11.EXPLODED VIEWS AND PARTS LIST .............................................. 51
– 2 –
1. SPECIFICATIONS
RAS-13YK-E/13YA-E, RAS-13YK-ES/13YK-ES
MODEL
ITEM
CapacitykW *1
PhaseSingle
V220–240Power s ource
Hz50
Power consumptionkW1,25–1,29
Power fac t o r%98–95
Running current
Star ting currentA24
Moisture removallit/h2,0
Noise
(SPL at 1 meter)
Refrigerant
Refrigerant controlCapillary tube
Interconnection pipe
Condensate drain pipeOuter diametermm16
INDOOR UNITRAS-13YK-ERAS-13YK-ES
Net weightkg8
Evaporator typeFinned tube
Indoor fan typeCross flow fan
Fan motor outputW20
Air filterPolypropylene net filter (Washable)
OUTDOOR UNITRAS-13YA-ERAS-13YA-ES
Net weightkg3739
Condenser typeFinned tube
Outdoor fan typePropeller
Air flow rate (220–240V)m³/h1700–1900
Fan motor outputW27 (UE6-31C5P)
Compressor
Safety deviceFuse, Overload relay
Auto louverYe s
Usable outdoor temperature range°C21–43
Indoor/OutdoorA0,15/5,66–0,15/5,53
Indoor (H/M/L)dB (A)44 / 39 / 34
Outdoor (220–240V)dB (A)47–4847–48
Name of refrigerantR-22R-410A
Rated volumekg0,900,82
Gas side sizemm12,79,52
Connection typeFlare connection
Liquid side sizemm6,35
Connection typeFlare connection
Maximum length (of one way)m *215
Maximum height difference
Indoor unit
Outdoor unit
Heightmm265
Widthmm790Dimensions
Depthmm189
High fanm³/h650
Medium fanm³/h560Air flow rate
Low fanm³/h510
Heightmm538
Widthmm780Dimensions
Depthmm300
Model2KS224D5CD02PA150X2T-4FM
OutputW1100
↑
↓
V220V–240V
m
RAS-13YK-E/13YA-ERAS-13YK-ES/13YA-ES
Cooling
220V–240V
3,70–3,75
6
Specifications are subject to change without notice.
– 3 –
RAS-13YKX/13YAX, RAS-13YK-HX/11-3YA-HX
MODEL
ITEM
CapacitykW *1
PhaseSingle
V220–240Power source
Hz50
Power consumptionkW1,25–1,291,04–1,08
Power fac to r%98–9598–95
Running current
Starting currentA2422
Moisture removallit/h2,0
Noise
(SPL at 1 meter)
Refrigerant
Refrigerant controlCapillar y tube
Interconnection pipe
Condensate drain pipeOuter diametermm16
INDOOR UNITRAS-13YKXRAS-13YK-HX
Net weightkg8
Evaporat or typeFinned tube
Indoor fan typeCross flow fan
Fan motor outputW20
Air filterPolypropylene net filter (Washable)
OUTDOOR UNITRAS-13YAXRAS-13YA-HX
Net weightkg3740
Condenser typeFinned tube
Outdoor fan typePropeller
Air flow rate (220–240V)m³/h1700–19001730–1930
Fan motor outputW27 (UE6-31C5P) or 30 (HF-240-30A)28 (HF-230-28 P)
Compressor
Safety deviceFuse, Overload relay
Auto louverYe s
Usable outdoor temperature range°C21–43
Indoor (H/M/L)dB (A)44 / 39 / 3444 / 39 / 34
Outdoor (220–240V)dB (A)47–4849–50
Name of refrigerantR-22
Rated volumekg0,800,75
Gas side sizemm12,7
Connection typeFlare connection
Liquid side sizemm6,35
Connection typeFlare connection
Maximum length (of one way)m *215
Maximum height difference
Indoor unit
Outdoor unit
Heightmm265
Widthmm790Dimensions
Depthmm189
High fanm³/h650
Medium fanm³/h560Air flow rate
Low fanm³/h510
Heightmm538
Widthmm780Dimensions
Depthmm300
ModelPH160T2-4L2PH142T2-4K7
OutputW1100
↑
↓
V220V–240V
m
RAS-13YKX/13YAXRAS-13YK-HX/13YA-HX
Cooling
220V–240V
3,70–3,753,55–3,55
6
Specifications are subject to change without notice.
