Toshiba RAS-07UAH-E4, RAS-07UKP-E4, RAS-07UKHP-E4, RAS-10UKP-E4, RAS-10UKHP-E4 SERVICE MANUAL

...
SERVICE MANUAL
AIR CONDITIONER
SPLIT WALL TYPE
RAS-13UKHP-E4 / RAS-13UAH-E4 RAS-10UKHP-E4 / RAS-10UAH-E4
RAS-07UKHP-E4 / RAS-07UAH-E4
FILE NO. SVM-05001-1
RAS-13UKP-E4 / RAS-13UA-E4 RAS-10UKP-E4 / RAS-10UA-E4 RAS-07UKP-E4 / RAS-07UA-E4
RAS-13UKPX4 / RAS-13UAX4
RAS-10UKPX4 / RAS-10UAX4 RAS-07UKPX4 / RAS-07UAX4 RAS-12UKPX4 / RAS-12UAX4
Revised Aug, 2005
FILE NO. SVM-05001
CONTENTS
1. SPECIFICATIONS
2. CONSTRUCTION VIEWS
2-1 Indoor Unit
2-2 Outdoor Unit (RAS-13UAH-E4, RAS-10UAH-E4, RAS-13UA-E4, RAS-10UA-E4,
RAS-13UAX4, RAS-10UAX4, RAS-12UAX4)
2-3 Outdoor Unit (RAS-07UAH-E4, RAS-07UA-E4, RAS-07UAX4)
3. WIRING DIAGRAM
3-1 RAS-13UKHP-E4 / RAS-13UAH-E4 3-2 RAS-10UKHP-E4 / RAS-10UAH-E4 3-3 RAS-07UKHP-E4 / RAS-07UAH-E4 3-4 RAS-13UKP-E4 / RAS-13UA-E4
RAS-10UKP-E4 / RAS-10UA-E4
3-5
RAS-07UKP-E4 / RAS-07UA-E4 RAS-13UKPX4 / RAS-13UAX4
3-6
RAS-12UKPX4 / RAS-12UAX4
3-7 RAS-10UKPX4 / RAS-10UAX4
RAS-07UKPX4 / RAS-07UAX4
4. SPECIFICATION OF ELECTRICAL PARTS
4-1 Indoor Unit (RAS-13UKHP-E4, RAS-10UKHP-E4, RAS-07UKHP-E4) 4-2 Outdoor Unit (RAS-13UAH-E4) 4-3 Outdoor Unit (RAS-10UAH-E4) 4-4 Outdoor Unit (RAS-07UAH-E4) 4-5 Indoor Unit (RAS-13UKP-E4, RAS-10UKP-E4, RAS-07UKP-E4, RAS-13UKPX4)
RAS-10UKPX4, RAS-12UKPX4, RAS-07UKPX4) 4-6 Outdoor Unit (RAS-13UA-E4) 4-7 Outdoor Unit (RAS-13UAX4, RAS-12UAX4) 4-8 Outdoor Unit (RAS-10UA-E4, RAS-10UAX4)
4-9 Outdoor Unit (RAS-07UAX4)
4-10 Outdoor Unit (RAS-07UA-E4)
5. REFRIGERATION CYCLE DIAGRAM
5-1 RAS-13UKHP-E4 / RAS-13UAH-E4 5-2 RAS-10UKHP-E4 / RAS-10UAH-E4 5-3 RAS-07UKHP-E4 / RAS-07UAH-E4 5-4 RAS-13UKP-E4 / RAS-13UA-E4, RAS-13UKPX4 / RAS-13UAX4,
RAS-12UKPX4 / RAS-12UAX4
5-5 RAS-10UKP-E4 / RAS-10UA-E4, RAS-10UKPX4 / RAS-10UAX4 5-6 RAS-07UKP-E4 / RAS-07UA-E4, RAS-07UKPX4 / RAS-07UAX4
6. CONTROL BLOCK DIAGRAM
6-1 RAS-13UKHP-E4 / RAS-13UAH-E4, RAS-10UKHP-E4 / RAS-10UAH-E4,
RAS-07UKHP-E4 / RAS-07UAH-E4
6-2 RAS-13UKP-E4 / RAS-13UA-E4, RAS-10UKP-E4 / RAS-10UA-E4,
RAS-07UKP-E4 / RAS-07UA-E4, RAS-13UKPX4 / RAS-13UAX4, RAS-07UKPX4 / RAS-07UAX4, RAS-12UKPX4 / RAS-12UAX4
7. OPERATION DESCRIPTION
7-1 Outline of Air Conditioner Control 7-2 Description of Operation Circuit 7-3 Hi POWER Mode 7-4 High-Temperature Limit Control 7-5 Low-Temperature Limit Control 7-6 Defrost Operation 7-7 Current Limit Control 7-8 Auto Restart Function 7-9 Filter Check Lamp 7-10 Self-Cleaning function
7-11 QUIET Mode 7-12 COMFORT SLEEP mode
8. INSTALLATION PROCEDURE
8-1 Safety Cautions 8-2 Installation Diagram of Indoor and Outdoor Units 8-3 Installation 8-4 Indoor Unit 8-5 Outdoor Unit 8-6 How to Set Remote Control Selector Switch
