TP-Link ecoNET300 Operation And Installation Manual

Page 1
OPERATION AND INSTALLATION MANUAL
ISSUE: 1.1 APPLIES TO THE REGULATOR:
boiler, series: ecoMAX800 (excluding ecoMAX800R1,T1), ecoMAX850, ecoMAX860, ecoMAX910/920
solar: ecoSOL301/400
heat pump, series: ecoTRONIC100/200
ventilation, seria: ecoVENT
INTERNET MODULE
ecoNET300
REMOTE CONTROL OF REGULATORS
09-2017
www.econet24.com
ecoNET.apk
ecoNET.app
Page 2
Page 3
CONTENS OF TABLE
1. INFORMATION ABOUT DOCUMENTATION ......... 4
2. APPLIED SYMBOLS .............................................. 4
4. DYREKTYWA WEEE 2012/19/UE ................................. 4
3. INFORMATIONS .................................................. 5
4. SAFETY ................................................................ 5
5. COOPERATION WITH REGULATORS .................... 6
6. CONNECTION TO THE REGULATOR ..................... 6
6.1 CONNECTION WITH ECOMAX800 SERIES ................. 6
6.2 CONNECTION WITH ECOMAX850 SERIES ................. 6
6.3 CONNECTION WITH ECOMAX860 SERIES ................. 7
6.4 CONNECTION WITH ECOMAX910/920 SERIES .......... 8
6.5 CONNECTION WITH ECOSOL .................................. 8
6.6 CONNECTION WITH ECOTRONIC SERIES ................... 8
6.7 CONNECTION WITH ECOVENT SERIES ...................... 9
7. CONNECTION WITH INTERNET ........................... 9
8. LOGGING TO THE MODULE FROM THE LOCAL LAN 11
9. LOGGING TO ECONET ACCOUNT ...................... 11
9.1 FIRST LOGGING TO ECONET ACCOUNT ................... 11
10. WEBSITE SUPPORT ............................................ 12
10.1 CURRENT DATA .................................................. 13
10.2 DIAGRAM ......................................................... 13
10.3 USER AND SERVICE PARAMETERS ........................... 13
10.4 HEAT YIELD GRAPH ............................................. 13
10.5 DATA HISTORY ................................................... 13
10.6 ALARMS ........................................................... 14
10.7 SCHEDULE ........................................................ 14
10.8 FUEL CONSUMPTION........................................... 15
10.9 DEVICE SETTINGS ............................................... 15
11. MOBILE APPLICATION ....................................... 15
12. RESTORING DEFAULT USER NAME AND
PASSWORD ................................................................... 16
Page 4
4

1. Information about documentation

The manual is a supplement for the regulator manual. In particular, except for this manual, the regulator manual should also be observed. We are not responsible for any damages caused by failure to observe these instructions.

2. Applied symbols

In this manual the following graphic symbols are used:
- the sign means that the posted information has an impact on safety,
- the sign indicates that the
information provided relates to the features of the module.

4. Dyrektywa WEEE 2012/19/UE

Purchased product is designed and made of materials of highest quality. The product meets the requirements of the
Directive 2012/19/EU of 4 July 2012 on waste electrical and electronic equipment (WEEE), according to which it is
marked by the symbol of crossed-out wheeled bin (like below), meaning that product is subjected to separate collection.
Responsibilities after finishing a period of using product:
dispose of the packaging and product at
the end of their period of use in an appropriate recycling facility,
do not dispose of the product with other
unsorted waste,
do not burn the product.
By adhering obligations of waste electrical and electronic equipment controlled disposal mentioned above, you avoid harmful effects on the environment and human health.
Page 5
5

3. Informations

The internet module enables regulator operation remote control (on-line) via Internet or a (LAN/Wi-Fi) local network. User can remotely monitor operation of the regulator and modify operation parameters of the regulator controller with the use of a computer, a tablet or mobile phone. Essential features of the module:
the ecoNET300 integrated WWW server
enabling remote control of operation of the regulator within a local network without Internet access,
cooperation with www.econet24.com
external server provides access to regulator via Internet,
supports Wi-Fi wireless networks,
preview of current operation parameters
of the regulator in readable and clear “tiles”,
visualization via readable hydraulic
diagram indicating current operation of the hydraulic system,
preview and edition options of most (user
and service) parameters of the regulator,
registration of operation parameters and
alarm conditions of the regulator,
possibility of e-mail notifications
concerning alarm conditions of the regulator.

