
MAINTENANCE INSTRUCTIONS
WITH
ILLUSTRATED PARTS LIST
HALON 1/ 1,2/ 2,5 AIR TOTAL
List of Portable Fire Extinguishers
Part No. Type:
74-00 HAL 1,0
74-20 HAL 1,2
74-21 HAL 1,2 (LH)
76-00 HAL 2,5
COMPONENT MAINTENANCE MANUAL
ATA 26-24-05 I 74/76-00 dated May 2014
Subject to change without notice Replaces H 74/76-00 dated October 2012
TOTAL Feuerschutz GmbH
Industriestr. 13
D-68526 Ladenburg
Page 1 of 13

MAINTENANCE INSTRUCTIONS
HALON 1 / 1,2 / 2,5 AIR TOTAL
Inspection Record
ATA 26-24-05 I 74/76-00 dated May 2014
Subject to change without notice Replaces H 74/76-00 dated October 2012
Page 2 of 13

MAINTENANCE INSTRUCTIONS
HALON 1 / 1,2 / 2,5 AIR TOTAL
Table of contents
Index Page Release
Cover page 1 January 2005
Inspection record sheet 2 August 2003
Table of contents 3 May 2014
Description 4 August 2003
Operating instructions 5 August 2003
Technical data 5 January 2005
Inspection regulations 6 October 2012
Disassembly and cleaning 7 August 2003
Filling instructions 8 May 2008
Filling instructions 9 May 2014
Filling instructions 10 May 2014
Storage 10 August 2003
Parts list 11 January 2005
Parts list illustration 12 May 2014
Annex temperature curves 13 August 2003
ATA 26-24-05 I 74/76-00 dated May 2014
Subject to change without notice Replaces H 74/76-00 dated October 2012
Page 3 of 13

MAINTENANCE INSTRUCTIONS
HALON 1 / 1,2 / 2,5 AIR TOTAL
Description (see illustration 1)
(1) Portable fire extinguishers type HAL 1, HAL 1,2 and HAL 2,5 are intended for use in
aircraft pilot- and passenger cabins.
They are filled with HALON 1211. The fire extinguishers are approved for the attack
on flammable solids, flammable liquids, flammable gases and for fires in the presents
of electrical tensions up to 1000 Volt.
The extinguishers are designed for a one hand operation.
(2) Range of application
(a) Fire Class
ABC
(b) Extinguishing agent
HALON 1211
(3) The fire extinguisher consists of 3 main components
(a) The cold drawn steel container, pressure tested to 30 bar (427 psi),
painted red RAL 3000.
(b) The discharge valve with siphon tube and pressure gauge.
The valve is pressure lever operated and can be shut-off.
The carrying handle is movable.
(c) The extinguishing agent HALON 1211 is nitrogen super pressurized.
Filling pressure: 11 bar (156.5 psi) at 15°C (59°F).
Illustration 1
ATA 26-24-05 I 74/76-00 dated May 2014
Subject to change without notice Replaces H 74/76-00 dated October 2012
Page 4 of 13