TRACO THI0513, THI0511, THI0512, THI2411, THI1222 Datasheet

...
Features
I/O-Isolation Test Voltage 6000V Supplementar y Insulation to meet IEC/EN
60950 and IEC/EN 60601-1 Safety Standards Agency Safety Approvals SMD-Technology with Ceramic Capacitors Regulated Single– and Dual Output Models Low Coupling Capacity 24–Pin DIP Plastic Package 2 Year Product Warranty
DC/DC Converter
THI Series 2 Watt
The THI series is a family of dc/dc-converter with very high I/O­Isolation specification. They are certified according to EN 60950 and IEC-60601-1 safety standards and offer a cost effective so­lution for all industrial, telecom and medical applications where a supplementary insulation is required. SMD-technology and a 100 % production test of the safety barrier ensure a very high reliability of this product.
Models
Ordercode Input voltage Output voltage Output current max. Efficiency typ.
THI 0511 5 VDC 400 mA 62 % THI 0512 12 VDC 165 mA 63 % THI 0513 THI 0520 ± 5 VDC ±100 mA 42 % THI 0521 ±12 VDC ± 80mA 57 % THI 0522 ±15 VDC ± 65mA 57 %
THI 1211 5 VDC 400m A 62 % THI 1212 12 VDC 165mA 63 % THI 1213 THI 1220 ± 5 VDC ±100 mA 45 % THI 1221 ±12 VDC ± 80mA 59 % THI 1222 ±15 VDC ± 65mA 59 %
5 VDC ± 10%
12 VDC ± 10%
15 VDC 130mA 64 %
15 VDC 130mA 64 %
THI 2411 5 VDC 400m A 62 % THI 2412 12 VDC 165mA 63 % THI 2413 THI 2420 ± 5 VDC ±100 mA 45 % THI 2421 ±12 VDC ± 80 mA 58 % THI 2422 ±15 VDC ± 65 mA 58 %
24 VDC ± 10%
15 VDC 130mA 64 %
www.tracopower.com Page 1
Input Specifications
Input current no load 5 Vin models: 100 mA typ.
12 Vin models: 50 mA typ. 24 Vin models: 30 mA typ.
Input current no load 5 Vin models: 660 mA typ.
12 Vin models: 280 mA typ. 24 Vin models: 140 mA typ.
Surge voltage (1 sec. max.) 5 Vin models: 7.5 V max.
12 Vin models: 15 V max. 24 Vin models: 30 V max.
Input filter Pi-Filter
Output Specifications
Voltage set accuracy ± 3 % Voltage balance (dual output models) ± 3 % max.
DC/DC Conver ter
THI Series 2 Watt
Regulation – Input variation Vin min. to Vin max. ± 0.5 % max.
– Load variation 10 – 100 %: ± 1.0 % max.
Ripple and noise (20 MHz Bandwidth) 50 mVpk-pk max.
Temperature coefficient ± 0.02 % / °C Current limitation > 120 % constant current Short circuit protection indefinite (automatic recovery) Capacitive load – Single output models 680 µF max.
– Dual output models 270 µF max.
Isolation /Safety
Isolation voltage – Rated isolation voltage 3’000 Vrms (for 250VAC working voltage)
– Isolation test voltage (1 sec.) 6‘000 VDC
Isolation capacity Input/Output 20 pF typ.
Isolation resistance Input/Output >10‘000 M ohm
Safety standards EN 60950
IEC/EN 60601-1 rated for 250VAC
Safety approvals test report by BSI (British Standard Institute)
General Specifications
Temperature ranges – Operating –25 °C ... +60 °C
– Case + 95 °C – Storage – 40 °C ... +125 °C
Derating above 60°C 3%
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 E) > 600’000 h @ 25 °C Switching frequency 25 – 80 kHz (depending on load)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.