4. Safety

In any circumstances do not modify construction of the device.
Device can be started and connected only by a person who read this manual.
Connecting the internet module not in accordance with the manual or improperly can result in inappropriate operation of the controller or interruption of its operation.
Verify if regulator software is adapted to cooperate with ecoNET300 internet module.
Do not use the device for other than intended use.
Always turn off the regulator before connecting the internet module.
Page 6
6

5. Cooperation with regulators

Check regulator software version before connecting a ecoNET300 module with the regulator. In the regulator main menu select tab: MENU Information Software version User can contact with the regulator manufacture in order to verify whether a particular type of regulator will be cooperating with ecoNET300 according to data concerning regulator software versions.

6. Connection to the regulator

The ecoNET300 internet module has to be connected with regulator with the use of ecoLINK2 interface. In case of some types of regulators it is necessary to use an appropriate adapter. The ecoLINK2 interface and adapter are a part of the ecoNET300 set.
Adapter: 1 - socket for RJ11 ecoLINK2 interface, 2
- a plug for regulator module transmission socket, 3 - socket for a control panel plug.
6.1 Connection with ecoMAX800
series
This chapter applies to ecoMAX800 P1, P2, R2, T2, D1, D2 regulators. It is not applicable to ecoMAX800R1 and ecoMAX800T1. In case of ecoMAX800 series, a EL2adapter or El2adapter v2 must be used in order to connect ecoLINK2.
6.2 Connection with ecoMAX850
series
The ecoMAX850P1 or ecoMAX850D1 regulator modules are equipped with an additional COM transmission socket to connect RJ11 plug of ecoLINK2 interface without using any adapters. Just unscrew the regulator housing and put the plug into a COM socket.
In order to connect the ecoNET300 module with the regulator, ecoLINK2 interface is required which is a part of the set.
The internet module will cooperate only with regulators with installed software supporting ecoNET300 module.
Page 7
7
Connection with ecoMAX850P1, D1: 1 – COM socket (place of plugging a RJ11 interface plug), 2 – a socket with connected plug of the control panel, 3 –regulator housing cover (possible place where a control panel can be assembled).
Modules of ecoMAX850P2 controllers are equipped with just one COM transmission socket in RJ11 standard which a control panel (located inside or outside the controller housing) is connected to. Using one RJ11 socket in the module requires connecting an additional divider (telephone RJ11 tee separator) and additional cable.
Standard divider, RJ11 telephone divider: 1­connection of RJ11 ecoLINK2 interface plug, 2­connection of the control panel plug, 3­connection of an additional cable with two RJ11 terminals.
Standard RJ11 telephone cable with an option of connecting wires and a method of connecting into the divider.
Below show location of the regulator COM transmission socket, where: interface ecoLINK2,on diagram includes: COM transmission socket (connection point between cable and divider), divider, control panel, additional ecoSTER TOUCH control panel (in ecoMAX850I version) and ecoSTER200, additional cable to a divider.
6.3 Connection with ecoMAX860
series
In case of ecoMAX860P1, P2, P3 series, a El2adapter v2 must be used in order to connect ecoLINK2 interface. P1 version:
P2 version:
Page 8
8
P3 version:
6.4 Connection with ecoMAX910/920
series
In case of ecoMAX910, 920 series, the ecoLINK2 interface must be connected directly to the regulator's RJ11 socket.

6.5 Connection with ecoSOL

In case of ecoSOL301, 400, 500 series, the ecoLINK2 interface must be connected directly to the regulator's RJ11 socket.
6.6 Connection with ecoTRONIC
series
In case of ecoTRONIC100, 200 series, a El2adapter v2 must be used in order to connect ecoLINK2 interface.
Page 9
9

6.7 Connection with ecoVENT series

The Internet module must be connected to the regulator module via the ecoLINK2 interface, without the RJ11 plug (according to the interface label). Connect the conductors of the interface cable to the regulator terminals together with the conductors of the control panel cable.
OEM version:
MAXI version:

7. Connection with Internet

Connect adapter plug to a mini USB Port socket and 3G USB Port to the ecoLINK2 interface. Connect with RJ45 Ethernet Port with Ethernet cable, e.g. with ADSL router, switch and modem. A socket does not have to be use in case of Wi-Fi wireless network access. The Mode Switch can be set in any position.
Connection of ecoNET300 with ETHERNET RJ45 with access points of LAN wire Internet network or
with Wi-Fi wireless network.
The ecoNET300 requires constant access to a wire LAN or wireless Wi-Fi network in a place of installation of the regulator.
mini USB Port
3G USB Port
RJ45 Ethernet Port
Mode Switch
Page 10
10
LED
LED
condition
Module operation
condition
Power
ON
Power on.
OFF
Power off.
Connection
with a
regulator
ON
Active connection of the regulator.
OFF
No connection with regulator.
Connection
with WiFi
ON
Connection to a programmed wireless network is on.
OFF
No connection with wireless network.
Connection
with a server
ON
Connection with www.econet24.com external server is on.
OFF
No connection for www.econet24.com external server.
After the power is on, ecoNET300 requires app. 1 minute in order to load the operational system. Then, the module begins to work and indicates its condition with LED indicators. In a connection between ecoNET300 module with a regulator is active,
a “ connection with controller” indicator
lights up. New functions for managing ecoNET300 module are added to the main menu.
MENU Information ecoNET WiFi MENU Information ecoNET Ethernet MENU Main settings WiFi
In case of connection with LAN wire network, a ecoNET Ethernet tab will be available in regulator menu from which the IP number, mask and gate can be read out and ecoNET24 server connection condition can be checked. It is required to save the displayed IP number (e.g. IP:10.1.2.237). This number in a form of: http://10.1.2.237 is entered into the address field from the level of LAN network. A website to operate the regulator menu will be activated.
It is necessary to enter network parameters in General settings menu of the control panel in order to make a wireless connection via Wi-Fi. To do this, select:
MENU general settings WiFi (WiFi settings)
Select SSID in Network Settings. It is a name of the local wireless network which has to be the same for all devices working in this network (SSID can be, e.g.: myWiFi).
In case of connection with a chosen Access Point via wireless network, user has to know the settings of Wi-Fi network which the module will be connected to: network name (SSID), protection type, access password.
The ecoNET300 requires active DHCP server of Access Point (e.g. router) because manual IP assignment for ecoNET300 internet module is not supported. More information can be obtained from router configuration software or network administrator.
WPS/RESET button. Deleting user name and password and restoring default settings. User: admin, password: admin. Works only in local version.
The LED indicators of module operation condition.
Page 11
11
Use the "TOUCH and PLAY" knob to select letters and characters from the list, or touch on the onscreen keyboard. Selected name is confirmed with ENTER/OK.
In Network settings select Security. Select and confirm encryption type in Wi-Fi network (most often selected type is WPA2). Go to Password tab. Enter Wi-Fi access password using letters/characters available on the listand confirm with ENTER/OK. Filling data correctly results in ecoNET300 connected to a Wi-Fi network.
In MENU Information ecoNET WiFi, user can readout an IP number, Mask, gate and ecoNET24 connection condition (required: Server: Connected). IP number is used for opening a boiler controller website from a level of LAN network.
8. Logging to the module from the local
LAN
The WWW server incorporated in ecoNET300 module enables remote management of regulator on LAN local network without any access to the Internet. Enter: http://module IP address in the address field of the internet browser. Where can be read IP out from the regulator menu:
MENU Information ecoNET Ethernet
or ecoNET WiFi. Activated page will ask for user and password. Default settings are: User: admin Password: admin After correct login, a WWW page for managing the regulator operation will be displayed.

9. Logging to ecoNET account

The ecoNET300 internet module cooperates with external server which is available under www.econet24.com This provides access to the regulator via Internet. In order to log into an account on an external server, enter www.econet24.com into an address field of the web browser. Enter login and password in order to log into ecoNET account.
To reminder the password for an existing account, we choose FORGOT PASSWORD and enter your email. A password reminder will be sent to your email account.