FILE NO. SVM-05001
8-7 Others
9. TROUBLESHOOTING CHART
9-1 Troubleshooting Procedure 9-2 Basic Check Items 9-3 Primary Judgement 9-4 Self-Diagnosis by Remote Control (Check Code) 9-5 Troubleshooting Flowcharts
9-6 Troubleshooting for Remote Control
10. PART REPLACEMENT
10-1 Indoor Unit 10-2 Outdoor Unit
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy for Heat pump model) 11-2 Indoor Unit (E-Parts Assy for Cooling model) 11-3 Indoor Unit (RAS-07,10,13UKHP-E4, UKP-E4)
11-4 Indoor Unit (RAS-07,10,12,13UKPX4) 11-5 Outdoor Unit (RAS-13UAH-E4)
11-6 Outdoor Unit (RAS-10UAH-E4) 11-7 Outdoor Unit (RAS-13UA-E4) 11-8 Outdoor Unit (RAS-10UA-E4) 11-9 Outdoor Unit (RAS-13UAX4, RAS-12UAX4) 11-10 Outdoor Unit (RAS-10UAX4)
11-11 Outdoor Unit (RAS-07UAX4, RAS-07UA-E4) 11-12 Outdoor Unit (RAS-07UAH-E4)
- 2 -
FILE NO. SVM-05001
1. SPECIFICATIONS
MODEL RAS-13UKHP-E4 / RAS-13UAH-E 4 RAS-13UKP-E4 / RAS-13UA-E4
ITEM Cooling Heating Cooling
Capacity
Power source V 220 - 240
Power consumption kW 1.23 1.27 1.26 1.33 1.24 1.28 Power factor % 99 97 98 96 98 95
Running Indoor A 0.15
current Outdoor A 5.50 5.30 5.35 5.15 5.75 5.60
Starting current A 25 24
Moisture removal lit/h 2.0
Noise
Refrigerant
Refrigerant control Capillary tube
Interconnection
pipe
INDOOR UNIT RAS-13UKHP-E4 RAS-13UKP-E4
Dimensions Width mm 790
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
Air volume Medium fan m3/h 520 550 520
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-13UAH-E4 RAS-13UA-E4
Dimensions Width mm 780
Net weight kg 37 34
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 2120
Fan motor output W
Compressor
Safety device Fuse, Overload relay
Louver type Automatic louver Usable outdoor temperature range °C 15 ~ 43 -10 ~ 24 15 ~ 43
Indoor (H/M/L) dB 41/35/31 Outdoor (220 - 240 V) dB 49 51 49 51 47 48
Name of refrigerant R22
Rated amount kg 1.00 0.80
Gas side size mm Æ12.7
Connection type Flare connection Liquid side size mm Æ6.35
Connection type Flare connection
Maximum length (One way)
Maximum height difference
Height mm 275
Depth mm 208
High fan m3/h 630 650 630
Low fan m3/h 430 490 430
Height mm 550
Depth mm 270
Model
Output W 1100
kW 3.55 3.60 4.10 4.15 3.70 3.75
Phase 1Æ
Hz 50
m
m
220 V 240 V 220 V 240 V 220 V 240 V
1
15*
6
2200
2120 2200 2030 2150
42
PH225X2C-4FT
30
3
FILE NO. SVM-05001
MODEL RAS-10UKHP-E4 / RAS-10UAH-E4 RAS-10UKP-E4 / RAS-10UA-E4
ITEM Cooling Heating Cooling
Capacity
Power source V 220 - 240
Power consumption kW 0.93 0.98 0.84 0.86 0.80 0.85
Power factor % 95 92 94 91 97 95
