Toshiba RAS-22LAH-A, RAS-18LKH-A, RAS-18LAH-A, RAS-22LKH-A User Manual

OWNER’S MANUAL
AIR CONDITIONER
For general public use
Indoor Unit Outdoor Unit
RAS-18LKH-A RAS-18LAH-A RAS-22LKH-A RAS-22LAH-A
SPLIT TYPE
)
Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using your Air Conditioner.
A
A
SLEEP
ON/OFF
TEMP.
OWNER ,S MANUAL
CONTENTS
PRECAUTIONS BEFORE OPERATION
UNIT DESCRIPTION REMOTE CONTROL DESCRIPTION REMOTE CONTROL PREPARATION
UNIT OPERATION
AUTOMATIC OPERATION MANUAL OPERATION TIMER OPERATION DISCHARGE AIR LOUVER CONTROL EMERGENCY AND TEST OPERATION AIR CLEANING OPERATION
CARE AND MAINTENANCE
POINTS TO NOTE CLEANING THE FILTERS AND FRONT PANEL
2 6 6
8 11 13 13 14 15 20 21 22 23 23 25
CLEANING THE MAIN UNIT AFTER-SEASON CARE
TROUBLESHOOTING
26 26 27
OWNER,S MANUAL - 2
PRECAUTIONS
Installing and servicing air conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install or service this equipment. Untrained personnel can perform basic maintenance functions such as cleaning the coil and filters, and replacing filters. All other operations should be performed by trained service personnel. When working on air conditioning equipment, observe precautions in the literature, tags and labels attached to the unit.
WARNING
Before performing service or maintenance operations on the system, turn off the main power of the unit. Electric shock can cause personal injury.
WARNING
Use the correct voltage. Using voltage other than specified will damage the unit.
WARNING
Check the power plug. If the power plug is not inserted tightly, or if there is any damage to the power cord, it could result in leakage or electric shock.
WARNING
Do not use the power cord as a means of turning off the unit.
PRECAUTIONS
WARNING
Do not use flammable sprays near the unit. The unit can be damaged by gasoline, benzene, thinners, insecticides and other chemical agents.
WARNING
When unplugging the power plug, do not pull by the power cord. The power cord will get damaged and it can cause electric shock.
OWNER,S MANUAL - 3
WARNING
To avoid the risk of serious electric shock, never splash the indoor and the outdoor unit with water.
WARNING
Do not put hands or objects into the discharge grille of outdoor unit. This unit has a fan running at high speed. It is very dangerous to touch the fan.
WARNING
Use only fuses of the proper amperage.
PRECAUTIONS
WARNING
Be careful to keep the room temperature a comfortable level. A void continuous direct air flow to the occupant, especially in case of sleeping persons or hospital patients.
WARNING
Do not obstruct the front of the discharge grille of both units. This will block air flow, reduce the cooling effect and may result in unit malfunction.
WARNING
OWNER,S MANUAL - 4
Ventilate the room when it becomes stuffy or filled with undesirable odors.
WARNING
Keep heat sources away from the unit; high temperature can cause damage.
WARNING
Set a comfortable temperature. Very low or very high temperature setting consider­ably increase power consumption.
27°C
PRECAUTIONS
WARNING
To circulate the room air only, operate at the FAN mode.
WARNING
In summer, if possible, prevent direct sunlight from entering the room; draw curtains or blinds.
WARNING
OWNER,S MANUAL - 5
Use the timer correctly to maintain comfort conditions.
WARNING
Please read this owner,s manual carefully before operating the unit. It contains further important instructions for proper operation.