9.1 First logging to ecoNET account

In case of first logging, user has to create a new account in REGISTER tab.
In order to guarantee safety by preventing unauthorized persons from direct access to the controller, it is recommended to change default login settings (username password).
The Wi-Fi network parameters (SSID, protection type and password) can be also configured from a level of ecoNET300 website after previously connecting it to a LAN wire network.
myWiFi
OK
CANCEL
SSID settings
myWiFi
Page 12
12
Following conditions must be met:
the regulator has to be connected to a
power supply and properly connected to internet module,
the internet module should be connected
to the Internet and be logged into the external server (“Server connection” indicator is active),
from ecoNET WiFi/Info tab in the
regulator main menu, should be read the UID number (unique ID of the regulator): MENU Information
ecoNET WiFi/Info
The UID number should be entered on the REGISTRATION tab. If the system correctly validates the UID number, the account registration form will be displayed. It should be complete the form with the data of the regulator user and enter the login password. Form field:
UID controller – the regulator's UID is
shown. The ecoNET24 server verifies whether UID number is correct.
Controller label – enter any name of
regulator.
Remote access to the controller by the
service and the producer – enables to
access and edit regulator parameters via the service and the producer.
Controller installation address (Same as
the user's address) – check this field if
the regulator address is the same as residential address.
Alarm notifications (Allows to send alarm
notifications by email) – in case an alert
occurs, an alarm message including alarm contents will be sent on previously
entered e-mail address. Obligatory fields: E-mail, Password, Password (again). Creating an ecoNET account will only be possible after you have read the Terms of Use in the form of regulations. Press the
Register button.

10. Website support

Description of the Web page menu for managing the work of the regulator.
Current data
Current readout of the regulator operation condition data and possibility of changing its selected parameters.
Diagram
Graphical representation of hydraulic diagram of installation with current operation condition readout for its particular elements.
User parameters
Detailed readout and modification of operation parameters of the regulator.
Service parameters
Detailed reading and modification of advanced parameters of the regulator only after entering the service password.
Heat yield graph
Graphic graph of heat yield. NOTE: Bookmark available only for ecoSOL301/400/500 regulators.
Data history
Data archive of selected regulator operation parameters. Alarms
List of regulator alarms.
Schedule
Work schedule of the regulator and temperature reduction.
Fuel consumption
Graphical graph of fuel consumption. NOTE: Tab available only in controllers with dedicated software by producer.
Device settings
Information about regulator and additional modules, possibility to change the address of regulator installation.
User is required to know the operation of the regulator in order to modify its values.
UID: B491JAKZ32C1I18800100
Info
OK
B491JAKZ32C1I18800100
UID
Info
Page 13
13
Devices
Option to read parameters from the list of registered devices in one ecoNET account.
My account Logout
Add a new device UID to the list for ecoNET account and logout.
Select a Web site language.

10.1 Current data

The Current Data tab includes tiles with values of basic regulator operation parameters. A parameter to be modified is indicated by
symbol. Just click on this tile and the value change window will appear, where set the new parameter value with the slider and then confirm with the Save button.
Exit with modification without saving a new
setting is possible by clicking on the symbol.

10.2 Diagram

The Diagram tab includes graphical connection diagram between regulator and heating system in the building with readouts of parameters from sensors in particular points of the installation. A parameter to be modified is indicated by
additional symbol.
Just click in the edit box and the value change window will appear, where set the new parameter value with the slider and confirm with the Save button.
Exit with modification without saving a new
setting is possible by clicking on the symbol.

10.3 User and service parameters

The basic parameters of the regulator work are displayed in the User parameters tab and can be modified by the user. Advanced parameters are displayed in the Service parameters tab and can only be modified after entering a service password. All displayed parameters are grouped accordingly. Click on the name of the selected parameter group and expand the list of available parameters. Parameters to be modified is
indicated by symbol. In order to change, select the appropriate parameter name, click on the parameter, in the additional window that appears, set the new parameter value with the slider and confirm with the Save button. Exit with modification without saving a new
setting is possible by clicking on the symbol.

10.4 Heat yield graph

The Heat yield chart available only for solar controllers ecoSOL301, ecoSOL400, ecoSOL500. The graph is generated based on the data read from the regulator, from the period: Last week, Current month, Current year, years. It can also read the instantaneous power of the solar collector and the total efficiency.

10.5 Data history

The Data history tab enables to readout registered parameters concerning operation
Page 14
14
of the whole heating system in a selected time and present it in the form of a graph. Choose a time period for data readout by clicking From: or To: (select date and time in a calendar) or time interval: Last night, last week, last month. The selection is accepted by the Generate scheme button. Then select from the list below the graph the parameters that will be shown in this graph. By specifying the choosing time zone in the graph, you can rescaling this area on more accurately.
In addition, clicking the symbol causes the "nodes" to be displayed in the graph. This is information about the time and value of a single sample of data sent by the regulator to ecoNET24.
Return to the initial graph by pressing the
symbol.
The graph data can be saved as a *.CSV or
*.PNG file when you press symbol.

