Total Control TRF-ZW1 User Manual

TRF-ZW1 Z-Wave Extender
Owner’s Manual
TRF-ZW1 Z-Wave Extender Owner's Manual © 2014 Universal Remote Control, Inc.
The information in this Owner’s Manual is copyright protected. No part of this manual may be copied or reproduced in any form without prior written consent from Universal Remote Control, Inc.
UNIVERSAL REMOTE CONTROL, INC. SHALL NOT BE LIABLE FOR OPERATIONAL, TECHNICAL OR EDITORIAL ERRORS/OMISSIONS MADE IN THIS MANUAL.
The information in this Owner’s Manual may be subject to change without prior notice.
URC - Control the Experience is a registered trademark of Universal Remote Control, Inc.
Total Control is a registered trademark of Universal Remote Control, Inc.
All other brand or product names are trademarks or registered trademarks of their respective companies or organizations.
500 Mamaroneck Avenue, Harrison, NY 10528
Phone: (914) 835-4484 Fax: (914) 835-4532
TRF-ZW1 EXTENDER
Congratulations!
Thank you for purchasing URC’s TRF-ZW1 Z-Wave Extender for the Total Control system. The Z-Wave Extender receives commands from a Total Control system and sends those commands over the Z-Wave network to third-party products such as door locks, lights etc. Some compatible third-party products are capable of sending metadata back to a Total Control user interface when using URC’s two-way modules.
Features and Benefits
Control Z-Wave products with your Total Control system
Your Total Control system receives commands, converts them to
Z-Wave signals and then transmits the signals to your products. Also,
while at home or away, control your Z-Wave products using URC’s mobile apps from your mobile devices.
Monitor compatible Z-Wave products While using applicable URC two-way modules, monitor Z-Wave
products with metadata feedback on a Total Control remote, keypad, or mobile device.
● Pairing just got easier
The included batteries allow for roaming and easier pairing of hard-to-reach Z-Wave products installed throughout the home.
Remote Device Management & Configuration Access the TRF-ZW1’s user interface via its online site whether you
are at home or away. Register a free account for basic control and
Z-Wave configurations from home, or subscribe to a yearly account
to access the TRF-ZW1 from anywhere else.
Parts Guide
The TRF-ZW1 Extender includes:
1 - TRF-ZW1 Extender 1 - Ethernet Cable 1 - Power Adaptor 4 - AA Batteries 1 - Owner’s Manual
1
TRF-ZW1 EXTENDER
TRF-ZW1 Top Panel Descriptions
Power LED: Illuminates to indicate the TRF-ZW1 is powered.
Ready: Illuminates to indicate it is ready to receive data.
Network: Illuminates to indicate communication to the home network.
Error: Please consult the troubleshooting section of the URC MIOS documentation site. http://urc-docs.mios.com/doc.php
Battery button: This button is used to enter battery pairing mode
while pairing devices in various locations.
1. Disconnect the TRF-ZW1 from the network and power cable.
2. Insert 4 AA batteries into the bottom of the unit.
3. Press and Hold the “Battery” icon on the top of the unit for 5 seconds.
The Power light will start to flash Blue for 30 seconds.
After 10 more seconds the ready light will start to flash amber. By
default the unit goes into Pairing (Include) mode automatically.
+ (pairing button): Stated above the TRF-ZW1 defaults to Pairing (Include) when battery power is activated.
1. The Ready light will slowly flash to show it is ready to pair a device.
2. Go to the device you wish to pair and perform its instructed pairing method.
3. The ready light will quickly start flashing for 2 seconds to verify the device has been paired.
4. You can continue to pair devices while in pairing mode.
5. When you are done pairing (including) devices press the [+] button to save.
The Ready light will not flash for a moment while saving.
6. To turn off Battery mode press and hold the [+] button for 5 seconds.
2
TRF-ZW1 EXTENDER
7. Connect the TRF-ZW1 back to the network and power cables then login to the TRF-ZW1 programming software. You will find the items add to the “No Rooms” section.
– (un-pairing button): After the TRF-ZW1’s battery mode is activated and the ready light is flashing for pairing (include) you will press the [-] on the unit. When the [-] button is pressed the ready light will flash slightly faster in un-pairing (exclude) mode, then in pairing (include) mode).
1. Go to the device you wish to un-pair (exclude) from the system and perform the devices instructed in the un-pairing method.
2. The Ready light will quickly flash for 2 seconds to verify the
item has been un-paired (excluded).
3. When you are done un-pairing devices press the [-] to save the
changes.
The Ready light will pause from flashing for a moment to confirm.
4. To turn off battery mode press and hold the [+] for 5 seconds.
5. Connect the TRF-ZW1 back to the network and power cables then login to the TRF-ZW1 programming software. You will find the items removed are no longer in the program.
Reset button: WARNING!!! Pressing this button will set the unit back to factory settings. Press and hold the recessed button adjacent to the (-) unpair button for 10 seconds until the lights turn off.