– 4 –
RAS-13YKX-T / 13YAX-T, RAS-13YKX-T2/13YAX-T2
MODEL
ITEM
CapacitykW *1
PhaseSingle
V220Power s ource
Hz50
Power consumptionkW1,161,04
Power fac t o r%98
Running current
Star ting currentA22
Moisture removallit/h2,0
Noise
(SPL at 1 meter)
Refrigerant
Refrigerant controlCapillary tube
Interconnection pipe
Condensate drain pipeOuter diametermm16
INDOOR UNITRAS-13YKX-TRAS-13YKX-T
Net weightkg8
Evaporator typeFinned tube
Indoor fan typeCross flow fan
Fan motor outputW20
Air filterPolypropylene net filter (Washable)
OUTDOOR UNITRAS-13YAX-TRAS-13YAX-T
Net weightkg3841
Condenser typeFinned tube
Outdoor fan typePropeller
Air flow rate (220V)m³/h17001830
Fan motor outputW27 (UE6-31C5P) or 30 (HF-240-30A) 28 (AF-230-28P) or 42 (HF-240-42A)
Compressor
Safety deviceFuse, Overload relay
Auto louverYe s
Usable outdoor temperature range°C21–43
Indoor/OutdoorA0,15/5,240,15/4,68
Indoor (H/M/L)dB (A)44 / 39 / 34
Outdoor (220V)dB (A)4749
Name of refrigerantR-22
Rated volumekg0,720.83
Gas side sizemm12,7
Connection typeFlare connection
Liquid side sizemm6,35
Connection typeFlare connection
Maximum length (of one way)m *215
Maximum height difference
Indoor unit
Outdoor unit
Heightmm265
Widthmm790Dimensions
Depthmm189
High fanm³/h650
Medium fanm³/h560Air flow rate
Low fanm³/h510
Heightmm538
Widthmm780Dimensions
Depthmm300
ModelRM5515FNE96
OutputW1100
↑
↓
V220V
m
RAS-13YKX-T/13YAX-TRAS-13YKX-T2/13YAX-T2
Cooling
220V
3,60
6
Specifications are subject to change without notice.
– 5 –
Note : *1
• Capacity is based on the following temperature conditions.
TEMPERATURE
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
CONDITIONCOOLING
(DB)27 °C
(WB)19 °C
(DB)35 °C
(WB)24 °C
Notes : *2 CHARGELESS
• No additional refrigerant required.
• This air conditioner accepts a connection piping length of up to 15m and a head of up to 6m.
• There is no need to add the refrigerant as long as the total length of the connection piping is up to 15m.
High temperature6,518,0High32/2343/26
Low temperature4,0 2,0Low21/1521/15
• For R-410A (RAS-13YK-ES/13YA-ES)
Standard
50Hz
Standard0,910,0High27/1935/24
High temperature1,116,0High32/2343/26Cooling
Low temperature0,6 2,0Low21/1521/15
pressure P
(kg/cm²G)
Outdoor unit
B
Capillary tube
Ø1,7 x 900
Ø1,7 x 800
Surface temp. of heat
exchanger interchanging
pipe T
Surface temp. of heat
exchanger interchanging
pipe T
(°C)
(°C)
Mark ( ) means check points of Gas Leak
C
Refrigerant
l
l
l
l
Fan s
(indoor)
Fan s
(indoor)
eed
eed
R22 (0,90 kg)
R22 (0,72 kg)
R22 (0,83 kg)
R22 (0,75 kg)
R410A (0,82 kg)
Ambient temp.
conditions DB/WB (°C)
IndoorOutdoor
Ambient temp.
conditions DB/WB (°C)
IndoorOutdoor
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
– 12 –
Indoor Unit Control Panel
C. P. U
Heat Exchanger Sensor
Thermo. Sensor
Infrared Rays Signal Receiver
Infrared
Rays
Remote Control
Operation (START/STOP)
– 13 –
Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Thermo. Setting
Fan Speed Selection
ON TIMER Setting
Initializing Circuit
Clock Frequency
Oscillator Circuit
Power Supply
Circuit
Noise Filter
Functions
• Louver Control
• 3-minute Delay at Restart for Compressor
• Motor Revolution Control
• Processing
(Temperature Processing)
• Timer
Compressor, Outdoor Fan
ON/OFF Signal
ON/OFF Signal
Louver DriverRelay Driver
Louver
Operation
Display
Timer
Display
ECONO.
Sign Display
6. CONTROL BLOCK DIAGRAM
FAN-ONLY
Sign Display
Indoor
Fan Motor
Louver
Motor
OFF TIMER Setting
Louver AUTO Swing
Louver Direction Setting
ECONO.
AC 220-240V
AC 220V
(RAS-13YKX-T, 13YKX-T2 only)
50Hz
50Hz
Relay
RY02
Relay
RY01
Compressor
Outdoor Fan Motor
7. OPERATION DESCRIPTIONS
(Room temp. – Set temp.)