BEFORE OPERA TION
UNIT DESCRIPTION
Indoor Unit
OWNER,S MANUAL - 6
ROOM AIR INLET
AIR FILTER
ACTIVE CARBON FILTER &
OPTION 1 : ELECTROST ATIC FILTER
OPTION 2 : PHOTO-CA TALYST FILTER
REMOTE CONTROL SIGNAL RECEIVER
AIR SWING FLAP
VERTICAL LOUVER
ROOM AIR OUTLET
Outdoor Unit
POWER PLUG
LCD REMOTE CONTROL
OUTDOOR AIR OUTLET
OUTDOOR AIR INLET
INDOOR AND OUTDOOR
CONNECTION
DRAIN HOSE
BEFORE OPERA TION
Indoor Unit Display
• UNIT ON(Green): When the unit is switched on by the remote control, a green light will be displayed.
• TIMER(Orange) : When the unit is in reservation mode, an orange light will be displayed.
OWNER,S MANUAL - 7
Switch Panel
EMERGENCY TEST
• EMERGENCY button :
Can be used when the remote control is lost or inoperative.
• TEST button :
Is only used by service men to test the unit operation.
For the usage of EMERGENCY and TEST buttons, refer to EMERGENCY AND TEST OPERA TION, p.21.
BEFORE OPERA TION
REMOTE CONTROL DESCRIPTION
Names and Functions of the Buttons
ON/OFF BUTTON
1
If you press this button, the unit will begin operation. Press the button again, and operation stops. ( Y ou can hear a receiving beep. ) If you press this button immediately after turning off the unit, the compressor will not operate for 3 minutes to prevent overloading.
OWNER,S MANUAL - 8
햾 햽
A
SWING
A
ON/OFF
TEMP.
MODE FAN FLAP
EVERYDAY
CLOCK
TIMER
ON OFF
RST TA
SLEEP
HOUR MINUTE
RESERV.
CANCEL
햷 햹
TEMPERA TURE SETTING BUTT ONS
2
If you set the desired room temperature, then the unit will maintain the room temperature as set . In COOL mode, if the room temperature is higher than the setting, the compressor will automatically turn on to provide a cooling effect. On the other hand, if the room temperature is lower than the setting, the compressor will automatically turn off to stop cooling operation. In HEA T mode, if the room temperature is lower than the setting, the compressor will automatically turn on to provide a heating effect. If the room temperature is higher than the setting, the compressor will automatically turn off to stop heating operation. However,the indoor fan will continue to circulate air even if the compressor is turned off.
SLEEP TIMER BUTTON
3
Press this button to set the SLEEP timer . (Refer to p.19)
OPERA TION MODE SELECTING BUTTON
4
Press this button to select the desired mode. In AUTO mode, the unit will run automatically by selecting COOL or HEA T mode according to the indoor room temperatur e. In DRY mode, the microcomputer of the unit controls the indoor fan motor and makes the outdoor unit automatically turn on and off according to the room temperature, which causes moisture to be removed more effectively. In COOL mode, the unit will run at the normal cooling mode. In FAN mode, only the indoor fan will operate at the selected fan speed and circulate room air . In HEAT mode, the unit will run at the normal heating mode.
BEFORE OPERA TION
OWNER,S MANUAL - 9
FLAP CONTROL BUTTON
6
Controls the discharge air flow direction up and down. ( Refer to p.20 ) On start up, the flaps open automatically according to the operating mode. If you press this button, the flap will move stepwise and the position will be displayed. If you press this button again, the unit operates at “SWING” mode. At operating mode “SWING”, the flap will swing up and down continuously.
ON/OFF TIMER AND CURRENT TIME
7
BUTTONS
If you set the ON and OFF times, the unit will automatically turn on and off at the set times. ( Refer to pp.15 -16 ) If you press the CLOCK button during Timer operation, you will see the current time for 5 seconds.
LR03(AM4)1.5V
LR03(AM4)1.5V
FAN SPEED SELECTING
5
RST TA
BUTTON
Press the button to select the desired fan speed of AUTO, LOW, MED or HIGH, and the indoor fan will operate at the selected fan speed. If you select “AUTO”, the fan speed will be controlled by the microcomputer of the unit.
