  • Model: VT130G1
  • Rated Capacity: 1.5 to 33 KVA (1 to 30 horsepower)
  • Power Voltage: 460V, 3 Phase
  • Control System: Sinusoidal Wave PWM Control System
  • Maximum Output Voltage: 3-phase, 460V
  • Frequency: 60 Hz
  • Overload Capacity: 180 percent for up to 60 seconds; 110 percent on a continuous basis
  • Maximum Rated Current: 98 Amperes A maximum
  • Maximum Motor KW: 0.78 to 22 KW
  • Speed Reference: 0 to 12V DC or 4 to 20 mA
  • Time Taken to Achieve Full Speed: 1 to 20 seconds
  • Protection: Stall prevention, overcurrent shortcircuit, overvolt, under volt, momentary power drop, and fuse input protection
  • Operation Temperature Range: 0 to 40°C
  • Relative Humidity: Non condensing below 90%
  • Weight Range: 19-106 pounds model.d
  • Additional Applications: Fault detection as form-C contact fault relay with 250V AC and 1 Ampere of resistive load
  • Display: 4 digit 7 segment display with CHG LED indicator and 2 digit LCD
  • NEMA Rating: NEMA 1

Frequently Asked Questions

  • What is the rated capacity range of the VT130G1?

The rated capacity range for this motor is from 1.5KVA to thirty three kVA.

  • What kind of motors can the VT130G1 operate?

General use induction motors can be driven by the VT130G1.

  • On what supply voltages does the VT130G1 and said Inverter work?

It works on a supply of 460 Volt, 3 phase.

  • What is their overload capacities of the VT130G1?

The inverter is rated 180% overload for up to 60 seconds and repeatable 110% overload continuously.

  • What is the speed reference input applicable for the VT130G1?

The speed reference is 0 to 12 VDC or 4 to 20 mA input.

  • What weather conditions can the VT130G1 function in?

The unit can operate at temperature ranging 0 to 40°C and humidity of not more than 90% and quite non-condensing.

  • What safeguards does the VT130G1 provide?

Safeguards against stall, overcurrent, short circuit, overvoltage, undervoltage, momentary power failure is supplied with and input fuse is also deployed for current protection.

  • Could the VT130G1 measure and display faults, if possible what are these measures?

Yes, the system uses a fault relay fitted with form-C contacts that work during an overcurrent, short circuit, overvoltage or undervoltage detection or during ranges set on these conditions.

  • What instrument is being used to measure and view the functions of the VT130G1?

A 4-digit 7-segment digital display fitted in conjunction with CHG LEDs is used.

  • What weight range do models in the VT130G1 series weight?

VT130G1 series varies with weight values between19 lbs to 106 lbs according to the model.

to your department for this courageous act that promotes entrepreneurship. Please use the link above to contact our office directly if you have any questions about microcredit or other associated issues. Finally, be sure to check our lectures and research hard for all the current standout ideas that define entrepreneurship today. They have taken their time to respond to you and thus you need to acknowledge them, lest they cease to respond to you. However, sometimes one needs to recruit a few more people to get a network up and running.