Running Indoor A 0.15
current Outdoor A 4.30 4.27 3.90 3.77 3.60 3.58
Starting current A 19 16
Moisture removal lit/h 1.2
Noise
Refrigerant
Refrigerant control Capillary tube
Interconnection
pipe
INDOOR UNIT RAS-10UKHP-E4 RAS-10UKP-E4
Dimensions Width mm 790
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
Air volume Medium fan m3/h 460 520 460
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10UAH-E4 RAS-10UA-E4
Dimensions Width mm 780
Net weight kg 32 31
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 1740 1850 1740 1850 1740 1850
Fan motor output W 20
Compressor
Safety device Fuse, Overload relay
Louver type Automatic louver Usable outdoor temperature range °C 15 ~ 43 -10 ~ 24 15 ~ 43
Indoor (H/M/L) dB 39/33/26 Outdoor (220 - 240 V) dB 47 49 47 49 44 45
Name of refrigerant R22
Rated amount kg 0.76 0.68
Gas side size mm Æ9.52
Connection type Flare connection Liquid side size mm Æ6.35
Connection type Flare connection
Maximum length (One way)
Maximum height difference
Height mm 275
Depth mm 208
High fan m3/h 570 610 610
Low fan m3/h 340 400 340
Height mm 550
Depth mm 270
Model PH180X1C-4DZDN3 RM5510GNE94
Output W 750
kW 2.65 2.70 2.95 3.00 2.65 2.70
Phase 1Æ
Hz 50
m 10*
m
220 V 240 V 220 V 240 V 220 V 240 V
1
5
- 4 -
FILE NO. SVM-05001
MODEL
RAS-07UKHP-E4/ RAS-07UKP-E4/ RAS-07UKPX4/
RAS-07UAH-E4 RAS-07UA-E4 RAS-07UAX4
ITEM Cooling Heating Cooling Cooling
Capacity
Phase 1
Power source V 220 240
Power consumption kW 0.61 0.68 0.54 0.59 0.58 0.62 0.58 0.62 Power factor % 98 97 98 96 98 96 98 96
Running Indoor A 0.15 current Outdoor A 2.69 2.77 2.35 2.40 2.55 2.55 2.55 2.55
Starting current A 13 11
Moisture removal lit/h 0.8
Noise Indoor (H/M/L) dB 38/32/26
Outdoor (220-240V) dB
Refrigerant
Refrigerant control Capillary tube
Interconnection
pipe
Name of refrigerant R-22 Rated amount kg 0.60 0.57
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Connection type Flare connection
Maximum length (One way)
Maximum height difference
220V 240V 220V 240V 220V 240V 220V 240V
kW 2.00 2.05 2.00 2.05 2.10 2.15 2.10 2.15
Hz 50
44
m 10*
m 5
45 45
46
44 45
1
44
45
INDOOR UNIT RAS-07UKHP-E4 RAS-07UKP-E4 RAS-07UKPX4
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m3/h 570 610 570
Air volume Medium fan m3/h 460 490 460
Low fan m3/h 340 400 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07UAH-E4 RAS-07UA-E4 RAS-07UAX4
Height mm 530
Dimensions Width mm 660
Depth mm 240
Net weight kg 28 27
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 1280 1360 1280 1360 1280 1360 1280 1360
Fan motor output W 20
Compressor