HOUR/MINUTE SETTING BUTTONS
8
Adjust the current time (Refer Page 11) and the on/off times of timer operation with these buttons.
RESERVA TION AND C ANCEL BUTT ONS
9
Press the RESERV. button to reserve the ON/OFF Timer and press the CANCEL button to cancel the reserved on/off time. ( Refer to pp.15 -18 )
EVERYD AY TIMER BUTTON
10
Press the EVERYDAY button and the on/off time you have reserved will be repeated until cancelled. ( Refer to pp.15 -18 )
CURRENT TIME ADJUSTING BUTT ON
11
Press this button to adjust the current time. ( Refer to p.11 )
RESET BUTTON
12
Press this button when the remote control is not operating properly or after replacing batteries. ( Refer to p. 11 )
ADDRESS SWITCH
13
If you have two indoor units in the same room, you can link one remote control with one indoor unit, and link the other remote control with the other indoor unit. ( Refer to p.11 )
BEFORE OPERA TION
Remote Control Display
햳 햴
A
SWING
Indicates the selected temperature.
5
Indicates flap modes
6
AUTO
Automatic position
OWNER,S MANUAL - 10
A
Indicates the selected operating mode.
1
A
AUTOMATIC CHANGEOVER
COOL DRY FAN
Lights up when the signal from the remote
2
control is transmitted. A receiving beep is heard from the unit.
Lights up when the batteries must be
3
replaced with new ones. When this mark appears, replace the batteries within a week.
HEAT
User selected position
SWING
Indicates the reserved status of SLEEP timer or
7
EVERYDAY timer.
Indicates the reservation time of ON timer and
8
OFF timer or the current time.
Indicates the selected fan speed.
9
Swing up and down
A
AUTO LOW MED HIGH
Lights up when the unit is operating.
4
BEFORE OPERA TION
REMOTE CONTROL PREPARA TION
Replacing Batteries
1 2 3
Remove the cover of the battery compartment at the back of the remote control by sliding it out in the direction of the arrow.
RST TA
LR03(AM4)1.5V
LR03(AM4)1.5V
Remove the used batteries and insert new batteries. The remote control uses two alkaline batteries. (1.5V, LR03x2)
RST TA
LR03(AM4)1.5V LR03(AM4)1.5V
NOTE
OWNER,S MANUAL -11
Press the RST button with a sharp object to reset the remote control .
ON/OFF
SLEEP
TEMP.
MODE FAN FLAP
CLOCK EVERYDAY HOUR MINUTE
TIMER
RESERV
.
CANCEL
ON OFF
RST TA
Do not fit use the used batteries or batteries of a different type. Such use may cause the unit to malfunction.
Changing batteries should be done after turning off the unit.
The average battery life during normal use is approximately one year .
When the air conditioner does not operate normally after replacing the batteries, remove the batteries, refit
them and repress the RST button after 5 seconds.
TA/RST button may locate back side near battery compartment for some models.
Setting Current Time
Press the T A button with a sharp
4 5 6
object and the current time indication symbol flashes. In the beginning, 6:00A.M. will flash.
SLEEP
ON/OFF
TEMP.
MODE FAN FLAP
CLOCK EVERYDAY HOUR MINUTE
TIMER
RESERV
.
CANCEL
ON OFF
RST TA
Set the current time with the hour and the minute buttons while the current time indication flashes.
SLEEP
ON/OFF
TEMP
.
MODE FAN FLAP
CLOCK EVERYDAY
HOUR MINUTE
TIMER
RESERV
.
CANCEL
ON OFF
RST TA
Press the T A button again. The flashing will stop and the current time will be set.
SLEEP
ON/OFF
TEMP.
MODE FAN FLAP
CLOCK EVERYDAY HOUR MINUTE
TIMER
RESERV
.
CANCEL
ON OFF
RST TA
Matching Address between Indoor Unit and Remote Control
When two units are used in the same room, you can match the address of the remote control to that of the unit.
