Thank you for purchasing this TOSHIBA Air Conditioner. Please read this owner’s manual carefully before using
your Air Conditioner.
Avant tout, merci d’avoir porté votre choix sur un climatiseur TOSHIBA. Veuillez lire attentivement ce mode d’emploi
avant de mettre en service le climatiseur.
Wir danken Ihnen für den Kauf dieses TOSHIBA-Klimageräts. Lesen Sie die Bedienungsanleitung sorgfältig durch,
bevor Sie das Gerät in Betrieb nehmen.
Tack för ditt inköp av denna TOSHIBA luftkonditionering. Läs den här bruksanvisningen noga innan du använder
din luftkonditionering.
Благодарим Вас за покупку этого кондиционера фирмы TOSHIBA. Перед использованием Вашего
кондиционера прочитайте, пожалуйста, внимательно эту инструкцию для пользователя.
Kiitämme tämän TOSHIBA-ilmastointilaitteen ostamisesta. Lue tämä omistajan opas huolellisesti ennen
ilmastointilaitteen käyttöä.
Tak fordi du købte dette TOSHIBA airconditionanlæg. Læs denne brugermanual omhyggeligt igennem, inden du
anvender dit airconditionanlæg.
Takk for at du kjøpte dette klimaanlegget fra TOSHIBA. Vi oppfordrer deg til å lese brukerhåndboken grundig før du
begynner å bruke klimaanlegget.
RAS-10SAVP-ND
RAS-13SAVP-ND
RAS-16SAVP-ND
RASseries_OwnersManual.book Page i Tuesday, January 9, 2007 2:53 PM
• DO NOT ATTEMPT TO INSTALL THIS UNIT BY YOURSELF. THIS UNIT REQUIRES A QUALIFIED
INSTALLER.
• DO NOT ATTEMPT TO REPAIR THE UNIT BY YOURSELF. THIS UNIT SHOULD BE
PROFESSIONALLY REPAIRED.
• OPENING OR REMOVING THE COVER WILL EXPOSE YOU TO DANGEROUS VOLTAGES.
• TURNING OFF THE POWER SUPPLY WILL NOT PREVENT POTENTIAL ELECTRIC SHOCK.
WARNING
INSTALLATION WARNINGS
• Be sure to ask a dealer or a store specialized in electric work to install the air conditioner.
• If the air conditioner is improperly installed by yourself, it can cause some problems such as water
leaks, electric shock, fire, and so on.
• Be sure to always ground the air conditioner.
• Do not connect the ground wire to gas pipes, water pipes, lightning rods or ground wires of
telephones. If the air conditioner is improperly grounded, it can cause an electric shock.
CAUTION
TO DISCONNECT THE APPLIANCE FROM THE MAIN POWER SUPPLY
A switch or circuit breaker that can disconnect all poles must be included in the fixed wiring. Be
sure to use an approved circuit breaker or switch.
OPERATION WARNINGS
• Avoid cooling the room too strongly or exposing yourself to cool wind for a long time because it can
be detrimental to your health.
• Never insert fingers or sticks into the air outlet and air inlet to avoid getting injured and damaging the
machine because there are fans running at a high speed inside both the air inlet and air outlet.
• When you notice something unusual with the air conditioner (such as a burning smell or weak cooling
power), immediately turn off the main switch and the circuit breaker from the main power supply to
stop the air conditioner, and contact the dealer.
• If the air conditioner is operated continuously when something is wrong, it can cause machine failure,
electric shock, fire, and so on.
• Do not spill water or other liquid on the indoor unit. If the unit is wet, it can cause an electric shock.
MOVEMENT AND REPAIR WARNINGS
• Do not attempt to move or repair the unit by yourself.
• Do not disassemble the unit. As there is high voltage inside the unit, you may receive an electric
shock.
• Always ask the dealer to move the air conditioner for re-installing it in another place. If it is improperly
installed, it can cause electric shock or fire.
• Whenever the air conditioner needs repairs, request repairs from the dealer.
If the air conditioner is repaired improperly it can cause an electric shock or fire.
• Securely lay the drain hose for the best draining results.
• Incorrect drainage can cause flooding in the house and furniture to get wet.
• Be sure to connect the air conditioner to a dedicated power supply having the rated voltage.
Otherwise, the unit can break down or cause a fire.
• Do not install the unit in a place where inflammable gas can leak. A fire can result if inflammable gas
accumulates around the unit.
• The indoor unit shall be installed so that the top of the indoor unit is at least 2 m in height. Also, avoid
putting anything on the top of the indoor unit.
OPERATION CAUTIONS
• Carefully read this manual before starting the air conditioner. The manual includes a lot of important
information for daily operation.
• Do not use this air conditioner for other purposes such as preserving food, precision instruments, art
objects, breeding animals, or growing potted plants.
• Do not install this air conditioner in a special-purpose room such as a ship or any kind of vehicle.
Doing so could harm machine performance.
• Avoid exposing potted plants and animals to wind from the air conditioner because it harms their
health and growth.
• When the air conditioner is operated in close proximity to a combustion device, pay careful attention
to ventilation and let fresh air into the room.
Poor ventilation can cause an oxygen shortage.
• When the air conditioner is used in a closed room, pay careful attention to the ventilation of the room.
Poor ventilation can cause an oxygen shortage.
• Do not touch the operation buttons with wet hands. Doing so could cause an electric shock.
• Do not place any combustion device in a place where it is directly exposed to wind from the air
conditioner. Doing so could cause incomplete combustion.
