chassis.
CFMFF100
10BASE-2
CECF100
CFMFF100
0
50½
Link Alert
E
D
CETCF100
CFETF100
CFETF110
CFMFF100
LA
PWR
RXF
RXC
LNK
COL
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
100BASE-TX
RX
TX
100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
LKS
PWR
LKM
10BASE-2
10BASE-FL
10BASE-T
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R E S E T
I
0
Panel Fastener Screw
4
CBFTF10xx-15x
24-hour Technical Support: 1-200-260-1312 -- International: 00-1-952-941-7600
Installation -- Continued
Install the Twisted-Pair Copper Cable
1. Locate or build IEEE 803.2compliant 10Base-T or 100Base-TX cables, with straight-through RJ-45 cable, and with straight-through RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port connector on the media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port connector on the other device (switch, workstation, etc.).
NOTE: The MDI (straight-through) or MDI-X (crossover) cable connection is configured automatically, according to the network conditions.
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port
on the media
converter
Install the Fiber Cable
1. Locate or build IEEE 803.2compliant 100Base-FX fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the CBFTF10xx-15x media converter as described:
Connect the male TX cable connector to the female TX connector.
Connect the male RX cable connector to the female RX connector.
3. Connect the fiber cables to the other device (media converter, hub, etc.) as described:
Connect the male TX cable connector to the female RX connector.
Connect the male RX cable connector to the female TX connector.
Connect the fiber cable to the media converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Operation
Status LEDs
Use the status LEDs to monitor the media converter and the network connections.
FDPX (Fiber Duplex)
On = full duplex fiber connection.
Off = half duplex fiber connection.
FLNK (Fiber Link)
On = Fiber link connection.
Blinking = Fiber network activity.
PWR (Power)
On = Chassis power.
TSPD (Twisted-Pair Speed)
On = 100 Mb/s.
Off = 10 Mb/s.
TDPX (Twisted Pair Duplex)
On = full duplex copper connection.
Off = half duplex copper connection.
TLKN (Twisted Pair Link)
On = Copper link connection.
Blinking = Copper network activity.
CBFTF155
PWRFDPX FLNK
TLNKTSPD TDPX
RX
TX
100Base-FX
10/100Base-TX
Loading...