Safety device Fuse, Overload relay
Louver type Automatic louver Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 15 ~ 43
Model PH108X1C-4DZDN2
Output W 605
21 ~ 43
5
FILE NO. SVM-05001
ITEM Cooling
MODEL
Capacity
RAS-13UKPX4 / RAS-13UAX4 RAS-12UKPX4 / RAS-12UAX4 RAS-10UKPX4 / RAS-10UAX4
220 V 240 V 220 V 240 V
kW 3.70 3.75 2.65 2.70
220 V
240 V
3.483.40
Phase 1Æ
Power source V 220 - 240
Hz 50 Power consumption kW 1.24 1.28 0.80 0.85 Pow er factor % 98 95 97 95
1.24 98 95
1.28
Running Indoor A 0.15 current Outdoor A 5.60 5.45 3.60 3.58
5.60 5.45
Starting current A 24 16 Moisture removal lit/h 2.0 1.2
Noise
Refrigerant
Indoor (H/M/L) dB 41/35/31 39/33/26 Outdoor dB 47 48 44 45
47 48
Name of refrigerant R22 Rated amount kg 0.80 0.68
Refrigerant control Capillar y tube
Gas side size mm Æ12.70 Æ9.52 Connection type Flare connection
Liquid side size mm ∅6.35 Interconnection pipe
Connection type Flare connection
Maximum length
(One way)
Maximum height
difference
m 15*
m
1
6 5
10*
1
INDOOR UNIT RAS-13UKPX4 RAS-12UKPX4 RAS-10UKPX4
Height mm 275 Dimensions Width mm 790
Depth mm 208 Net weight kg 10 Evaporator type Finned tube Indoor fan type Cross flow fan
High fan m3/h 630 610 Air volume Medium fan m3/h 520 460
Low fan m3/h 430 340 Fan motor output W 20 Air filter Honeycomb woven filter with PP frame OUTDOOR UNIT RAS-13UAX4 RAS-12UAX4 RAS-10UAX4
Height mm 550 Dimensions Width mm 780
Depth mm 270 Net weight kg 34 31 Condenser type Finned tube Outdoor fan type Propeller fan Airflow volume m3/h 2030 2150 1740 1850
2030
2150
Fan motor output W 30 20 Compressor
Model PH225X2C-4FT RM5510GNE94
Output W 1100 750 Safety device Fuse, Overload relay Louver type Automatic louver Usable outdoor temperature range °C 21 ~ 43
Note : 1
·
Capacity is based on the following temperature conditions.
FILE NO. SVM-05001
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Note : 2
*1 No need to charge extra refrigerant.
Condition
Cooling Heating
(DB) 27°C20°C
(WB) 19°C15°C
(DB) 35°C7°C
(WB) 24°C6°C
JIS B8615-1
- 7 -
2-1. Indoor Unit
FILE NO. SVM-05001
2. CONSTRUCTION VIEWS
Front panel
Back body
0
66
48
Knock out system
Air inlet
Air filter
790
Heat exchanger
275
Air outlet
120 80
590
Hanger
64
53
48
208
48
Knock out system
0
66
Drain hose (0.54 m)
Hanger
45
Minimum distance to ceiling
275
170 or mor
e
320
Connecting pipe (0.33 m)
(For 13 series ; Flare 12.7 For 07,10 series ; Flare
620
235
215
Minimum distance to ceiling
Hanger
more 5 or
6
235
215
Hanger
160
Installation plate outline
Center line
8
Connecting pipe (0.43 m)
6.35)
(Flare
For stud bolt
8~10)
(
For stud bolt (
26