• When the air conditioner is not to be used for an extended period of time, turn off the main switch or
the circuit breaker for added safety. Disconnecting from the power supply protects the unit from
lightning and power surges.
• Do not put a container with water such as a vase on the unit because water can enter into the unit
and cause an electric shock due to deterioration in the electric insulation.
• Check the concrete blocks underneath the outdoor unit occasionally. If the base is left damaged or
deteriorated, the unit can topple over and could possibly cause an injury.
• Do not wash the unit with water. This could cause an electric shock.
• Do not use alcohol, benzene, thinner, glass cleaner, polishing powder or other solvent for cleaning
the unit because they can deteriorate and damage the air conditioner.
• Before cleaning the unit, be sure to turn off the main switch or circuit breaker to prevent injuries from
the electric fan running inside.
• For details of the cleaning method, refer to “USUAL MAINTENANCE” and “SPECIAL
MAINTENANCE” on pages 20 to 23.
• Do not put anything on or step on the indoor unit and outdoor unit. If you do so, it can topple over and
cause an injury.
• To allow the air conditioner to operate at maximum performance, operate within the operating
temperature range specified in the instructions. Failure to do so can cause a malfunction, break
down, or water to leak from the unit.
• It is recommended that maintenance be performed by a specialist when the unit has been operated
for a long time.
NAMES AND FUNCTIONS OF INDICATORS AND CONTROLS
ON INDOOR UNIT
Display panel
The operating states are shown below.
a RESET button
b FILTER indicator (Orange)
c TIMER indicator (Yellow)
d PURE indicator (Blue)
e OPERATION indicator (Green)
The operation indicators flash rapidly (5 times per second)
when a safety protection feature is activated.
f S.CLEAN indicator (Green)
When the unit shuts down after having operated for 10 or more
minutes in the cooling or dry mode, the cleaning operation is
started automatically, and the S.CLEAN indicator turns on.
RESET button
The RESET button has the following two functions.
• Reset function
Use when the FILTER indicator (orange) is on. () see page 21.)
• Temporary operation function
Use when you misplace or lose the remote controller, or when its
batteries are used up. () see page 19.)
Press the button to start operation. (A receiving beep is
heard.) Press the button again to stop operation. (A
receiving beep is heard.)
If no receiving sound is heard from the indoor unit, press
the button again.
c Mode select button (MODE)
Press this button to select a mode. Each time you press
the button, the modes cycle in order from A: Auto
changeover control, : COOL, : DRY, : HEAT and
back to A.
(A receiving beep is heard.)
d Temperature button ( )
.. The temperature setting is raised to 30°C.
... The temperature setting is lowered to 17°C.
(A receiving beep is heard.)
e Fan speed button (FAN)
Press this button to select the fan speed. When you select
AUTO, the fan speed is automatically adjusted according to
the room temperature. You can also manually select the
desired fan speed from five available settings.
(LOW, LOW+, MED, MED+,
HIGH) (A receiving beep is heard.)
f Auto louver button (SWING)
Press this button to swing the louver. (A receiving beep is
heard.)
Press the button again to stop the louver from swinging. (A
receiving beep is heard.) () see page 16.)
g Set louver button (FIX)
Press this button to adjust the air flow direction. (A
receiving beep is heard.) () see page 16.)
h ON timer button (ON)
Use this button to change the clock and ON timer times.
To move up the time, press of the ON button.
To move down the time, press of the ON button.
i OFF timer button (OFF)
Use this button to change the OFF timer times.
To move up the time, press of the OFF button.
To move down the time, press of the OFF button.
j Reserve button (SET)
Press this button to store the time settings. (A receiving
beep is heard.)
k Cancel button (CLR)
Press this button to cancel the ON timer and OFF timer. (A
receiving beep is heard.)
l High power button (Hi POWER)
Press this button to start high power operation. () see
page 18.)
m Memory button (MEMO)
Press this button to ready for storing the settings.
Hold down the button for 3 seconds or more to store the
setting indicated on the remote controller and until the
mark is displayed. () see page 15.)
TEMP
ON
ON
OFF
OFF
n Automatic operation button (AUTO)
Press this button to operate the air conditioner
automatically.
(A receiving beep is heard.) () see page 18.)
o SLEEP MODE button
Press this button to start sleep mode. () see page 18.)
p MY COMFORT button
Press this button to operate the air conditioner according to
the settings stored using the MEMO button. () see
page 15.)
q PURE button (PURE)
Press this button to start the electrical air purifying
operation.
Press the button again to stop operation.
r Off timer button (OFF)
Press this button to start the OFF timer operation.
You can select the OFF timer time from among four
settings (1, 3, 5 or 9 hours).
s 8°C operation button (8°C)
Press this button to start the 8°C set temperature heating
operation. ()
NAMES AND FUNCTIONS OF INDICATORS ON REMOTE
CONTROLLER
Display
All indicators, except for the clock time indicator, are displayed by pressing the button.
a Transmission mark
This transmission mark ( ) indicates when the remote controller transmits signals to the indoor unit.
b Mode indicator
Indicates the current operation mode.
(AUTO: Automatic control, A: Auto changeover control, : COOL, : DRY,
:HEAT)
c Temperature indicator
Indicates the temperature setting (17°C to 30°C).
d PURE indicator
Shows that the electrical air purifying operation is in progress.
e FAN speed indicator
Indicates the selected fan speed. AUTO or one of five fan speed levels (LOW,
LOW+, MED, MED+, HIGH) can be shown.
Indicates AUTO when the operating mode is either AUTO or : DRY.
f TIMER and clock time indicator
The time setting for timer operation or the clock time is indicated.