1
Remove the lid of the battery case. Assign the address switch of one remote control as B.
2
Press the RST button with a sharp object. Turn off the unit and pull out the power plug. Remove the front panel, T erminal block cover, and Frame grille.
3
Pull out the PCB. Assign the address switch of one indoor unit as B.
NOTE
This function must only be performed by qualified service personnel.
BEFORE OPERA TION
Signal Receiving
The remote control will only function when operated within 5 meters of the unit.
You can hear a beeping sound from the unit in the following cases, which indicates that the signal is received.
5m maximum
CAUTION
OWNER,S MANUAL - 12
The air conditioner will not operate if curtains,
doors or other materials block the signals from the remote control to the unit.
Avoid spilling liquid onto the remote control
or dropping it. This can cause deformation, discoloration and malfunction.
If the infrared signal receiver on the unit is exposed to direct sunlight, the air conditioner may not work properly. Draw the curtains to avoid direct sunlight.
A mounting bracket for the remote control is supplied with the unit. Install the mounting bracket on the wall 30cm below the receiver of the unit.
OWNER,S MANUAL - 13
UNIT OPERA TION
AUTOMATIC OPERATION
Automatic operation means that the air conditioner operates automatically by selecting the COOL or HEA T mode and automatically changes the fan speed according to the indoor condition to keep the room temperature comfortable.
PROCEDURE
ON/OFF button
1
A
A
ON/OFF
MODE FAN FLAP
EVERYDAY
CLOCK
TIMER
ON OFF
RST TA
SLEEP
TEMP.
HOUR MINUTE
RESERV.
CANCEL
Press this button and the unit starts AUTO operation.
MODE button
2
If the unit is operating in another mode, press the MODE button to select AUTO.
TEMP. ( ) buttons
3
Set the desired temperature using the remote control buttons. At the start of the AUTO operation, the temperature is set at 25°c and it is functional within the total temperature range.
FLAP button
4
Press this button to control the desired air flow direction.
FAN SPEED button
5
Set the desired fan speed at start up, on AUTO.
ON/OFF button
6
Press this button again to stop operation.
NOTE
When the room temperature is between 21°c ~ 29°c.
- If the room temperature is lower 1°c or more than the set temperature : HEAT mode will operate
- If the room temperature is higher1°c or more than the set temperatur e : COOL mode will operate
When the room temperature is lower than 21°c or higher than 29°c, the operation mode is restricted regardless of the set temperature.
- If the room temperature is lower than 21°c then only the heating mode is allowed.
- If the room temperature is higher than 29°c then only the cooling mode is allowed.
The Auto operation is not suitable for the application to the computer room or some food/wine stock storage.
UNIT OPERA TION
MANUAL OPERATION
PROCEDURE
A
A
ON/OFF
SLEEP
TEMP.
OWNER,S MANUAL - 14
ON/OFF button
1
Press this button and the AUTO operation is indicated.
A receiving beep is heard.
The green UNIT on lamp of the indoor unit display illuminates.
MODE button
2
Press this button to select the desired operation mode. AUTO DRY COOL F AN HEAT
FAN SPEED button
3
Press this button to select the desired fan speed. AUTO LOW MED HIGH
TEMP.( ) button
4
Press these buttons to set the desired temperature.
MODE FAN FLAP
EVERYDAY
CLOCK
TIMER
ON OFF
RST TA
HOUR MINUTE
RESERV.
CANCEL
FLAP button
5
Press this button to control the desired air flow direction.
ON/OFF button
6
Press this button and AUTO operation is indicated.
A receiving beep is heard.
The UNIT ON lamp is extinguished.
DRY OPERATION
This operation eliminates moisture economically by operating the compressor, indoor and outdoor fan motor intermittently, so that the room temperature is maintained at the set temperature.
UNIT OPERA TION
TIMER OPERATION
ON Timer
PROCEDURE
ON TIMER button
1
Press this button. On start up, time is set at 6:00 A.M..