Minimum distance to ceiling
170 or more
Hanger
150150 160
32
9090
9.52)
6)
4519040
57
Wireless remote control
160
18
FILE NO. SVM-05001
2-2. Outdoor Unit (RAS-13UAH-E4, RAS-10UAH-E4, RAS-13UA-E4, RAS-10UA-E4,
RAS-13UAX4, RAS-10UAX4, RAS-12UAX4)
A
A
Detail Drawing (Back Leg)
6 Hole
302
310
32.5
600
52 36
270
R15
R5.5
310
302
30 Drain outlet
436
530
265
FAN GUARD
115
125
11 x 14 Hole
2-
8-∅
(For
10 anchor bolt)
90
600 780
62
102
6 Hole
11 x 14 Hole
B
B Detail Drawing (Front Leg)
310
302
36
52
R15
310 330
COVER PV
Z
Electrical part cover
Installation dimension
B or more
325
100 or more
Z
Air outlet
View
600
Air inlet
A or more
600 or more
120
54
75
11 Long holes (For 8-∅10 anchor bolt)
4 x
12,
13 Series
600 mm 400 mm
A
B 100 mm 45 mm
Liquid side (Flare 6.35)
Gas side (Flare 9.52) 10 Series
Gas side (Flare 12.7) 12, 13 Series
Service port
10 Series
9
2-3. Outdoor Unit (RAS-07UAH-E4, RAS-07UA-E4, RAS-07UAX4)
A
97
A
Detail Drawing (Back Leg)
660
50
36
6 Hole
265
273.5
R 15
R 5.5
530
273.5
420
59.5
Fan guard
25Drain outlet
2-
11x14 hole
8-∅
(for
B
10 anchor bolt)
B
11x14 Hole
FILE NO. SVM-05001
Detail Drawing (Front Leg)
265
273.5
6 Hole
36 50
R 15
660
Cover PV
Z
242
Installation dimension
100 or more
325
100 or more
Air outlet
500
660
View
Z
600
Air inlet
600 or more
97.5
600 or more
4x
(11)
56
11x14 Long holes (for 8-∅10 anchor bolt)
126
48
297
54
Service port
(12.5)273.5 (pitch)
Liquid side (Flare
Gas side (Flare
6.35)
9.62)
10
3. WIRING DIAGRAM
3-1. RAS-13UKHP-E4 / RAS-13UAH-E4
FILE NO. SVM-05001
BRW
L
BLU
N
GRN & YEL
SINGLE PHASE
220-240V 50Hz
BLK P04
T02 C.T.
131
CN27
73°C
THERMAL FUSE
Louver Motor
CN25
PNK
SG01
DSA
VARISTOR
BLK
R22
3
4
PNK
112
RY01
2
CN04
T6.3A 250VAC
FUSE F01
MAIN P.C. BOARD
YEL
54321
54321
C01
R21
VARISTOR
YEL
CN07
YEL
YEL
WHI
DC5V
L01
WP-003
RY04RY03
CR01
150°C
1 1
3
CN03
112
BLK
2
BLK
THERMO
SENSOR (TA)
CN01
112
HEAT EXCHANGER
2
BLK
BLK
CR02
SENSOR (TC)
2 2 3 3 4 4 5 5 6 6
INFRARED RAYS RECEIVE
AND INDICATION PARTS
345
1
2
345
1
2
BLU
BLU
BLU
345
2
345
2
Voltage
Regulator
IC03
BLU
R319
R26
BLU
1
1
C02
CR03
C15
5
CN10
BLK
5
GRY YEL
BRW
RED
WHI
789
6
789
6
BLU
BLU
789
6
789
6
Micro
Power
Module
R25
R27
3 1 3 1
10
11
10
11
BLU
BLU
BLU
10
11
10
11
CN14
DC12V
+
DB01 C63
CN11
1 2 3 1 2 3
WHI
INDOOR TERMINAL BLOCK
OUTDOOR TERMINAL BLOCK
COMPRESSOR
BLK
BLK
WHI
2
1 4
(L)2(N)
1
BLK
SOLENOID COIL
RED
RED
RED
PNK
WHI
CAPACITOR
BLU
RED
3
3
BLU
CAPACITOR
FAN MOTOR
BLU
4
WHI
AC FAN MOTOR
GRN&YEL
INDOOR
OUTDOOR
CHASSIS
BLK
11
3-2. RAS-10UKHP-E4 / RAS-10UAH-E4
FILE NO. SVM-05001
BRW
L
BLU
N
GRN & YEL
SINGLE PHASE
220-240V 50Hz
BLK P04
T02 C.T.