The current time is always indicated except during TIMER operation.
g Hi POWER indicator
Indicates when Hi POWER operation starts.
Press the Hi POWER button to start and press it again to stop operation.
h(MEMORY) indicator
Flashes for 3 seconds when the MEMO button is pressed during operation.
The mark is shown when holding down the button for 3 seconds or more while
the mark is flashing.
Press another button to turn off the mark.
i SLEEP MODE indicator
Indicates when the SLEEP MODE is activated.
Press the SLEEP MODE button to start and press it again to stop operation.
j A. B change indicator remote controller
• When the remote controller switching function is set, “B” appears in the remote
controller display. (When the remote controller setting is “A”, there is no
indication at this position.)
Remote controller switching function
• If two indoor units are installed in the same room or adjoining rooms, both units may start and stop at the same time when
the remote controller is operated. This can be prevented by setting the switching function so that each indoor unit is
operated only by the corresponding remote controller.
• To use the remote controller switching function, contact the air conditioner dealer or the installation company.
cabhjd
gi
• In the illustration, all indicators are shown
for purposes of explanation. During
operation, only the relevant indicators are
shown on the remote controller.
• To replace the batteries, use two new batteries (AAA type).
• The batteries will last about one year under normal usage.
• Replace the batteries if there is no receiving beep from the indoor unit or when the air conditioner cannot be operated using the
remote controller.
• To avoid malfunctions due to battery leakage, remove the batteries when not using the remote controller for over one month.
• Slide off the cover while pressing the sides.
• Battery replacement
Be careful not to reverse the (+) position and the (–) position.
Setting the clock
Before you start operating the air conditioner, set the clock of the remote controller using
the procedures given in this section. The clock panel on the remote controller will
indicate the time regardless of whether the air conditioner is in use or not.
Initial setting
When batteries are inserted in the remote controller, the clock panel displays AM 0:00
and flashes.
a ON button
ON
Press the ON button to set the current time.
ON
Each press of the ON button changes the time in one minute increments.
Holding down the ON button changes the time in ten minute increments.
b SET button
SET
Press the SET button.
SET
The current time is displayed and the clock starts.
Adjusting the clock
a CLOCK button
Press the CLOCK button.
The clock time indicator flashes.
b ON button
c SET button
ON
Press the ON button to set the current time.
ON
Each press of the ON button changes the time in
one minute increments.
Holding down the ON button changes the time in ten
minute increments.
SET
Press the SET button.
SET
The current time is displayed and the clock starts.
Check that the air filter and the plasma pure filter are correctly installed
• Press the plasma pure filter until the projections on both sides are fully inserted into the
holders (tabs). If the installation is not correct, the FILTER indicator (orange) may come
on.
Projections
USING THE REMOTE CONTROLLER
CAUTION
• The air conditioner will not operate if curtains, doors or other objects block the signals from the remote controller to the indoor
unit.
• Be careful that liquids do not spill onto the remote controller.
• Do not expose the remote controller to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly.
Use curtains to prevent sunlight from reaching the receiver.
• Signals may not be properly received, if the room using the air conditioner has fluorescent lighting with electronic starters. If
you plan to use fluorescent lamps, consult with your local dealer.
• If other electrical appliances are activated by the remote controller, move these appliances or consult with your local dealer.
Location of the remote controller
• Keep the remote controller where its signals can reach the receiver of the indoor
unit (a distance of up to 7 m is allowed).
• When you select timer operation, the remote controller automatically transmits a
signal to the indoor unit at the specified time.
If you keep the remote controller in a location where proper signal transmission is
blocked, a time lag of up to 15 minutes may occur.
Remote controller holder
Installing the remote controller holder
• Before you actually install the remote controller holder on a wall or pillar, check
whether the remote controller signals can be received by the indoor unit.
Mounting and removing the remote controller
• To mount the remote controller, hold it parallel to the remote controller holder and
push it in fully. To remove the remote controller, slide the remote controller
upwards and out from the holder.
When you set the air conditioner to AUTO mode, it automatically selects cooling, heating, or fan only operation depending on the room
temperature. () see page 18.)
The fan speed and louver are also automatically controlled.
Start
a button
Press this button to start the air conditioner.
b AUTO button (AUTO)
Press AUTO button.
c Temperature button ( )
Set the desired temperature.
• The OPERATION indicator (green) on the display panel of the indoor unit lights. The
operating mode is selected according to the room temperature and operation starts
after approximately 3 minutes.
• If the AUTO mode is uncomfortable, you can select the desired conditions manually.
The fan speed and louver position can be changed, and MODE is also changed from
AUTO to A when the fan speed or louver position is changed.
The fan speed indicator is also shown.
Stop
button
Press this button again to stop the air conditioner.
TEMP
b
c
a
AUTOMATIC OPERATION (AUTO CHANGEOVER)
When you set the air conditioner to A mode or switch over from AUTO operation because of a change in settings, the air conditioner
automatically selects cooling, heating, or fan only operation depending on the room temperature. () see page 18.)
Start
a button
Press this button to start the air conditioner.
b Mode select button (MODE)
Select A.
c Temperature button ( )
Set the desired temperature.
d Fan speed button (FAN)
Select one of “AUTO” LOW, LOW+, MED, MED+,
HIGH.
• The OPERATION indicator (green) on the display panel of the indoor unit lights. The
operating mode is selected according to the room temperature and operation starts
after approximately 3 minutes.
• The temperature, fan speed and louver position can be changed. You can select the
desired conditions manually.
