Installation
CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when setting the 4-position switch, removing and inserting circuit board jumper(s), and
installing the slide-in-module. Failure to observe this caution could result in damage
to, and subsequent failure of, the media converter.
Set the 4-Position Switch
• The 4-position switch is located on
the side of the media converter.
• Use a small flat blade screwdriver
or a similar device to set the
recessed switches.
• Refer to the drawing to the right
for the locations of the individual
switches.
1. Auto-Negotiation
up Enables Auto-Negotiation on the copper port.
Advertises 100 Mb/s full duplex and half duplex,
and 10 Mb/s full duplex and half duplex.
down Disables Auto-Negotiation on the copper port.
2. Copper Mode
(Applies only if switch 1 is down.)
up Forces full duplex operation on the copper port.
down Forces half duplex operation on the copper port.
(Parallel detection only with Auto-Negotiation enabled)
up Parallel detects in IEEE standard half duplex
down Non-standard full duplex
3. Speed
(Applies only if switch 1 is down.)
up Forces 100 Mb/s operation on the copper port.
down Forces 10 Mb/s operation on the copper port.
4. Fiber Mode
up Forces full duplex operation on the fiber port.
down Forces half duplex operation on the fiber port.
Speed (up=100Mb/s)
Copper Mode (up=Full-Duplex)
Auto-Negotiation (up=Enabled)
Fiber Mode
(up=Full-Duplex)
1234
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation -- Continued
Set the Jumpers
The jumpers are located on the media converter circuit board. Use small needlenosed pliers or a similar device to set the jumper.
The Hardware/Software jumper is labeled “H” for hardware
and “S” for software.
Hardware The media converter mode is determined by the
4-position switch settings listed above.
Software The media converter mode is determined by the
most-recently saved, on-board microprocessor
settings.
The Far-End Fault jumper is labeled “E” for enable Far-End
Fault and “D” for disable Far-End Fault.
Enable A fault on the fiber link causes the media
converter to transmit a Far-End Fault signal.
Disable No Far-End Fault signal is transmitted when a
fault occurs.
Software Mode
Hardware Mode
H J2 S
H J2 S
Disable Far-End Faul
Enable Far-End Fault
E J1 D
E J1 D
Install the Slide-in-Module
To install the CBFTF10xx-15x media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ chassis.
2. Carefully slide the module into the installation slot, aligning the module with
the installation guides.
3. Ensure that the module is firmly seated inside the chassis.
4. Push in and rotate the panel fastener screw to secure the module to the chassis
front.
Power the Media Converter
The CBFTF10xx-15x module media converter is powered through the
PointSystem™ chassis.
CFMFF100
10BASE-2
CECF100
CFMFF100
0
50½
Link Alert
E
D
CETCF100
CFETF100
CFETF110
CFMFF100
LA
PWR
RXF
RXC
LNK
COL
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
100BASE-TX
RX
TX
100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
LKS
PWR
LKM
10BASE-2
10BASE-FL
10BASE-T
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R
E
S
E
T
I
0
Panel Fastener Screw