131
CN27
73°C
THERMAL FUSE
Louver Motor
CN25
PNK
SG01
DSA
VARISTOR
BLK
R22
3
4
PNK
112
RY01
2
CN04
T6.3A 250VAC
FUSE F01
MAIN P.C. BOARD
YEL
54321
54321
C01
R21
VARISTOR
YEL
CN07
YEL
YEL
WHI
DC5V
L01
WP-003
RY04RY03
CR01
150°C
1 1
3
CN03
112
BLK
2
BLK
THERMO
SENSOR (TA)
CN01
112
HEAT EXCHANGER
2
BLK
BLK
CR02
SENSOR (TC)
2 2 3 3 4 4 5 5 6 6
INFRARED RAYS RECEIVE
AND INDICATION PARTS
345
1
2
345
1
2
BLU
BLU
BLU
345
2
345
2
Voltage
Regulator
IC03
BLU
R319
R26
BLU
1
1
C02
CR03
C15
5
CN10
BLK
5
GRY YEL
BRW
RED
WHI
789
6
789
6
BLU
BLU
789
6
789
6
Micro
Power
Module
R25
R27
3 1 3 1
10
11
10
11
BLU
BLU
BLU
10
11
10
11
CN14
DC12V
+
DB01 C63
CN11
1 2 3 1 2 3
WHI
INDOOR TERMINAL BLOCK
OUTDOOR TERMINAL BLOCK
OVERLOAD RELAY
COMPRESSOR
BLK
BLK
WHI
2
1 4
(L)2(N)
1
BLK
SOLENOID COIL
RED
RED
RED
PNK
WHI
CAPACITOR
BLU
RED
3
3
BLU
CAPACITOR
FAN MOTOR
BLU
GRN&YEL
4
WHI BLK
AC FAN MOTOR
INDOOR
OUTDOOR
CHASSIS
12
3-3. RAS-07UKHP-E4 / RAS-07UAH-E4
FILE NO. SVM-05001
BRW
L
BLU
N
GRN & YEL
SINGLE PHASE
220-240V 50Hz
BLK P04
T02 C.T.
131
CN27
73°C
THERMAL FUSE
Louver Motor
CN25
PNK
SG01
DSA
VARISTOR
BLK
R22
3
4
PNK
112
RY01
2
CN04
T6.3A 250VAC
FUSE F01
MAIN P.C. BOARD
YEL
54321
54321
C01
R21
VARISTOR
YEL
CN07
YEL
YEL
WHI
DC5V
L01
WP-003
RY04RY03
CR01
150°C
1 1
3
CN03
112
BLK
2
BLK
THERMO
SENSOR (TA)
CN01
112
HEAT EXCHANGER
2
BLK
BLK
CR02
SENSOR (TC)
2 2 3 3 4 4 5 5 6 6
INFRARED RAYS RECEIVE
AND INDICATION PARTS
345
1
2
345
1
2
BLU
BLU
BLU
345
2
345
2
Voltage
Regulator
IC03
BLU
R319
R26
BLU
1
1
C02
CR03
C15
5
CN10
BLK
5
GRY YEL
BRW
RED
WHI
789
6
789
6
BLU
BLU
789
6
789
6
Micro
Power
Module
R25
R27
3 1 3 1
10
11
10
11
BLU
BLU
BLU
10
11
10
11
CN14
DC12V
+
DB01 C63
CN11
1 2 3 1 2 3
WHI
INDOOR TERMINAL BLOCK
OUTDOOR TERMINAL BLOCK
OVERLOAD RELAY
COMPRESSOR
BLK
BLK
PNK
WHI
BLK
1
(L)2(N)
1
RED
WHI
2
BLU
SOLENOID COIL
RED
RED
CAPACITOR
RED
3
3
BLU
CAPACITOR
FAN MOTOR
BLU
4
4
WHI
AC FAN MOTOR
GRN&YEL
INDOOR
OUTDOOR
CHASSIS
BLK
13
3-4. RAS-13UKP-E4 / RAS-13UA-E4
Infrared rays receiver and indication parts.