Stop
button
Press this button again to stop the air conditioner.
Press this button to start the 8°C set temperature heating operation.
The air conditioner controls the room temperature to about 8°C.
The room temperature may deviate slightly from 8°C depending on the size of the room
and the installation condition of the unit.
Starting the 8°C heating operation while the air conditioner is stopped
Start
a 8°C button
Press this button to start the 8°C set temperature heating operation.
• The OPERATION indicator (green) on the display panel of the indoor unit turns on.
Operation starts after approximately 3 minutes.
Stop
button
Press this button to stop the air conditioner.
If the 8°C heating operation starts while the air conditioner is stopped, press the 8°C button again to stop the operation.
Starting the 8°C heating operation while the air conditioner is operating
Start
a 8°C button
Press this button to change to the 8°C set temperature heating operation.
a
• If the air conditioner performs a cooling (including automatic cooling) or dry operation, it stops and the 8°C set temperature heating
operation starts after approximately 3 minutes. If the air conditioner performs a heating operation, it changes immediately to the 8°C
heating operation.
• If the air conditioner performs a PURE operation, it performs both the pure operation and 8°C heating.
Stop
button
Press this button to stop the air conditioner.
If the 8°C heating operation starts while the air conditioner is operating, press the 8°C button again to return to the previous operating
condition.
Check the operating condition on the screen of the remote control.
When a heating operation starts from 8°C heating, it can take approximately 5 minutes for the warm air to start blowing.
CAUTION
The heating performance could worsen if the louver direction is too high during 8°C heating operation.
NOTE
• The fan speed at the start of 8°C heating is operated with AUTO.
• If a timer operation is set to before the 8°C heating operation, the timer operation setting is cancelled. Timer operation
settings cannot be made during 8°C heating operation.
• Settings for SWING (louver swing), FIX (louver position), FAN (fan speed) and PURE (pure operation) can be changed
during 8°C heating operation. Setting changes cannot be made with other buttons.
• The temperature of the blown air is lower than during normal heating operation.
• The PURE indicator (blue) on the display panel of the indoor unit turns on.
INFORMATIONINFORMATION
• During PURE operation, a small amount of ozone is produced, and you might notice the smell.
• When the air flow is automatic, it changes between LOW and MED+.
LOW operation is performed when the indoor air becomes clean. During operation, the position of the vertical air flow louvers may
change if the room temperature is low.
• Opening the air inlet grille during PURE operation sometimes turns on the FILTER indicator (orange).
In this case, stop PURE operation (stop the air conditioner if it is also operating), and then close the air inlet grille.
• The FILTER indicator (orange) turns on after PURE operation is performed for about 1000 hours.
When the indicator turns on, clean the plasma pure filter. () see page 22.)
• The Hi POWER (high power operation) mode automatically controls room temperature,
air flow and the operation mode so that the room is quickly cooled in summer and
warmed in winter. () see page 18.)
Setting Hi POWER mode
a Hi POWER button
Press the Hi POWER button. The Hi POWER mark on the remote controller is
shown.
Canceling Hi POWER mode
a Hi POWER button
Press the Hi POWER button once again.
The Hi POWER mark on the remote controller turns off.
CAUTION
The Hi POWER mode cannot be activated during DRY operation.
1, 3, 5, 9H OFF TIMER
The air conditioner stops after operating for the set time (1, 3, 5 or 9
hours).
a OFF button
Press the OFF button (during operation).
• There is a short beep and the timer indicator comes on. The time at which the air
conditioner will stop is indicated on the remote controller display (1H: about 1
hour after the current time).
• Press the button again while 1H is displayed (about 3 seconds) to change to the
3H indicator, press again to change to the 5H indicator, and press again to
change to the 9H indicator.
• After selecting the time you want, do not press this button again. (When the 1H,
3H, etc. indicator goes off the timer is set.)
b CLR button
Press the CLR button to cancel the timer.
• The timer is canceled but the air conditioner continues to operate.
• The 1, 3, 5 or 9H OFF timer operation is also canceled if the OFF button is
pressed after making a setting.
.
INFORMATIONINFORMATION
• Cleaning operation starts when the time of the 1, 3, 5 or 9H OFF timer is reached.
(Cleaning operation is not performed during heating operation or the PURE
operation.)
• When using in combination with the ON timer, first set the 1, 3, 5 or 9H OFF timer
and then set the ON timer.
• If the OFF button is pressed while the ON (OFF) timer has been set, the ON (OFF)
timer is canceled and only the 1, 3, 5 or 9H OFF timer is set.
Press the ON button. Set the timer to the desired time.
ON
Each time the ON button is pressed, the time changes in ten minute increments.
Holding down the ON button changes the time in one hour increments.
b SET button
SET
Press the SET button to set the timer.
SET
The timer time is displayed, and the timer starts.
c CLR button
CLR
Press the CLR button to cancel the timer setting.
CLR
Setting OFF Timer
a OFF button
OFF
Press the OFF button.
OFF
Set the timer to the desired time.
Each time the OFF button is pressed, the time changes in ten minute increments.
Holding down the OFF button changes the time in one hour increments.
b SET button
SET
Press the SET button to set the timer.
SET
The timer time is displayed, and the timer starts.
c CLR button
.
CLR
Press the CLR button to cancel the timer setting.
CLR
b
c
a
CAUTION
• When you select timer operation, the remote controller automatically transmits the timer signal to the indoor unit at the
specified time. Therefore, keep the remote controller in a location where it can transmit the signal to the indoor unit
properly.
