Trane 4TTX6060E, 4TTX6048, 060E, 4TTX6036 User Manual

Split System Cooling Product Data
XL16i
4TTX6024, 036, 048 & 060E
2, 3, 4 & 5 Tons
PUB. NO. 22-1752-10
CLIMATUFF™ 2-stage scroll
compressor
Efficiency up to 18.50 SEER
All Aluminum SPINE FIN™ coil
WEATHERGUARD™ II top shields
unit
DURATUFF™ weather proof and
rust proof base
COMFORT ”R”™ mode approved
for better comfort indoors
QUICK-SESS™ cabinet,
service access and refrigerant connections with full coil protection
WEATHERGUARD™ fasteners
Glossy corrosion resistant finish
tarpaulin gray cabinet with anthracite gray top
Internal compressor high/low
pressure & temperature protection
Liquid line filter/drier
Low sound with advanced variable
speed fan motor
Service valve cover
R-410A refrigerant
From 70 to 100% capacity
modulation
100% run test in the factory
Low ambient cooling to 55° as
shipped
Extended warranties available
© 2010 Trane 2 22-1752-10
Contents
Features and Benefits 2
General Data 4
Product Specifications 4 A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5
Model Nomenclature 6
Electrical Data 7
Dimensions 8
Mechanical Specifications 9
22-1752-10 3
General
A-weighted Sound Power Level [dB(A)]
A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]
63 125 250 500 1000 2000 4000 8000
4TTX6024E 72 43.7 52.6 54.3 62.4 60.4 57 54.1 46.6
4TTX6036E 72 38 50.4 56.8 60.4 59.8 57.2 55.2 49.2
4TTX6048E 73 44.2 50.4 58.9 63.1 63 57.4 53.6 47.4
4TTX6060E 74 42.2 53.8 57.8 66 65.7 57.7 58.4 51.7
Note: Rated in accordance with AHRI Standard 270-2008.
SOUND POWER
LEVEL [dB(A)]
MODEL
Data
Product Specifications
Model No. 1 4TTX6024E1 4TTX6036E1 4TTX6048E1 4TTX6060E1
Electrical Data V/Ph/Hz 2 230/1/60 230/1/60 230/1/60 230/1/60 Min Cir Ampacity 14 22 29 39 Max Fuse Size (Amps) 20 35 50 60
Compressor CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL RL AMPS - LR AMPS 10.3 - 52 16.7 - 82 21.2 - 104 28.8 - 152.9 Outdoor Fan FL Amps 0.74 0.74 2.80 2.80 Fan HP 1/8 1/8 1/3 1/3 Fan Dia (inches) 27.6 27.6 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 9/13-LB/OZ 9/13-LB/OZ 12/9-LB/OZ 12/9-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 3/4 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 Weight - Shipping 309 316 328 332 Weight - Net 261 266 291 295
Start Components NO NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat NO NO NO NO
Optional Accessories: 4
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 BAYKSKT260 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 Extreme Condition Mounting Kit BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004
Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001
Refrigerant Lineset 5 TAYREFLN9* TAYREFLN7* TAYREFLN3* TAYREFLN4*
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)
4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
4 22-1752-10
General Data
Accessory Description and Usage
Rubber Isolators — 5 rubber donuts to isolate condens-
ing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized.
Extreme Conditions Mounting Kit — Bracket kits to secure­ly mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc.
Low Ambient Cooling — For low ambient cooling below 55° see Application Guide APP-APG013-EN.
AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling opera­tion.) Standard Noise Rating number is at 95°F outdoor air.
22-1752-10 5
Model
Refrigerant Type
4 = R-410A
TRANE
Product Type
W = Split Heat Pump T = Split Cooling
Product Family
Z = Leadership – Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial
Family SEER
3 = 13 6 = 16 0 = 20 4 = 14 8 = 18 5 = 15 9 = 19
Split System Connections 1-6 Tons
0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier
Outdoor Units
4TTX6036E1000AA
Refrigerant Type
4 = R-410A
Application
TE = Fully Convertible TG = Semi Convertible TF = Front Return
Product Family
E = Leadership – Variable Speed P = Leadership C = Replacement/Retail B = Basic
Flow Control
0 = No Flow Control 3 = Nonbleed TXV
Feature Identifier
0 = Standard Unit F = Air-Tite™
Nominal Capacity in 1000’s (BTUH)
Major Design Change
Power Supply
1 = Single Phase
Electrical Connection
0 = Pig Tails B = Circuit Breaker D = Pull Disconnect
Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
Unit Parts Identifier
NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years.
Air Handlers – Residential
4TEE3F36A1 AA000
Gas Furnaces
TU D2B080AC AAV32
4TXCB001 C C3 H CAA
Refrigerant Type
4 - R410A
Product Family
T-Premium (Heat Pump or Convertible Coil)
Coil Design
X - Direct Expansion Evaporator Coil
Product Family
C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil
Coil Width (Cased/Uncased)
A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5"
Refrigerant Line Coupling
0 - Brazed
Model Number Distinguisher
Major Design Change
Efficiency
C - Standard S - Hi Efficiency (Derived from 10 SEER products)
Refrigerant Control
3 - TXV - Non-Bleed
Coil Circuitry
H - Heat Pump
Airflow Configuration
A - Upflow Only U - Upflow / Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow
Minor Design Change
Unit Parts Identifier
Coils – Residential
Nomenclature
6 22-1752-10
Electrical Data
Schematic Diagrams
(SEE LEGEND)
4TTX6024E, 036E
22-1752-10 7
Printed from D156630P02 Rev 00
Electrical Data
Schematic Diagrams
(SEE LEGEND)
4TTX6048E, 060E
8 22-1752-10
Electrical Data
Schematic Diagrams
LEGEND
22-1752-10 9
Dimensions
4TTX6 Outline Drawing
Note: All dimensions are in MM (Inches).
MODELS BASE A B C D E F G H J K
4TTX6024E 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 5/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)
4TTX6036E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 1035 (40-3/4)
4TTX6048E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)
4TTX6060E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)
From Dwg. D152635 Rev. 16
10 22-1752-10
Mechanical Specifications
General
The 4TTX6 is fully charged from the fac­tory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient tempera­tures as high as 115°F. Cooling capaci­ties are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit shall be certi­fied to UL 1995. Exterior is designed for outdoor application.
Casing
Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Cor­rosion and weatherproof CMBP-G30 DuraTuff™ base.
Refrigerant Controls
Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.
Compressor
The Climatuff® 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and modular plugs for electrical connections.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.
Low Ambient Cooling
As manufactured, this unit has a cool­ing capability to 55°F. For low ambient cooling below 55° see Application Guide APP-APG013-EN.
22-1752-10 11
Trane www.trane.com
Trane has a policy of continuous product and product data improvement and it reserves the right to change
design and specifications without notice.
10/10
Loading...