OWNER,S MANUAL - 15
A
A
ON/OFF
MODE FAN FLAP
EVERYDAY
CLOCK
TIMER
ON OFF
RST TA
SLEEP
TEMP.
HOUR MINUTE
RESERV.
CANCEL
HOUR, MINUTE buttons
2
Press these buttons to set the start-up time desired while the ON Timer symbol is flashing.
RESERV. button
3
Press this button when pointing the remote control towards the receiver of the indoor unit.
A receiving beep is heard.
TIMER lamp of the indoor unit illuminates.
MODE, FAN, FLAP, and TEMP. buttons
4
Set the desired operation mode with these buttons.
About ON Timer
When the ON Timer is set, the unit monitors the room temperature for 1hour before the set time to make sure the room condition is reached by the reserve time.
The actual on time of the unit is earlier that the reserved time by 0 to 40 minutes according to the difference between room temp. and set temp.
NOTE
The current time is not indicated during the reservation of ON/OFF Time.
When you want to know the current time, press the CLOCK button and you will see the current time for 5 seconds.
If you reserve the ON Timer during operation, the unit will operate continuously
UNIT OPERA TION
OFF Timer
OWNER,S MANUAL - 16
PROCEDURE
OFF TIMER button
1
A
A
Press this button. In the beginning, the time is set at 2:00 A.M. .
HOUR, MINUTE buttons
2
Press these buttons to set the stop time desired while the OFF Timer symbol is flashing.
ON/OFF
MODE FAN FLAP
EVERYDAY
CLOCK
TIMER
ON OFF
RST TA
SLEEP
TEMP.
HOUR MINUTE
RESERV.
CANCEL
RESERV. button
3
Press this button by pointing the remote control towards the receiver of the indoor unit.
A receiving beep is heard.
TIMER lamp of the indoor unit illuminates.
UNIT OPERA TION
Combination of ON, OFF and EVERYDAY Timer
PROCEDURE
For example when you want the operation to start at 5:30
P.M. and stop at 10:30 P.M..
1
2 3
Or when you want to stop the operation at 10:30 P.M. and start
again at 7:30A.M. with the same condition.
1
OWNER,S MANUAL - 17
Reserve the ON Timer at 5:30 P.M..
Reserve the OFF Timer at 10:30 P.M..
Set the operation mode as desired.
Reserve the OFF Timer at 10:30 P.M. during operation.
Reserve the ON Timer at 7:30 A.M..
2
Refer to pp.15 -16 for the setting method and refer to p.18 for the canceling method of the ON, OFF and EVERYDAY Timers.
In the ON and OFF Timer operation, the earlier setting compared to the current time will be applied first.
The EVERYDAY Timer can be selected in case of a combination of the ON and OFF Timer reservation or
ON and SLEEP Timer reservation.
You can change the ON/OFF reservation time where the EVERYDAY Timer reservation.
When you want to start operation at 5:30 P.M. and stop at 10:30 P. M. everyday with the same operating condition.
Reserve the ON Timer at 5:30 P.M..
1
Reserve the OFF Timer at 10:30 P.M..
2
Press the EVERYDAY button and RESERV. button.
3
NOTE
UNIT OPERA TION
Cancellation of ON, OFF and EVERYDAY Timer
A
A
OWNER,S MANUAL - 18
PROCEDURE
Press the ON TIMER button to cancel the ON Timer
1
or press OFF TIMER button to cancel the OFF Timer. To cancel the EVER YDAY Timer reservation, press the EVERYDAY , ON TIMER or OFF TIMER button.
Press the CANCEL button by pointing the remote
2
control towards the receiver of the indoor unit.
A receiving beep is heard.
TIMER lamp of the indoor unit lights off.
TEMP.
HOUR MINUTE
RESERV.
SLEEP
CANCEL
ON/OFF
MODE FAN FLAP
EVERYDAY
CLOCK
TIMER
ON OFF
RST TA
NOTE
If you cancel the ON Timer or OFF Timer reservation while EVERYDAY Timer is reserved, EVERYDA Y Timer will be automatically canceled.