+1
0
Set
temp.
ON
OFF
OPERATION
display
ONON
Compressor
Outdoor fan
(RY01)
Common relay
(RY02)
7-1. FAN ONLY Operation
(The Remote Control MODE Button
is Set to the FAN ONLY Operation)
Once the setting is made, the operation mode is
memorized in the microcomputer so that the same
operation can be effected thereafter simply by
pushing [START/STOP] button.
(MODE of the remote control : FAN ONLY)
(1) During this mode, the relay RY01 is always
turned off so that only the indoor fan is operated.
RY02 is always turnd on. FAN-ONLY display is lit.
1) When the FAN is set to AUTO, the indoor fan
motor operates as shown in Fig 7-1-1.
2) When the FAN is set to LOW, MED. or HIGH,
the indoor fan motor operates with a constant
in volume as listed in Table 7-1-1.
28
HIGH
MED
LOW(+)
LOW
LOW
(Room temp. – Set temp.)
Set
temp.
27
26
25
24
7-2. COOL Operation
(MODE of the remote control : COOL)
(1) Compressor, outdoor fan and operation display
are controlled as shown in Fig. 7-2-1.
Fig. 7-2-1
(2) Relays RY01 and RY02 are turned on to
energize the outdoor unit, and a cool operation is
carried out.
1) When the FAN is set to AUTO, the indoor fan
motor operates as shown in Fig 7-2-2.
2) When the FAN is set to LOW, MED, or HIGH,
the indoor fan motor operates with a constant
in volume as listed in Table 7-1-1.
Fig. 7-1-1 Auto setting of air volume
FAN
Table 7-1-1 Manual setting of FAN SPEED
Indication of
FAN SPEED
LOW
MED
HIGH
HIGH Air volume
(m3/hr)
510
560
650
(Room temp. – Set temp.)
Set
temp.
+4
+3
+2
+1
AUTO
HIGH
MED
LOW(+)
LOW
0
RY01
OFF
LOW
(continuous)
Manual
According
to the set
position
Fig. 7-2-2
(3) Once the setting is made, the operation mode is
memorized in the microcomputer so that the
same operation can be effected thereafter simply
– 14 –
by pushing the START/STOP button.
7-2-1. Louver Control
(Room temp. – Set temp.)
Set
temp.
ON
+3
+2
+1
0
OFF
OPERATION
display
Compressor
Outdoor fan
(RY01)
Common relay
(RY02)
ON:6min.
OFF:4min.
ON:5min.
OFF:5min.
ON
(1) Vertical air flow louvers
Positions of vertical air flow louvers are automatically
controlled according to the operation status (COOL,
AUTO, DRY, FAN ONLY).
Besides, positions of vertical air flow louvers can be
arbitrarily set by pushing the [SET] button.
The louver position which has been set by the [SET]
button is stored in microcomputer, and the louver is
automatically set at the stored position in the next
operation.
(2) Swing
If the [AUTO] button is pushed during running operation, vertical air flow louvers start swinging. When
the [AUTO] button is pushed again, swinging stops.
7-3. DRY Operation
(MODE of the remote control : DRY)
(1) Compressor, outdoor fan and operation display
are controlled as shown in Fig. 7-3-1.
Fig. 7-3-1
• The microprocessor turns the compressor on
and off at regular intervals (4 to 6 minutes on
and/or off).
During the compressor off, the indoor fan will
operate in the super low position.
• The indoor fan will operate in the AUTO
position.
(2) The pattern of operation depending on the
relation between room temperature and set
temperature is shown below:
Room temp.
Set temp.+1
Set temp.
Compressor
Outdoor fan
Indoor fan
– 15 –
ONONONON
OFFOFFOFF
L.*S.L.S.L.L.L.S.L.L.
*Super Low
Fig. 7-3-2
7-4. AUTO Operation
(MODE of the remote control : AUTO)
(1) One of the 2 modes, Cooling or Dry is selected
according to room temperature at which operation is to start, as shown in Fig. 7-4-1. The Fan
mode will continue until room temperature
reaches a level at which another mode is
selected.
7-4-1. Temporary Auto
When the TEMPORARY button is pushed (1 sec),
the set temperature is fixed at 24°C and controlled in
accordance with the chart shown in Fig. 7-4-1.
Powerful
Cooling mode
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
The Louver moved downward. (DIRECT AUTO COOL)
+4
Cooling mode
(The same cooling mode as the room temperature control is set at set temp. –1˚C)
+1
Dry mode
(The same dry operation as the room temperature control is set at set temp. –1˚C)
(Room temp. – Set temp.)