Heat Exchanger Sensor (TC)
Thermo Sensor (TA)
L
N
Single Phase
220V~, 50Hz
GRN&YEL
BRW (L)
BLU (N)
CN01
121
CN03
121
CN25
CN14
2
2
1 1
BLU
1 1
2
BLU
2
43 432
BLU
BLU
432 43
F01
T6.3 A
250 VAC
8
6
7
5 5
BLU
5
R21 R22
C15
6
BLU
6 6587
3
9 11
8
7
9
BLU
BLU
BLU
8
7
9 9
RY01
L01
2
2
3
10 10
10 10
FILE NO. SVM-05001
RED
TRANS (T T-10)
WHI
113
CN05 CN06
3
DB50
C50
+
IC03
BLU
R46
113
Regulator
circuit
R47
R48
GRY
3
MCC-920
DC 12 V
DC 5 V
CN07 1 2 3 4 5
WHI
1
YEL YEL YEL YEL
1
2
2
3
3
4
4
5
5
1 2 3 4 5
Louver motor
CN11
YEL
1
1
GRY
2
2
D38
CR03
C58
3
CN10
5
3
1
BRW
3
WHI
5
BLK
3
RED
1
1 2 3 4 5 6 6
150 C 1 2 3 4 5
Indoor FAN motor
11
BLU
WHI
11
BLK
11
P04
4
SG01
DSA
1
C01
4
CN31
INDOOR
TERMINAL
BLK
1
BLOCK
OUTDOOR TERMINAL
BLOCK
BLK BLK RED
1(L) 2(N)
FAN MOTOR
WHI
2
RED
WHI
COMPRESSOR
GRN&YEL
CHASSIS
CAPACITOR
RED
PNK
WHI
INDOOR
OUTDOOR
CAPACITOR
CN04
PNK
112
2
PNK
TEMP FUSE
73 C
14
3-5. RAS-10UKP-E4 / RAS-10UA-E4
RAS-07UKP-E4 / RAS-07UA-E4
Infrared rays receiver and indication parts.
Heat Exchanger Sensor (TC)
Thermo Sensor (TA)
L
N
Single Phase
220V~, 50Hz
GRN&YEL
BRW (L)
BLU (N)
CN01
121
CN03
121
CN25
CN14
2
2
1 1
BLU
1 1
2
BLU
2
43 432
BLU
BLU
432 43
F01
T6.3 A
250 VAC
8
6
7
5 5
BLU
5
R21 R22
C15
6
BLU
6 6587
3
9 11
8
7
9
BLU
BLU
BLU
8
7
9 9
RY01
L01
2
2
3
10 10
10 10
FILE NO. SVM-05001
RED
TRANS (T T-10)
WHI
113
CN05 CN06
3
DB50
C50
+
IC03
BLU
R46
113
Regulator
circuit
R47
R48
GRY
3
MCC-920
DC 12 V
DC 5 V
CN07 1 2 3 4 5
WHI
1
YEL YEL YEL YEL
1
2
2
3
3
4
4
5
5
1 2 3 4 5
Louver motor
CN11
YEL
1
1
GRY
2
2
D38
CR03
C58
3
CN10
5
3
1
BRW
3
WHI
5
BLK
3
RED
1
1 2 3 4 5 6 6
150 C 1 2 3 4 5
Indoor FAN motor
11
BLU
WHI
11
BLK
11
P04
4
SG01
DSA
1
C01
4
INDOOR
TERMINAL
BLOCK
OUTDOOR TERMINAL BLOCK
BLK
BLK
OVERLOAD RELAY
CN31
BLK
1
1
FAN MOTOR
BLK
(L)
WHI
2
(N)
2
RED
RED
WHI
COMPRESSOR
GRN&YEL
CHASSIS
RED
CAPACITOR
PNK WHI
INDOOR
OUTDOOR
CAPACITOR
CN04
PNK
112
2
PNK
TEMP FUSE
73 C
15
3-6. RAS-13UKPX4 / RAS-13UAX4
RAS-12UKPX4 / RAS-12UAX4
Infrared rays receiver and indication parts.