When the electricity fails while EVERYDAY Timer is reserved, EVERYDAY Timer reservation will be canceled. Reserve the EVERYDAY Timer again after the electricity comes on.
The current time will not be indicated and the TIMER lamp of the indoor unit will be on if either the ON Timer or the OFF Timer is reserved.
UNIT OPERA TION
TIME (MIN.)
FOR COOLING OR DRY MODE
SET TIME
30 70 110 150
SET
TEMP.
°C
+0.5°C
+0.5°C
+0.5°C
+0.5°C
TIME (MIN.)
FOR HEATING MODE
SET TIME
90 150
SET
TEMP.
°C
–1°C
–1°C
–1°C
30
Sleep Timer
This function enables the user to automatically switch off the unit.
PROCEDURE
If you want to stop the operation after 3 hours from now. Press the SLEEP button 3 times
1
3:hr will be displayed and the signal will be flashing.
After 5 seconds, the stopping time will be displayed.
The unit operates in sleep mode for 3 hours and will
switch off at the end of the 3 hours.
T o change the reserved time or to cancel, press the SLEEP Button again. 1:hr 2:hr 3:hr 7:hr 9:hr Cancel
When the SLEEP Timer is set, the unit will control the
2
set temperature to avoid overcooling or overheating in operation. Set temperature is changed as shown below.
ON/OFF
A
A
SLEEP
TEMP.
OWNER,S MANUAL - 19
SLEEP
SLEEP
SLEEP
When the SLEEP timer is set, the luminosity of the unit lamps will be dimmed so as not to interrupt the sleep.
The SLEEP timer can be combined with the ON timer.( Refer to p.17 for combination )
NOTE
OWNER,S MANUAL - 20
UNIT OPERA TION
DISCHARGE AIR LOUVER CONTROL
Up and Down Control
The air discharge direction can be controlled to swing up and down and can be fixed at a preferred position or at automatic position by the remote control.
AUTO
SWING
If you select the Flap position using the FLAP button in the remote control, the flap in the unit will move to that position automatically. Once you select the position, the unit remembers that position and whenever you turn on the unit, the flap will be positioned to that position.
If you select SWING, the flap will swing up and down. In the COOL, DRY and FAN mode, the flap will swing in the cool range. In the HEA T mode, the flap will swing in the heat range.
If you select AUTO, the flap will position itself to the preset position according to the operation mode.
CLOSE
Fixed
COOL
HEAT
Swing Range
COOL
HEAT
Auto Position
NOTE
Always use the remote control to adjust the flap position, otherwise it may cause abnormal operation. Please turn off the unit and turn it on again when you manually adjust the flap out of range.
Left and Right Control
If you want to adjust the direction of the discharge air left or right, adjust the vertical louver with the handle after opening the flap.
HANDLE
NOTE
Please do not fix the flap at position 햲 for a long time, as this position minimizes air circulation resulting in uneven room temperature.
Avoid the discharge air being directed towards the occupants for a long period of time.
Do not adjust the flap by the hand during SWING operation because it may damage the air swing mechanism.
OWNER,S MANUAL - 21
UNIT OPERA TION
EMERGENCY AND TEST OPERATION
EMERGENCY TEST
Emergency Operation
When the remote control is lost, damaged or the battery is discharged, the EMERGENCY button can be used to run the unit.
Press the EMERGENCY button at the off mode condition.
- The unit operates automatically according to the room temperature by selecting either the cooling or the heating operation.
If you want to stop the emergency operation, push the EMERGENCY button again or operate the remote control.
The setting conditions of emergency operation are as follows:
- Operation mode : AUTO
- Preset temperature : 25°c
- Fan speed : AUTO
- Timer mode : Disable
- Discharge air direction : Set automatically according to operation mode. ( Refer to p. 20 )
Test Operation
This operation is used for checking after unit installation.