• If you do not press the SET button within 30 seconds after setting the time, the setting will be cancelled.
Once you select timer operation mode, the settings are saved in the remote controller.
Thereafter, the air conditioner will start operating under the same conditions as you pressed the or button on the remote
controller.
You cannot set the timer when the clock display is flashing.
Follow the instructions in the section “Setting the clock” on page 6 to set the clock, and then set the timer.
Combined timer (Setting the ON and OFF timers simultaneously)
OFF timer —> ON timer
(Operation —> Stop —> Operation)
This feature is useful when you want to stop the air conditioner after you go to sleep, and start it again in the morning when you wake
up or you return home.
Example:
To stop the air conditioner and start it again next morning
Setting combined TIMER
(1) Press the OFF button to set the OFF timer.
(2) Press the ON button to set the ON timer.
(3) Press the SET button.
OFF
ON
SET
Operation
Stop
Operation again
ON timer —> OFF timer
(Stop —> Operation —> Stop)
You can use this setting to start the air conditioner when you wake up and stop it when you leave the house.
Example:
To start the air conditioner the next morning and stop it
Setting combined TIMER
(1) Press the ON button to set the ON timer.
(2) Press the OFF button to set the OFF timer.
(3) Press the SET button.
ON
OFF
SET
• The ON or OFF timer function that is closer to the current time is
activated first.
• If the same time is set for both ON and OFF timers, no timer
operation is performed. Also, the air conditioner may stop
operating.
Stop
CAUTION
Approximately 3 seconds later, the remote controller will
transmit the signal to the indoor unit and a receiving beep
will sound from the indoor unit after you press the
SET
SET button.
Operation
Daily combined timer (setting the ON and OFF timers simultaneously and activating every day)
This feature is useful when you want to use the combined timers at the same time every day.
Setting combined TIMER
(1) Press the ON button to set the ON timer.
(2) Press the OFF button to set the OFF timer.
(3) Press the SET button.
ON
OFF
SET
(4) After step (3), an arrow mark ( or ) flashes for about 3 seconds. Press the
SET
SET button during this flashing.
• Both arrows ( , ) are shown while the daily timer is activated.
Cancelling timer operation
Press the CLR button.
CLR
Clock display
During TIMER operation (ON-OFF, OFF-ON, OFF timer), the clock time indicator is not
shown so the setting time can be displayed. To view the current time, press the SET
button briefly and the current time will be displayed for about 3 seconds.
Use the MEMO button to store a frequently used operation setting for convenience.
Start the air conditioner in the operation mode that you want the remote controller to
store.
Press the button as shown below while the air conditioner is operating.
a MEMO button
Press this button briefly to ready for storing the setting.
All the icons currently shown flash, except for the clock time indicator and mode
indicator.
b MEMO button
Hold down the MEMO button for 3 seconds or more while the indicator flashes.
The mark is shown and the setting is stored.
• If you do not press the MEMO button within 3 seconds or if you press another button,
the MEMORY setting is cancelled.
• Operation modes which can be stored with the MEMO button are MODE, Temperature,
FAN, TIMER and Hi POWER.
• Adjust the air flow direction properly. Failure to do so could cause discomfort
and make an uneven room temperature distribution.
• Adjust the vertical air flow using the remote controller.
• Adjust the horizontal air flow manually.
Adjusting the vertical air flow
The air conditioner automatically adjusts the vertical air flow direction according
to the operating conditions when AUTO or A mode is selected.
To set a selected air flow direction
Use this function when the air conditioner is operating.
a FIX button
Hold down or briefly press the FIX button on the remote controller to move
the louver in the desired direction.
• Change the vertical air flow louver direction within the range indicated.
• In subsequent operations, the vertical air flow is automatically set to the
direction that you set the louver using the FIX button.
To automatically swing the air flow direction
Perform this function when the air conditioner is operating.
a SWING button
Press the SWING button on the remote controller.
• To stop the function, press the SWING button.
• To change the swing direction, press the FIX button.
a
CAUTION
• The FIX and SWING buttons will be disabled when the air conditioner is not
operating (including when ON TIMER is set).
• Do not operate the air conditioner for an extended period of time with the air
flow direction set downward during the cooling or dry operation. Otherwise,
condensation may occur on the surface of the vertical air flow louver and
cause water dripping.
• Do not move the vertical air flow louver manually. Always use the FIX button.
If you move the louver manually, it may malfunction during operation.
If the louver malfunctions, stop the air conditioner once, and restart.
• When the air conditioner is started immediately after it was stopped, the
vertical air flow louver might not move for about 10 seconds.
Adjusting the horizontal air flow
Preparation:
• Grasp the lever on the horizontal air flow louver and move them to adjust the air
flow direction as required.
• You can adjust the air flow at the left and right locations of the grilles.
This air conditioner is equipped with an automatic restarting function which allows the air conditioner to resume without the use of the
remote controller under the operating settings in the event of a power shutdown. Operation resumes without warning 3 minutes after
power is restored.
INFORMATIONINFORMATION
The AUTO RESTART OPERATION is not set to work at factory shipment, and so it is necessary to set it to this function if
required.
HOW TO SET AUTO RESTART
To set the auto restart function, proceed as follows:
The power supply to the unit must be on. The function will not be set if the power is off.
To enable the auto restart function, hold down the RESET button for 3 seconds.
The air conditioner receives the setting and beeps 3 times. The system now restarts
automatically. The auto restart setting is activated.
(1) When the air conditioner is in stand-by (not running).
Hold down the RESET button for 3 seconds or more.
