SPECIFICATIONS
Range: –58 to 572°F / –50 to 300°C
Resolution: 0.1° (–19.9 to 199.9)
1° (otherwise)
OPERATION
Remove the stainless steel probe from the
protective sheath. Press the ON/OFF button to
turn the unit on. Press the °F/°C button to switch
between Fahrenheit and Celsius temperature.
Insert the probe into the material to be measured
and read the display.
To conserve battery life, always turn the unit off
when it is not in use. To turn the unit off, press the
ON/OFF button.
MAX/MIN MEMORY
To view the minimum and maximum temperature
reached since turning the unit on, press the
MAX/MIN button. “MIN” appears on the display
to indicate the minimum temperature recorded.
Press the MAX/MIN button a second time within
3 seconds to view the maximum temperature.
“MAX” appears on the display to indicate the
maximum temperature recorded.
Three seconds after pressing the MAX/MIN button,
the display automatically returns to the current
temperature (“MIN” or “MAX” no longer appears on
the display). Once the unit is turned off, the MIN
and MAX temperatures are cleared.
HOLDER
The metal holder allows the probe to be positioned
at any height while attached to beakers, stainless
steel cylinders, vats, etc.. Pinch the ends of the
holder and place the stem of the thermometer into
one of the 3 holes in the top portion of the holder
and then through the bottom of the holder. The
different holes allow the stem to be held at different
angles. When the ends of the holder are released,
the holder will expand to grab the stem of the
thermometer securely. Use the clip to attach the
holder to the side wall of a container. To remove
the holder, pinch the ends of the holder and
remove the stem of the thermometer.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com

ALL OPERATIONAL DIFFICULTIES
If this thermometer does not function properly
for any reason, replace the battery with a new
high quality battery (see “Battery Replacement”
section). Low battery power can occasionally
cause any number of “apparent” operational
difficulties. Replacing the battery with a new
fresh battery will solve most difficulties.
BATTERY REPLACEMENT
Erratic readings, faint readings, or no display
are all indications that the battery must be
replaced. Open the battery cover by turning it
1/4 of a turn in the direction of the OPEN arrow
(counter-clockwise). (Be careful not to turn the
cover more than 1/4 of a turn as this may damage the battery cover.) Remove the exhausted
battery and replace with a new battery. Equivalent
battery replacements are: Ray-O-Vac RW42,
Duracell D357, and Everready 357. Make certain
the positive (+) side is facing out. Replace the
battery cover by lining up the tabs and turning the
cover approximately 1/4 of a turn clockwise until
the cover locks into place. (Be careful not to turn
the cover after is has locked into place as this may
damage the battery cover.)