4-1 Indoor Unit (RAS-24UKHP-ES,18UKHP-ES)
4-2 Outdoor Unit (RAS-24UAH-ES)
4-3 Outdoor Unit (RAS-18UAH-ES)
4-4 Indoor Unit (RAS-24UKP-ES, 18UKP-ES)
4-5 Outdoor Unit (RAS-24UA-ES)
4-6 Outdoor Unit (RAS-18UA-ES)
7-1 Outline of Air Conditioner Control
7-2 Description of Operation Circuit
7-3 ECO Mode
7-4 Hi POWER Mode
7-5 High-Temperature Limit Control
7-6 Low-Temperature Limt Control
7-7 Defrosting Operation
7-8 Auto Restart Function
7-9 Filter Check Lamp
– 1 –
TCTC Service Manual 18/24UKHP-ES (EN) File No. SVM-01006
8. INSTALLATION PROCEDURE
8-1 Safety Cautions
8-2 Installation Diagram of Indoor and Outdoor Units
8-3 Installation
8-4 Indoor Unit
8-5 Outdoor Unit
8-6 Others
9. TROUBLESHOOTING CHART
9-1 Troubleshooting Procedure
9-2 Basic Check Items
9-3 Primary Judgement
9-4 Self-Diagnosis by Remote Control (Check Code)
9-5 How to Diagnose Faulty Part
9-6 Troubleshooting for Indoor Unit
9-7 Troubleshooting for Wiring (Interconnect cable and Serial Signal Wire)
9-8 Troubleshooting for P.C. Board
9-9 Troubleshooting for Remote Control
10. PART REPLACEMENT
10-1 Indoor Unit
10-2 Outdoor Unit (RAS-24UAH-ES, 24UA-ES)
10-3 Outdoor Unit (RAS-18UAH-ES, 18UA-ES)
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (1)
11-2 Indoor Unit (2)
11-3 Outdoor Unit
• This air conditioner is charged with HFC (R-410A)
• This air conditioner requires special service tools
that does not deplete the Ozone layer.
for the refrigerant R-410A.
– 2 –
TCTC Service Manual 18/24UKHP-ES (EN) File No. SVM-01006
Depthmm208
Net weightkg12
Evaporator typeFinned tube
Indoor fan typeCross flow fan
High fanm3/h950950950750 800750
Air volumeMedium fanm3/h750800750650700650
Low fanm3/h 600650600530570530
Fan motor outputW30
Air filterHoneycomb woven filter with PP frame
OUTDOOR UNITRAS-24UAH-ESRAS-24UA-ESRAS-18UAH-ESRAS-18UA-ES
Depthmm310310300300
Net weightkg67645150
Condenser typeFinned tube
Outdoor fan typePropeller fan
Airflow volumem3/h3400 3600 3400 3600340036001800 2000 1800 200018002000
Fan motor outputW6542
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
IndoorOutdoor
– 19 –
TCTC Service Manual 18/24UKHP-ES (EN) File No. SVM-01006
6. CONTROL BLOCK DIAGRAM
6-1. RAS-24UKHP-ES, 18UKHP-ES
Indoor Unit Control Panel
Heat Exchanger Sensor
Temperature Sensor
Functions
• Louver Control
• 3-minute Delay at Restart for Compressor
M.C.U.
Operation
Display
Timer
Display
Infrared Rays Signal Receiver
Infrared
Initiallizing Circuit
Rays
Clock Frequency
Oscillator Circuit
Power Supply
Remote
Circuit
Control
Noise Filter
From Outdoor Unit
REMOTE CONTROL
• Motor Revolution Control
• Processing
(Temperature Processing)
• Timer
• Serial Signal Communication
Louver ON/OFF Signal
Serial Signal Transmitter/Receiver
Serial Signal Communication
Remote Control
Louver Driver
Infrared Rays
Filter Sign
Display
PRE DEF.