7-5. ECONO. Mode
When the ECONO. button is pushed, during COOL
and AUTO operation, the OPERATION display is
turned off and the ECONO. display is lit and the
indoor unit operates quietly and mildly with
controlling airflow.
7-5-1. Cooling
(1) In the ECONO. mode, the set temp. by the
remote control is changed automatically as
shown in Fig. 7-5-1.
(2) Fan speed → LOW
(˚C)
Set temp.
is changed
Fig. 7-4-1
Heat exchanger
temperature
7-6. Low-Temperature Limit Control
(Cooling Operation)
The microprocessor detects the indoor heat exchanger temperature so as to prevent freezing up the
indoor heat exchanger.
Control is performed as shown in Fig. 7-6-1.
(˚C)
Compressor
7
5
Less than 5˚C continues
Outdoor fan
ON
for 5 minutes
OFF
Set temp.
+2
+1
ECONO. button
is pushed
Set temp.
is changed
Fig. 7-6-1
1H2HTIME0H
Fig. 7-5-1
– 16 –
7-7. Auto Restart Function
This unit is equipped with an Automatic restarting
function which allows the unit to restart and resume
the set operating conditions in the event of a supply
power shutdown without the use of the hand control.
The operation will resume without warning three
minutes after the power is restored.
INFORMATION
The AUTO RESTART FUNCTION is set not to work
on shipment from the factory, and so it is necessary
to set it to function as required.
• When the system is stand-by (not running)
7-7-1. How to Set the Auto Restart
To set the Auto Restart function, proceed as follows:
Access the TEMPORARY button located in the lower
right hand corner beneath the hinged front panel of
the indoor unit.
The power supply to the unit must be on - the function will not be set if the power is off.
To enable the Auto Restart function, push the TEMPORARY button continuously for three seconds.
The unit will acknowledge the setting and beep three
times. The system will now restart automatically.
The above Auto Restart settings can be carried out:
OPERATION
Push the TEMPORARY button
continuously more than three
seconds.
0
TEMPORARY
• When the system is operating
OPERATION
Push the TEMPORARY button
continuously more than three
seconds.
0
TEMPORARY
MOTION
Stand-by
↓
The system starts to operate.The green light will be lit.
↓about three seconds after
3S
The unit beeps three times.The orange light will be lit.
↓
The system is operating.The orange light is lighting.
If the system is not required to run at this time, push the TEMPORARY
button once more or use the remote control and the unit will stop.
MOTION
OperatingThe green light is lit.
↓
The system stops to operate.The green light is turned off.
↓about three seconds after
3S
The unit beeps three times.
↓
The system stops.
If the system is not required to stop at this time, use the remote control
and to restart.
During subsequent operation, the orange light goes on.
• The Auto Restart function will not accept an instruction if timer operation with the remote control is selected.
• During louver swing (AUTO) operation, after restarting by the Auto Restart function, the louver swing stops.
– 17 –
7-7-2. How to Cancel the Auto Restart
To cancel the Auto Restart function, proceed as follows:
Repeat the setting procedure: the unit will acknowledge the instruction and beep three times.
The system will now be required to manually restart with the remote control after the main supply is turned off.
Cancellation is carried out:
• When the system is stand-by (not running)
OPERATION
Push the TEMPORARY button
continuously more than three
seconds.
0
TEMPORARY
• When the system is operating
OPERATION
Push the TEMPORARY button
continuously more than three
seconds.
0
TEMPORARY
MOTION
Stand-by
↓
The system starts to operate.The orange light will be lit.
↓about three seconds after
3S
The unit beeps three times.The green light will be lit.
↓
The system is operating.
If the system is not required to run at this time, push the TEMPORARY
button once more or use the remote control and Stop the unit.
MOTION
OperatingThe orange light is lit.
↓
The system stops to operate.The orange light is turned off.
↓about three seconds after
3S
The unit beeps three times.
↓
The system stops.
If the system is not required to stop at this time, use the remote control
and to restart.
During subsequent operation, the green light goes on.
7-7-3. In Case of Power Failure during the Timer Operation
(1) If ON-TIMER operation is reserved with setting of Auto Restart operation, it is cancelled with power failure.
(The OPERATION lamp on the main unit goes on and off to inform of power failure.) In that case, try to
reserve ON-TIMER operation once again.
(2) If OFF-TIMER operation is reserved without setting of Auto Restart operation, the reservation is cancelled
with power failure. (The OPERATION lamp on the main unit goes on and off to inform of power failure.) In that
case, try to reserve OFF-TIMER operation. When Auto Restart operation is set, OFF-TIMER reservation is
also cancelled with power failure.
– 18 –