• The air conditioner starts to operate. The green indicator turns on.
• After about 3 seconds, the air conditioner beeps 3 times.
The green indicator flashes for 5 seconds.
• The air conditioner is operating.
If the air conditioner is not required to run at this time, push the RESET button
again or use the remote controller to stop the air conditioner.
(2) When the air conditioner is operating.
Hold down the RESET button for 3 seconds or more.
• The air conditioner stops operating. The green indicator turns off.
• 3 seconds after pushing the button, the air conditioner beeps 3 times.
The green indicator flashes for 5 seconds.
• The air conditioner stops.
If you do not need the air conditioner to stop at this time, use the remote controller to restart the air conditioner. During the
subsequent operation, the green indicator is turned on.
• The auto restart operation will not accept a command if timer operation with the remote controller is activated.
• After restarting the air conditioner by the AUTO RESTART OPERATION, the louver swing (AUTO) operation resumes.
To cancel the auto restart operation, proceed as follows:
Repeat the setting procedure. The air conditioner receives the setting and beeps 3 times.
The air conditioner now needs to be manually restarted with the remote controller after the main supply is turned off.
The auto restart setting is cancelled.
(1) When the air conditioner is in stand-by (not running).
Hold down the RESET button for 3 seconds or more.
• The air conditioner starts to operate.
The green indicator will turn on.
• After about 3 seconds, the air conditioner beeps 3 times.
• The air conditioner is operating.
If the air conditioner is not required to run at this time, push the RESET button
again or use remote controller to stop the air conditioner.
(2) When the air conditioner is operating.
Hold down the RESET button for 3 seconds or more.
• The air conditioner stops operating.
The green indicator is turned off.
• After about 3 seconds, the air conditioner beeps 3 times.
• The air conditioner stops.
If you do not need the air conditioner to stop at this time, use the remote controller
to restart the air conditioner.
During subsequent operation, the green indicator is turned on.
As shown in Figure 1, Automatic Operation mode selects the operation based on the room temperature data (Ta) when operation
begins.
Room temperature when operation begins
or when selected again
Room temperature
Setting temperature+1
Setting temperature
Setting temperature–1
Figure 1
The operation mode is selected again after the compressor has remained stopped for 15 minutes.
Cooling operation
Fan only operation
Heating operation
Hi POWER operation
When you press the Hi POWER button during cooling, heating or A operation, the air conditioner starts the following operation.
• Cooling operation
The cooling operation is performed at 1°C lower than the temperature setting.
The fan speed is also set to high*.
* The noise level raises, according to the fan speed.
• Heating operation
The heating operation is performed at 2°C higher than the temperature setting.
The fan speed is automatically switched according to the operating condition.
SLEEP MODE operation
The air conditioner automatically controls the room temperature, air flow and noise level, to prevent overcooling in summer and
maintain a warm and comfortable room in winter.
INFORMATIONINFORMATION
• The power and noise level are reduced during sleep mode, so the room may not be cooled (or heated) sufficiently if the mode
is used for a long period of time.
• The sleep mode cannot be used during dry operation or PURE operation (independent operation).
(PURE operation (independent operation) is when the PURE button is pressed while the air conditioner is stopped to perform
PURE operation by itself. The air conditioner does not operate at this time.)
• If the FAN button is pressed during sleep mode, the sleep mode is canceled.
• Sleep mode is not a timer operation.
Dry operation ()
The dry mode automatically selects the cooling dry operation based on the difference between the temperature setting and the actual
room temperature.
The fan speed indicator shows AUTO, and low speed is used.
This function is used to operate the unit temporarily in case you misplace the remote
I cannot find
the remote
controller
controller or the batteries are used up.
• Push the RESET button to start the automatic operation (AUTO).
• While the temporary operation is activated, the remote controller operation is disabled.
• Hold down the button for 10 seconds to start the cooling operation.
A temporary
operation feature is
provided!
CLEANING OPERATION
Cleaning operation
This function is used to dry the inside of the air conditioner to reduce the growth of mold, etc. inside the air conditioner.
• When the unit shuts down after having operated for 10 or more minutes in the cooling or dry mode, the cleaning operation is started
automatically, and the S.CLEAN indicator on the unit’s display panel turns on.
Cleaning operation duration
• The cleaning operation lasts for 4 hours if the unit has been operating in the cooling or dry mode for 10 minutes or more.
About the cleaning operation
• The cleaning operation will not make the room cleaner or remove the mold and dust already inside the air conditioner.
• During operation, a small amount of frost may be visible: this is normal and does not indicate a malfunction.
• The vertical airflow louvers open slightly.
• If an ongoing cleaning operation is suspended, the effect of the cleaning will be compromised.
• To forcibly stop the cleaning operation, press the button twice during the cleaning operation.
Before you clean the air conditioner, be sure to turn off the circuit breaker or main power switch.
Cleaning of indoor unit and remote controller
CAUTION
• Use a dry cloth to wipe the indoor unit and remote controller.
• When the air conditioner is extremely dirty, use a cloth dipped in cold water to wipe the indoor
unit.
• Never use a damp cloth on the remote controller.
• Do not use a chemical-based duster for wiping or leave such materials on the unit for extended
periods of time. Doing so could damage or cause the surface of the unit to fade.
• Do not use benzine, thinner, polishing powder, or other solvents for cleaning.
These can cause the plastic surface to crack or deform.
When not using the unit for at least 1 month
(1) Perform fan operation for 3 to 4 hours to dry the inside of the unit.
• If a high temperature setting is used with cooling operation, fan operation is performed.
