PRECAUTIONS FOR SAFETY
Do not install, repair, open or remove the cover. It may expose you to •
dangerous voltages. Ask the dealer or the specialist to do this.
Turning off the power supply will not prevent potential electric shock.•
The appliance shall be installed in accordance with national wiring •
DANGER
WARNING
CAUTION
1
INDOOR UNIT DISPLAY
Hi POWER FILTER PURE TIMER OPERATION
12
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type) following the (+)
and (–) positions.
Clock Setup
1. Push
2. Press
3. Press
Remote Control Reset
Press
3
AIRFLOW DIRECTION
Press : Move the louver in the
1
desired vertical direction.
Press : Swing the air automatically
2
and press again to stop.
regulation.
Means for disconnection from the supply having a contact separation of •
at least 3 mm in all poles must be incorporated in the fi xed wiring.
Do not expose your body directly to cool air for a long time.•
Do not insert your fi nger or any article into the air inlet/outlet.•
When an abnormality (burning smell, etc.) occurs, stop the air •
conditioner and disconnect the power supply or turn off the breaker.
This appliance is not intended for use by persons (including children) •
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the •
appliance.
Do not use any refrigerant different from the one specifi ed for •
complement or replacement. Otherwise, abnormally high pressure may
be generated in the refrigeration cycle, which may result in a failure or
explosion of the product or an injury to your body.
Do not wash the unit with water. It may cause an electric shock.•
Do not use this air conditioner for other purposes such as preserving •
food, breeding animal, etc.
Do not step or put anything on the indoor/outdoor unit. It may cause an •
injury or damage the unit.
Do not touch aluminium fi n because it may cause an injury.•
Before cleaning the unit, turn off the main switch or the circuit breaker.•
When the unit won’t be used for a long time, turn off the main switch or •
the circuit breaker.
It is recommended that maintenance be performed by a specialist when •
the unit has been operated for a long time.
The manufacturer shall not assume any liability for the damage caused •
by not observing the description of this manual.
45
3
RESET
6
by tip of the pencil.
: adjust the time.
: Set the time.
for reset.
Hi POWER (Green)
1
FILTER (Orange)
2
PURE (Blue)
3
TIMER (Yellow)
4
OPERATION (Green)
5
RESET button
6
4
REMOTE CONTROL
Infrared signal emitter
1
Memory and preset button (PRESET)
2
Start/Stop button
3
Temperature up/down and Timer
4
or clock up/down button (TEMP.)
Mode select button (MODE)
5
Swing louver button (SWING)
6
Fan speed button (FAN)
7
One Touch button (ONE-TOUCH)
8
Set louver button (FIX)
9
8 degree celcius operation button (8°C)
0
Economy button (ECO)
-
High power button (Hi-POWER)
=
Plasma Air Purifi er button (PURE)
~
Comfort sleep button (COMFORT SLEEP)
!
Power selection button (POWER-SEL)
@
On timer button (ON)
#
Off timer button (OFF)
$
Setup button (SET)
%
Clear button (CLR)
^
Clock setup button (CLOCK)
&
Check button (CHECK)
*
Filter reset button (FILTER)
(
Reset button (RESET)
)
5
ONE-TOUCH
Press the “ONE-TOUCH” button for fully automated operation that is customised
to the typical consumer preferences in your region of the world. The customised
settings control temperature air fl ow strength, air fl ow direction and other settings
to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer
other settings you can select from the many other operating functions of your
Toshiba unit.
Press
6
AUTOMATIC OPERATION
To automatically select cooling, heating, or fan only operation
1. Press
2. Press
3. Press
MED+
7
COOLING / HEATING / FAN ONLY OPERATION
1. Press : Select Cool , Heat , or Fan only .
2. Press
Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only: No temperature indication
3. Press : Select AUTO, LOW , LOW+ , MED ,
MED+
Note: QUIET is supper low fan speed for quiet operation.
8
DRY OPERATION (COOLING ONLY)
For dehumidifi cation, a moderate cooling performance is controlled automatically.
1. Press
2. Press
9
AIR PURIFYING OPERATION
During air conditioner operation
Press
The plasma air purifi er and air ionizer can be activated or deactivated during air
conditioner is stopped and the air ionizer starts in conjunction with plasma air
purifi er operation.
Note: The FILTER indicator (orange) turns on after PURE operation is performed
for about 1000 hours.
10
Hi-POWER OPERATION
To automatically control room temperature and airfl ow for faster cooling or heating
operation (except in DRY and FAN ONLY mode)
Press
: Start the operation.
: Select A.
: Set the desired temperature.
: Select AUTO, LOW , LOW+ , MED ,
, HIGH , or Quiet .
: Set the desired temperature.
, HIGH , or Quiet .
: Select Dry .
: Set the desired temperature.
to start and stop plasma air purifi er and air ionizer operation.
: Start and stop the operation.
2
3
5
8
10
13
16
17
20
21
1
4
6
7
9
11
12
14
15
19
18
23
22
11
ECO OPERATION
For horizontal direction, adjust manually.
3
Note:
Do not move the louver manually by others.•
The louver may automation positioning by some operation mode.•
1110250187.indd 21110250187.indd 2 4/18/11 2:48:56 PM4/18/11 2:48:56 PM
To automatically control room to save energy (except in DRY and FAN ONLY
mode)
Press
Note: Cooling operation; the set temperature will increase automatically 1
degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation the set temperature will decrease.
