PRECAUTIONS FOR SAFETY
•
Do not install, repair, open or remove the cover. It may expose you
to dangerous voltages. Ask the dealer or the specialist to do this.
•
Turning off the power supply will not prevent potential electric
shock.
•
DANGER
WARNING
CAUTION
1
INDOOR UNIT DISPLAY
Models: RAS-10, 13, 16SKV(R) Series, RAS-M10, 13, 16SK(C)V Series,
Hi POWER FILTER PURE TIMER OPERATION
12
Models: RAS-10SKV-E
CLEANING
RESET TIMER OPERATION
32 1
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push CLOCK
2. Press
3. Press
Remote Control Reset
1. Remove the battery.
2. Press
3. Insert the battery.
3
AIRFLOW DIRECTION
Press
1
desired vertical direction.
Press
2
automatically and press again to stop.
For horizontal direction, adjust
3
manually.
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by come operation mode.
The appliance shall be installed in accordance with national wiring
regulation.
•
Means for disconnection from the supply having a contact
separation of at least 3 mm in all poles must be incorporated in the
fi xed wiring.
•
Do not expose your body directly to cool air for a long time.
•
Do not insert your fi nger or any article into the air inlet/outlet.
•
When an abnormality (burning smell, etc.) occurs, stop the air
conditioner and disconnect the power supply or turn off the
breaker.
•
Do not wash the unit with water. It may cause an electric shock.
•
Do not use this air conditioner for other purposes such as
preserving food, breeding animal, etc.
•
Do not step or put anything on the indoor/outdoor unit. It may
cause an injury or damage the unit.
•
Do not touch aluminium fi n because it may cause an injury.
•
Before cleaning the unit, turn off the main switch or the circuit
breaker.
•
When the unit won’t be used for a long time, turn off the main
switch or the circuit breaker.
•
It is recommended that maintenance be performed by a specialist
when the unit has been operated for a long time.
45
3
●
by tip of the pencil.
ON
OFF
or
SET
: Set the time.
RESET
6
: adjust the time.
1 Hi POWER (Green)
2 FILTER (Orange)
3 PURE (Blue) (10, 13, 16SKVR-E Series)
FAN-ONLY (Orange)
3
(M10, 13, 16SKCV-E Series)
3 PRE DEF (DE-FROST) (Orange)
(13, 16SKV-E, M10, 13, 16SKV-E Series)
4 TIMER (Yellow)
5 OPERATION (Green)
6 RESET button
1 OPERATION (Green)
2 TIMER/CLEANING (Yellow)
3 RESET button
.
FIX
: Move the louver in the
SWING
: Swing the air
4
REMOTE CONTROL
1 Infrared signal emitter
1
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 On timer button (ON)
9 Off timer button (OFF)
! Sleep timer button (SLEEP)
" Setup button (SET)
# Clear button (CLR)
$ Memory and Preset button (PRESET)
% One Touch button (ONE-TOUCH)
& High power button (Hi-POWER)
( Economy button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button (COMFORT SLEEP)
+ Plasma Air Purifi er button (PURE)
(RAS-10, 13, 16SKVR-E Only)
PRESET
$
ONE-TOUCH
%
2
QUIET
)
SWING
+
6
7
TIMER
8
SLEEP
!
.
,
TEMP
PURE
FIX Hi-POWER ECO
ON
FILTER
CHK
FAN
5
SLEEP
4
3
~
&
(
CLR
#
9
SET
"
-
MODE
COMFORT
OFF
CLOCK
, Filter reset button (FILTER)
- Clock Reset button (CLOCK)
. Check button (CHK)
5
ONE-TOUCH
Press the “ONE-TOUCH” button for fully automated operation that is customised
to the typical consumer preferences in your region of the world. The customised
settings control temperature air fl ow strength, air fl ow direction and other settings
to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer
other settings you can select from the many other operating functions of your
Toshiba unit.
Press
6
To automatically select cooling, heating, or fan only operation
1. Press
2. Press
7
1. Press
2. Press
Cooling: Min. 17
A
C
L
3. Press
HIGH .
8
ONE-TOUCH
: Start the operation.
AUTOMATIC OPERATION
MODE
: Select A.
TEMP
: Set the desired temperature.
COOLING / HEATING / FAN ONLY OPERATION
MODE
: Select Cool , Heat , or Fan only .
TEMP
: Set the desired temperature.
o
C, Heating: Max. 30oC, Fan Only: No temperature indication
FAN
: Select AUTO, LOW , LOW+ , MED , MED+ , or
DRY OPERATION (COOLING ONLY)
For dehumidifi cation, a moderate cooling performance is controlled
automatically.
1. Press
2. Press
9
AIR PURIFYING OPERATION
During air conditioner operation
Press
MODE
: Select Dry .
TEMP
: Set the desired temperature.
(RAS-10, 13, 16SKVR-E Only)
PURE
to start and stop plasma air purifi er and air ionizer operation.
The plasma air purifi er and air ionizer can be activated or deactivated during air
conditioner is stopped and the air ionizer starts in conjunction with plasma air
purifi er operation.
Note: The FILTER indicator (orange) turns on after PURE operation is performed
for about 1000 hours.
10
Hi-POWER OPERATION
To automatically control room temperature and airfl ow for faster cooling or heating
operation (except in DRY and FAN ONLY mode)
Press
11
Hi-POWER
: Start and stop the operation.
ECO OPERATION
To automatically control room to save energy (except in DRY and FAN ONLY
mode)
Press
ECO
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1 degree/
hour for 2 hours (maximum 2 degrees increase). For heating operation the
set temperature will decrease.