(2) Stop the air conditioner and turn off the circuit breaker.
(3) Clean the air filters.
(4) Remove the batteries from the remote controller.
Thinner
Cooling with
high
temperature
setting.
Wipe with a dry cloth
Check before operation
CAUTION
• Check that the air filters are installed.
• Check that the air outlet and inlet of the outdoor unit are not blocked.
Cleaning the air filter
Clean the air filters every 2 weeks.
The performance of the air conditioner will degrade if the air filters are covered with dust.
Clean the air filters as often as possible.
Preparation:
1. Turn off the air conditioner using the remote controller.
2. Open the air inlet grille.
1Open the air inlet grille.
Lift the air inlet grille up to the horizontal position.
2Grasp the left and right handles of the air filter and lift it up slightly, and then pull it downward to
take it out from the filter holder.
3Use a vacuum cleaner to remove the dust from the filters or wash them with water.
After washing the air filters, dry them in the shade.
4Insert the top section of the air filter so that its right and left edges fit on the
indoor unit and it is firmly set.
5Close the air inlet grille.
* If the FILTER indicator on the indoor unit is shown, press the RESET button
on the indoor unit to turn off the indicator.
Cleaning the air inlet grille
Preparation:
1. Turn off the air conditioner using the remote controller.
2. Open the air inlet grille.
Arms
1Remove the air inlet grille.
Hold the two sides of the air inlet grille and open upwards.
Remove the left (or right) arm by pushing it toward the outside and then pulling it
toward you.
2Wash it with water using a soft sponge or towel.
(Do not use a metallic scrubbing brush or other hard brushes.)
• Use of such hard objects will cause scratches on the surface of the grille and the
metal coating to peel off.
• If extremely dirty, clean the air inlet grille with a neutral kitchen detergent and
rinse it off with water.
3Wipe off the water from the air inlet grille and dry it.
4Fit the left and right arms of the air inlet grille to the shafts on the two sides of the
air conditioner and push them in completely.
5Pull the air inlet grille downward.
• Push the arrow locations (four) at the bottom of the air inlet grille to check that
the grille is completely closed.
NOTE
Cleaning and maintenance of the indoor/outdoor units are strongly recommended
for air conditioning systems which are used regularly.
Failure to clean the indoor/outdoor units regularly will result in poor cooling
performance, icing, water leakage and even premature compressor failure.
1. Turn off the air conditioner using the remote controller.
2. Turn off the power supply.
• Clean the plasma pure filter when the FILTER indicator (orange) turns on.
(This indicator turns on after PURE operation of about 1000 hours.)
• After cleaning is finished, push the RESET button on the indoor unit.
• Perform cleaning every six months or so.
• Even if the FILTER indicator does not turn on, clean the plasma pure filter whenever the unit makes a humming, clicking, or buzzing
sound. If the indicator turns on during the night, the air conditioner can still be used until the morning without a problem, but be sure
to perform cleaning as soon as possible.
1Open the air inlet grille.
Lift up the air inlet grille until it clicks into place.
2Grasp the left and right handles of the air filter and lift up slightly and then pull
downward to remove the filter from the filter holder.
3Take out the plasma pure filter.
• Grasp the handles, and then pull out as shown in a and b.
Checks after cleaning the plasma pure filter
1. Confirm the FILTER indicator does not turn on by activating PURE operation for
one hour or more.
<If it does not turn on, it is normal>
2. If the FILTER indicator turns on, recheck the following.
a) Fitting of the plasma pure filter
b) Fitting of the air inlet grille
And, reconfirm the FILTER indicator does not turn on by activating PURE operation for another one hour or more.
<If it does not turn on, it is normal>
3. In case the FILTER indicator does turn on, please call a service representative.
(1) Soak in hot water at 40 to 50°C for about 10 to 15 minutes. If the staining is particularly
severe, use a washing detergent compound (weak basic or neutral) at 10 to 15 times
the standard concentration.
(2) Rub up and down, and rub left and right. Also, rub the surface gently with a sponge.
(3) Rinse with running water.
(4) Shake thoroughly, and allow the unit to drain.
(If oil or smoke strains are particularly hard to remove, repeat steps (1) to (4) 2 or 3
times.)
(5) Dry thoroughly in the shade.
CAUTION
• Never use any products marked as “bleach”.
• Do not attempt to disassemble the unit.
• Do not rub with a scrubbing brush or similar implement.
• Do not utilize washing devices or equipment.
• Do not dry with a hair dryer or other appliance that uses hot air. (The heat can cause the unit
to deform.)
• After cleaning, wait until the unit is completely dried before attaching. The FILTER indicator
may turn on if the unit is used while wet.
• Grasp the handles, and then insert as shown in a. Insert into the right and left guide rails,
and then press in the direction of b after it is all the way in.
• Press both ends of the plasma pure filter in the direction of c until the protrusions on both
sides of the plasma pure filter are completely inserted into the holders.
Press in the plasma pure filter until the protrusions on both sides are completely inserted
into the holders. If installation is incomplete, the FILTER indicator (orange) may light.
6Attach the air filter, and then close the air inlet grille.
A protection feature is provided that prevents the air conditioner from being activated for approximately 3 minutes when it is restarted
immediately after operation or when the power supply switch is set to on. This is used to protect the machine.
Heating characteristics
Preheating operation
The air conditioner does not deliver warm air immediately after it is started.
Warm air flows out after approximately 5 minutes when the indoor heat exchanger has warmed up.
Warm air control
When the room temperature reaches the temperature setting, the fan indoor speed is automatically reduced.