10.6 Alarms

In the Alarms tab, user can read:
a list of registered alarms and other
events sent by the regulator,
a type of alarm, event and period of its
occurrence is displayed. Log into www.econet24.com external server in order to display all logs of alarm conditions from the beginning of operation of the controller. Logging into a local LAN network gives a possibility to see only 100 newest logs. Alarm notices can be sent on e-mail. It enables the user to react fast in order to restore normal operation of the regulator.

10.7 Schedule

In the Schedule tab user have the option of setting the time intervals, according to the
list after clicking on the symbol:
reduction preset temperature of the
heating circuits for boiler regulators. Turn on the schedule by selecting On for the available circulation from the list, and enter the decreasing temperature value in the Decrease field, .e.g. 10°C. On a bar chart daily graph (24 hours), click on the appropriate bars (each bar corresponds to 30 minutes), which allows to set the active temperature reduction in the selected time interval. Once set, choose Save.
Page 15
15
Decreasing of preset temperature can be set separately for all days of the week.
In the example above, on Tuesday, the preset temperature for the heating circuit is
reduced by 10°C between 6:00 and 7:30 and
15:30 to 19:00. In other ranges, the preset temperature will not be lowered.
switch on or off for heat pump circuits.
working in schedule or fixed value for
solar regulator.

10.8 Fuel consumption

In the Fuel consumption tab user can read the fuel consumption in kilograms in a daily cycle (every 1 hour) or a monthly cycle (every 1 day).

10.9 Device settings

The Device settings tab enables to:
change the regulator installation address,
reading basic Wi-Fi network parameters,
readout a software version in the
regulator module and additional modules or panels,
update internal ecoNET300 software.
The ecoNET24 server periodically checks availability of new software version for the
ecoNET300 module. It displays information concerning a new software version. All the user needs to do is to press Update button.
In the Settings tab in local version, user can:
read the IP address and status of
Ethernet or Wi-Fi network,
read the Wi-Fi signal strength and the
quality of his signal,
display information about ecoNET24
server, its status and availability. After
pressing Check server availability
button, user can check if the external
server is available from a level of Internet
browser (excluding ecoNET300 Internet
module),
read information concerning selected
controller: identifier, UID number,
software version in controller module,
additional modules and panels,
update software to ecoNET300 module,
change login parameters: login and
password. When changing Wi-Fi network, click Refresh, select Network name, and used Type of
security (e.g. WPA2 Personal) and enter Password to a selected network.
All modifications must be confirmed by Save button.

11. Mobile application

The Android and iOS mobile application allows remote access via smartphone, tablet only to controllers equipped with the ecoNET300 internet module. The application uses an Internet connection and a user account on the www.econet24.com website.
The applications works only with ecoNET24 server, so should be need to sign up for an ecoNET account to use them.
Software update process can be shorter or longer depending on the speed of Internet connection. Do not disconnect the device from a power supply during update process because it will cause its damage.
Page 16
16
The application allows to preview and efficiently configure the most important parameters of the regulator. In this regard, it primarily provides:
• preview basic operating parameters
• possibility to modify values of selected
parameters
• view and edit time schedules
• reading the alarm list.
The ecoNET.apk for Android application is available for free download directly under the link:
The ecoNET.app for iOS application is available for free download directly under the link:
12. Restoring default user name and
password
Default username and password (user: admin, password: admin) can be restored with the use of WPS/RESET button located near indicators on the ecoNET300 housing. The ecoNET300 module has to be connected to power supply:
1. Push WPS/RESET button during normal
module operation.
2. Hold this button pressed for at least 10
seconds.
3. Release the WPS/RESET button.
4. A LED indicator near the button should
flash several times.
5. Wait for app. 2 minutes.
6. The module will automatically start up
and connect with the Internet.
In case the user has forgotten his password for logging in the Internet module, it is possible to restore default data with the use of a button on the ecoNET300 housing.
Page 17
17
7. Default username and password will be
restored (user: admin, password: admin).
Page 18
18
Page 19
Page 20
ul. Wspólna 19, Ignatki
16-001 Kleosin
Poland
plum@plum.pl
www.plum.pl