Sign Display
Hi Power Sign
Display
Indoor Fan
Motor
Louver Motor
Operation (START/STOP)
Operation Mode Selection
AUTO, COOL, DRY, HEAT, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Hi power
Filter Reset
Sleep Timer Setting
– 20 –
TCTC Service Manual 18/24UKHP-ES (EN) File No. SVM-01006
6-2. RAS-24UKP-ES, 18UKP-ES
Indoor Unit Control Panel
Heat Exchanger Sensor
Functions
• Louver Control
M.C.U.
Operation
Display
Temperature Sensor
Infrared Rays Signal Receiver
Initiallizing Circuit
Infrared
Rays
Clock Frequency
Oscillator Circuit
Power Supply
Remote
Circuit
Control
Noise Filter
From Outdoor Unit
• 3-minute Delay at Restart for Compressor
• Motor Revolution Control
• Processing
(Temperature Processing)
• Timer
Outdoor unit
ON/OFF Signal
Relay Driver
Relay RY04
Outdoor Unit
Louver ON/OFF Signal
Louver Driver
Timer
Display
Filter Sign
Display
Fan Only
Sign Display
Hi Power Sign
Display
Indoor Fan
Motor
Louver Motor
REMOTE CONTROL
Infrared
Rays
Remote Control
Operation (START/STOP)
Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Hi power
Filter Reset
Sleep Timer Setting
– 21 –
TCTC Service Manual 18/24UKHP-ES (EN) File No. SVM-01006
7. OPERATION DESCRIPTION
7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner , which uses a
DC motor for an indoor fan. The DC motor drive
circuit is mounted in the indoor unit. And electrical parts
which operate the compressor and the outdoor fan motor, are mounted in the outdoor unit.
The air conditioner is mainly controlled by the indoor unit
controller. The controller operates the indoor fan motor
based upon commands transmitted by the
remote control and transfers the operation commands to
the outdoor unit controller.
The outdoor unit controller receives operation commands
from the indoor unit, and operates the
outdoor fan motor and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation
commands from the remote control and executes them.
• Temperature measurement at the air inlet of the indoor heat exchanger by the indoor temperature
sensor
• Themperature setting of the indoor heat e xchanger
by the heat exchanger sensor
• Louver motor control
• Indoor fan motor operation control
• LED display control
• Transferring of operation commands to the
outdoor unit
• Receiving of information of the operation status and
judging of the information or indication of error
(2) Role of outdoor unit controller
The outdoor unit controller receives the operation
commands from the indoor controller and executes
them.
• Compressor operation
control
• Operation control of
outdoor fan motor
• Tur ning off the compressor and outdoor fan when
the outdoor unit receives the shutdown command
• Defrost control in heating operation (Temperature
measurement by the outdoor heat exchanger and
control for the four-way valve and the outdoor fan
motor) *Heating and Cooling Model only
Operations according to
the commands from the
indoor unit
7-1-1. Louver Control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [SET] button.
The louver position which is set by [SET] button is
stored in the microcomputer, and the louver is automatically set at the stored position for the next oper ation.
(2) Swing
If [SWING] button is pressed when the indoor unit is
in operation, the vertical air flow louver starts swinging. When [SWING] button is pressed again, it stops
swinging.
7-1-2. Indoor Fan Control (DC Fan Motor)
(1) The indoor fan is operated by the stepless speed
change DC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW , LO W+, MED , MED+ and
HIGH). If A UTO mode is selected, the f an motor speed
is automatically controlled by the difference betw een
the preset temperature and the room termperature.
Table 7-1-1
RAS-24UKHP-ESRAS-18UKHP-ES
MODEL
CoolingHIGH13509501150750
andMED11507501050650
Fan onlyLOW1000600 900530
HeatingMED12008001100700
MODELRAS-24UKP-ESRAS-18UKP-ES
CoolingHIGH13509501150750
andMED11507501050650
Fan onlyLOW1000600 900530
Motor speed Air flow level Motor speed Air flow level
(rpm)(m
HIGH13509501200800
LOW1050650 950570
LOW+=
MED+=
3
/h)(rpm)(m3/h)
LOW+MED
2
MED+HIGH
2
– 22 –
TCTC Service Manual 18/24UKHP-ES (EN) File No. SVM-01006