Press the TEST button.
Press the TEST button once more after checking to activate remote control. If there is any input
signal ( remote control signal or EMERGENCY button pressed ) during test operation, the TEST mode will change to the input signal mode.
The setting conditions of the test operation are as follows:
- Operation mode : COOL
- Fan speed : HIGH
- Timer mode : Disable
- Discharge air direction : SWING
OWNER,S MANUAL - 22
UNIT OPERA TION
AIR CLEANING OPERA TION
Information for filters
Filters Air filters Option 1 : Active carbon filter/Photo-catalyst filter Option 2 : Active carbon filter/Electrostatic filter
Air filters eliminate dust and lint
Optional Active carbon filter/Photo-catalyst filter effectively eliminates odor and cigarette smoke in the room air.
Optional Active carbon filter/Electrostatic filter is particularly effective in eliminating odor and micro scopic dust.
ACTIVE CARBON FILTER
(Black color, OPTIONAL)
Life time of filters
PHOTO-CA TALYST FIL TER (Blue color, OPTIONAL)
or ELECTROSTATIC FILTER (White color, OPTIONAL)
ST ANDARD AIR FILTER
The life of above filters varies according to the amount of cigarette smoke, room size and the operating time.
Air filters can be cleaned with a vacuum cleaner or rinsed under running water after using a month.
(Refer to CLEANING THE FILTERS AND FRONT PANEL,p.25.)
The life time of optional Active carbon filter is about 2 years and that of optional Electrostatic filter is about 3 months. These filters cannot be recycled.
The life time of optional Photo-catalyst filter is about 2 years. This filter can be washed under running water and can be refreshed by exposing under direct sun light. Exposed time is 6 hours after using 3 months. (Refer to CLEANING THE FILTERS AND FRONT PANEL,p.25)
OWNER,S MANUAL - 23
CARE AND MAINTENANCE
POINTS T O NO TE
Operating Condition
T emperature ranges suitable for unit operation are as follows. MODE INDOOR OUTDOOR
COOL 21 ~ 32°c 21 ~ 43°c HEA T Below 27°c Below 21°c DRY 17 ~ 32°c 12 ~ 43°c
When the unit operates above or below these conditions for a long time, system diagnostics may detect a
malfunction and the unit will not operate properly.
If the unit operates for a long time under abnormal situation of extremely high humidity, condensed water may
drip from the unit.
Time Delay
There will be time delay between compressor turning off and turning on. (Cool and Dry mode : 3minutes,
Heat mode : 3minutes for RAS-18LKH-A/RAS-18LAH-A, 5minutes for RAS-22LKH-A/RAS-22LAH-A)
When heating operation starts, hot air delivery might be delayed due to a warm up period.
Minimum Operation Time
In normal operation, once the compressor turned on, there is a minimum operation time of 3 minutes regardless of
ther mostat satisfaction.
Heating Features
When the unit starts in the heating mode, there will be a preheating period before the unit is ready to deliver
warm air.
• When the outdoor temperature is low, the heating capacity will be reduced. If the room air is not warm enough
during severe winter conditions, use additional heating devices.
Defrost Operation
In the heating mode, when the outdoor coil is frosted, the indoor fan and outdoor fan will turn off while the
compressor will turn on to remove the frost on the outdoor coil.
The defrost mode stops after 10 minutes or when the outdoor coil temperature is greater than 25°c.
When the power is off, the defrost operation is automatically conducted depending on frost
accumulation on the outdoor coil.
Auto Recovery
When the electricity fails while the unit is operating, the unit memorizes the operating condition, and it will
start operation automatically when the electricity is restored.
When you leave home during an electricity failure, please unplug the power cord, or the unit will automatically
restart in your absence.