: Start and stop the operation.

12
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or stop •
without using the remote control.
Operation mode is set on AUTOMATIC operation, preset •
temperature is 25°C and fan operation is automatic
speed.
13
TIMER OPERATION
Setting the ON Timer Setting the OFF Timer
Press for enter ON timer setting
1
Press for select desired ON
2
3
Press for set timer. Press for set timer.
4
Press for cancel timer. Press for cancel timer.
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
1
Press for enter ON timer setting
Press for select desired
2
3
Press for enter OFF timer setting
During the daily timer is activating, both arrows (• , ) are indicated.
Note:
Keep the remote control in accessible transmission to the indoor unit; •
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.•
14
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by the
unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
The P mark displays.
3. Press
15
AUTO RESTART OPERATION
To automatically restart the conditioner after the power failure (Power of the unit must
be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the
operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the
operation. (3 beep sound but OPERATION lamp does not blink)
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does •
not activate.
16
POWER-SELECTION OPERATION
This function is used when its circuit breaker is shared with other electrical
appliances. It limits the maximum current/ power consumption to 100%, 75% or
50%. The lower the percentage, the higher the saving and also the longer the
compressor lifetime.
Press
When the level is selected, PWR-SEL level fl ashes on LCD display for 3 •
seconds. In case of 75% and 50% level, number “75” or “50” also fl ashes
for 2 seconds.
Due to the reason that POWER SELECT FUNCTION limits the maximum •
current, inadequate capacity may occur.
17
COMFORT SLEEP OPERATION
To save energy while sleeping, automatically control air fl ow and automatically
turn OFF.
Press
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
18
8°C OPERATION
1. Press
2. Press
Note: 8°C will operate in Heating mode only. If Air conditioner performs in cooling
operation (including automatic cooling) or dry operation it will change to
heating operating.
timer.
ON timer.
: Operate the preset operation.
: Select: (for 100%), (for 75%), (for 50%)
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
button to change to 8°C set temperature heating operation.
to adjust setting temperature from 5°C to 13°C.
Press for enter OFF timer setting
Press for select desired OFF
Press for select desired OFF
4
5
Press
Press again during the
6
( or ) blink.
for 3 seconds to memorize the setting.
timer.
timer.
19
MAINTENANCE
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER button on
the remote control.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.•
No benzine, thinner, polishing powder or chemically-treated duster.•
Cleaning the air ionizer (Once every six months)
1. Turn off air conditioner using remote control and power supply.
2. Fully open the vertical air fl ow louvers by hand.
3. Use a toothbrush to rub the ends of metal pin three or four times.
Note: Do not use cotton swabs or other objects with fl uff.
Cleaning the plasma air purifi er unit (About 1000 hours performed)
1. Turn off air conditioner using remote control and power supply.
2. Take out the air inlet grille (See detail in installation manual).
3. Take out the plasma air purifi er by grasp the handle, and the pull it out.
4. Soak in hot water at 40°C to 50°C for about 10 to 15 minutes and rub up, down, left,
right and rub surface gently with a sponge.
5. Allow to dry thoroughly in the shade.
6. Attach the plasma air purifi er by grasp the handle
and insert into the right and left guide rails.
7. Press both ends of the plasma air purifi er until the
protrusions on both sides of the plasma air purifi er
are completely inserted.
8. Attach the air fi lter, and then close the air inlet grille.
20
SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
will continue to run for other 30 minutes, then it will turn off automatically.
This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
seconds.
21
OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated for 3
minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating operation
starts.
3. Warm air control: When the room temperature reaches the set temperature, the fan
speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into the room. When
the outdoor temperature is too low, use another recommended heating apparatus in
combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit where it will
not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal because
the cracking sound may be caused by expansion/contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Operation
Heating –15°C ~ 24°C –20°C ~ 24°C Less than 28°C
Cooling –10°C ~ 46°C 21°C ~ 32°C
Dry –10°C ~ 46°C 17°C ~ 32°C
22
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
The power main switch is •
turned off.
The circuit breaker is activated •
to cut off the power supply.
Stoppage of electric current•
ON timer is set.•
23
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
“00” will be shown on the display.
4. Press
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note:
1. Repeat above step to reset
Remote Control to be A.
2. Remote Control A has not “A”
display.
3. Default setting of Remote Control
from factory is A.
button is pressed once during “Cool” or “Dry” mode, the fan
more 2 times within 30
Temp.
Outdoor Temperature
-TR, -A Series -EE Series
Cooling or Heating is abnormally low.
The fi lters are blocked with dust.•
The temperature has been set improperly.•
The windows or doors are opened.•
The air inlet or outlet of the outdoor unit is blocked.•
The fan speed is too low.•
The operation mode is FAN or DRY.•
POWER SELECT FUNCTION is set at 75% or 50%.•
button on the Remote Control by the tip of the pencil.
during pushing . “B” will show on the display and “00”
Room
Temperature
EN
1110250187.indd 31110250187.indd 3 4/18/11 2:49:01 PM4/18/11 2:49:01 PM