The outdoor unit is stopped at this time.
Defrosting
If frost has formed on the outdoor unit during the heating operation, defrosting is started automatically (for approximately 5 to 10
minutes) to maintain the heating effect.
• The fans in both the indoor and outdoor units stop during the defrost operation.
• During the defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, heat is absorbed from outdoors and released into the room. That is called the heat pump system. When the
outdoor temperature is too low, usage of another heating apparatus in combination with the air conditioner is recommended.
Consideration for accumulated snow
Select the position for the outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. It
is important that the air flow of the outdoor unit is not blocked as this will result in reduced heating or cooling performance. During the
heating mode and at sub-zero temperatures, the water drained off the outdoor unit as a result of the automatic defrost may
accumulate and freeze. It is important that adequate drainage or a soak-way be provided.
Power failure
Power failure during operation stops the unit completely.
• The OPERATION indicator (green) on the indoor unit starts flashing when power is restored.
• To restart operation, push the button on the remote controller.
• Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power supply switch off and then
on again. Push the button on the remote controller to restart.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions.
Cooling operationOutdoor temperature: –10°C to 46°C
Room temperature: 21°C to 32°C
CAUTION
Room relative humidity — less than 80%. If the air conditioner operates outside this
range, the surface of the air conditioner may attract condensation.
Heating operationOutdoor temperature: –15°C to 24°C
Room temperature: Less than 28°C
Dry operationOutdoor temperature: –10°C to 46°C
Room temperature: 17°C to 32°C
If the air conditioner is used in conditions other than above, the safety protection functions may be activated.
If any of the following conditions occur, stop the air conditioner immediately, turn off the main power switch and contact the
dealer.
• The indicators flash at short intervals (5 Hz). Reset the circuit breaker 2 to 3 minutes after the power main switch is turned off.
Despite the resetting operation, the indicators still continue turning on and off.
• The main power fuse often blows, or the circuit breaker is often activated.
• Foreign matter or water has fallen inside the air conditioner.
• Any other unusual conditions are observed.
Before asking for servicing or repairs, check the following points.
Inoperative
• The power main switch is turned off.
• The circuit breaker is activated to cut off the power supply.
• The main power fuse has blown.
• The electric current has stopped.
• The batteries in the remote controller used up.
• The ON timer is set.
• As a protective mechanism for the air conditioner, it does not operate for 3 minutes
immediately after restarting operation or turning on the main power.
Poor cooling or heating performance
Recheck
• The air inlet or outlet of the outdoor unit is blocked.
• Doors or windows are opened.
• The air filter is clogged with dust.
• The louver is not at the correct position.
• The fan speed is set to low.
• The air conditioner is set to the DRY or SLEEP MODE.
• The temperature setting is too high (during cooling operation).
• The temperature setting is too low (during heating operation).
Condensation forms on the back of the indoor unit.
• Condensation on the back of the indoor unit is automatically collected and drained out.
Indoor unit or outdoor unit makes a strange noise.
• When the temperature changes sharply, the indoor or outdoor unit may make a strange
noise (such as a tit-tack noise or flowing noise) because of the expansion/contraction of
parts or change in refrigerant flow.
The room air smells.
A bad odor comes from the air conditioner.
• Smells absorbed in the wall, carpet, furniture, clothing, or furs are coming out.
• During PURE operation, a small amount of ozone is produced, and you might notice the
smell.
Before asking for servicing or repairs, check the following points.
The OPERATION indicator turns on and off.
• The indicator turns on and off (1 Hz) when power is restored after a power failure or when
the power main switch is set to on. Reset the circuit breaker to ON.
Frost forms on the outdoor unit during heating operation.
Water is drained from the outdoor unit.
• Frost sometimes forms on the outdoor unit during heating operation. In that case, the unit
automatically performs defrosting (for 2 to 10 minutes) for improving the heating efficiency.
• In the defrosting operation, the airflow from both the indoor and outdoor units stops.
• A hiss sound is heard when the flow of the refrigerant is changed for defrosting.
• The water resulting from automatic defrosting during the heating operation is drained from
the outdoor unit.
The air flow changes even though the FAN button is not set to the AUTO mode.
• When the temperature of the blown air goes down during heating operation, the air
conditioner automatically changes or stops the air flow from the indoor unit so that the
people in the room do not feel chilly.
A white mist of chilled air or water is generated from the outdoor unit.
• Steam is sometimes generated from the indoor unit during cooling operation or the
outdoor unit during defrosting operation.
Automatic operation of vertical air flow louvers
• When the room temperature or outdoor temperature is high during the heating operation,
the vertical air flow louvers close once and then set themselves automatically to the
original position setting again.
These are not defects.
The FILTER indicator turns on.
• This indicator turns on after PURE operation has been performed for approximately 1000
hours.
• The indicator may turn on if the front panel is not firmly closed.
• The indicator may turn on if the plasma pure filter is not securely attached.
Sounds made from the indoor unit
• The plasma pure filter may make a humming, clicking, or buzzing sound when it is dirty.
• When the power is turned on or the air conditioner is stopped, the vertical air louvers may
make a rattling sound or shuttling sound.
• Some parts may expand or shrink due to temperature fluctuations, and this can result in a
slapping sound.
• When the refrigerant is flowing, a hissing sound or gurgling sound can result.
• A hissing sound can be made when the air conditioner is switched to defrosting operation
during heating operation.
Sounds made from the outdoor unit
• A rustling sound can be made when the air conditioner is switched to defrosting operation
during heating operation.