OWNER,S MANUAL - 24
CARE AND MAINTENANCE
Frost Prevention of Indoor Unit
When the unit operates (on cooling) at a low ambient temperature, frost may appear on the indoor coil. When the indoor coil temperature is below 0°c, the microcomputer makes the compressor stop to protect the unit from frost.
Normal Operation
Any of the following can occur during normal operation:
A sound like a GURGLE can sometimes be heard during operation or when the unit stops.
- It is the sound of the refrigerant flowing through the unit.
Bad smells can come from the unit.
- Smells such as smoke or cosmetics can accumulate while room air circulates through the unit.
- Cleaning the filters will reduce this problem.
The outdoor fan does not rotate during heating operation.
- The unit is in defrost mode.
UNIT ON lamp on the indoor unit display flashes and no air comes from the unit.
- It indicates malfunction of the unit and the compressor will stop operating.
A creaking noise can sometimes be heard during operation or when the unit turns on.
- This is the sound of plastic expanding due to an abrupt temperature change.
CARE AND MAINTENANCE
CLEANING THE FILTERS AND FRONT PANEL
Cleaning the Air Filter
NOTE
T urn off the unit and pull out the power plug.
Clean the air filters once a month.
OWNER,S MANUAL - 25
Lift the front panel and pull the
1 2 3
air filters downward.
Clean the filters with a vacuum cleaner.
Refreshing the optional Photo-catalyst filter
Lift the front panel and pull the
1 2 3
optional Photo-catalyst filter downward.
Blow off the dust from the filter with fresh air or wash the filter under running water.
Rinse the filters under running water, and dry them completely, and then refit them correctly into their guides.
Expose under direct sun light for 6 hours and refit it correctly into its guide.
Washing the Front Panel
NOTE
T urn off the unit and pull out the power plug.
Clean the front panel if it becomes dirty and spotted.
Front panel is removable.
Lift the front panel up to the top
1 2 3
of the unit. Then separate the front panel from the unit.
Rinse the panel under running water, and dry it completely in a shaded area.
Refit it correctly. Installation procedure is reverse to the removal procedure.
CARE AND MAINTENANCE
;
CLEANING THE MAIN UNIT
OWNER,S MANUAL - 26
Use only a damp soapy towel.
Do not pour water onto the unit, and do not use
petrol, solvents or abrasive powder which may result in damage of the unit.
NOTE
When cleaning the unit, first turn it off and pull out the power plug.
AFTER-SEASON CARE
Clean the filters and refit them into the unit.
1 2
If the unit is to be switched off for an extended period, run the unit on FAN only for two hours to dry inside of the unit.
Clean the indoor and outdoor unit.
3
TROUBLESHOOTING
Trouble Check Points Action
Check that the power cord is plugged Insert the power cord into the wall outlet. into the wall outlet.
Has the circuit breaker tripped or has the Reset the circuit breaker or replace the fuse blown? fuse with the specified replacement fuse.
Unit does not operate
Has there been a power failure? Restart operation when power is resumed.
Does the UNIT ON” lamp flash on and off? Call your service representative.
Is the voltage too low? Confirm the available voltage.
Is the filter blocked with dust? Clean the air filter.
Has the temperature been set properly? Check and reset it if necessary.
OWNER,S MANUAL - 27
Cooling is abnormally low.
Heating is abnormally low.
Unit stops during operation.
If the above actions do not correct the operation, consult the dealer from whom you bought the unit.
Are the windows or doors open? Close the windows and doors.
Is anything obstructing the outdoor unit? Remove the obstruction.
Is the fan speed too low? Change the fan speed selection.
Is the operation mode FAN or AUTO?
Is the filter blocked with dust? Clean the air filter.
Has the temperature been set too low? Check and reset it if necessary.
Are the windows or doors open? Close the windows and doors.
Is anything obstructing the outdoor unit? Remove the obstruction.
Is the OFF timer operating? Restart the unit operation.
Has passed the set time of sleep timer? Restart the unit operation.
Change to cooling operation or reset the temperature.
P/N:42QG8Q5404C