Heat Exchanger Sensor (TC)
Thermo Sensor (TA)
GRN&YEL
Single Phase
BLU (N) BRW (L)
Power Cord
220-240V 50Hz
CN01
121
CN03
121
CN25
CN14
2
2
1 1
BLU
1 1
2
BLU
2
43 432
BLU
BLU
432 43
F01
T6.3 A
250 VAC
8
6
7
5 5
BLU
5
R21 R22
C15
6
BLU
6 6587
3
9 11
8
7
9
BLU
BLU
BLU
8
7
9 9
RY01
L01
2
2
3
FILE NO. SVM-05001
10 10
11
BLU
WHI
10
11
10
BLK
11
P04
4
SG01
DSA
1
C01
4
RED
TRANS (T T-10)
WHI
113
CN05 CN06
3
DB50
C50
+
IC03
BLU
R46
113
Regulator
circuit
R47
R48
GRY
3
MCC-920
DC 12 V
DC 5 V
CN07 1 2 3 4 5
WHI
1
YEL YEL YEL YEL
1
2
2
3
3
4
4
5
5
1 2 3 4 5
Louver motor
CN11
YEL
1
1
GRY
2
2
D38
CR03
C58
3
CN10
5
3
1
BRW
3
WHI
5
BLK
3
RED
1
1 2 3 4 5 6 6
150 C 1 2 3 4 5
Indoor FAN motor
CN31
INDOOR
TERMINAL
BLK
1
BLOCK
OUTDOOR TERMINAL
BLOCK
BLK BLK RED
1(L) 2(N)
FAN MOTOR
WHI
2
RED
WHI
COMPRESSOR
GRN&YEL
CHASSIS
CAPACITOR
RED
PNK
WHI
INDOOR
OUTDOOR
CAPACITOR
CN04
PNK
112
2
PNK
TEMP FUSE
73 C
16
3.7 RAS-10UKPX4 / RAS-10UAX4 RAS-07UKPX4 / RAS-07UAX4
Infrared rays receiver and indication parts.
Heat Exchanger Sensor (TC)
Thermo Sensor (TA)
GRN&YEL
Single Phase
BLU (N) BRW (L)
Power Cord
220-240V 50Hz
CN01
121
CN03
121
CN25
CN14
2
2
1 1
BLU
1 1
2
BLU
2
43 432
BLU
BLU
432 43
F01
T6.3 A
250 VAC
8
6
7
5 5
BLU
5
R21 R22
C15
6
BLU
6 6587
3
9 11
8
7
9
BLU
BLU
BLU
8
7
9 9
RY01
L01
2
2
3
FILE NO. SVM-05001
10 10
11
BLU
WHI
10
11
10
BLK
11
P04
4
SG01
DSA
1
C01
4
RED
TRANS (T T-10)
WHI
113
CN05 CN06
3
DB50
C50
+
IC03
R46
BLU
113
Regulator
circuit
R47
R48
GRY
3
MCC-920
DC 12 V
DC 5 V
CN07 1 2 3 4 5
WHI
1
YEL YEL YEL YEL
1
2
2
3
3
4
4
5
5
1 2 3 4 5
Louver motor
CN11
YEL
1
1
GRY
2
2
D38
CR03
C58
3
CN10
5
3
1
BRW
3
WHI
5
BLK
3
RED
1
1 2 3 4 5 6 6
150 C 1 2 3 4 5
Indoor FAN motor
INDOOR
TERMINAL
BLOCK
OUTDOOR TERMINAL BLOCK
BLK
BLK
OVERLOAD RELAY
CN31
BLK
1
(L)
1
FAN MOTOR
BLK
WHI
2
(N)
2
RED
RED
WHI
COMPRESSOR
GRN&YEL
CHASSIS
RED
CAPACITOR
PNK WHI
INDOOR
OUTDOOR
CAPACITOR
CN04
PNK
112
2
PNK
TEMP FUSE
73 C
17
FILE NO. SVM-05001
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13UKHP-E4, RAS-10UKHP-E4, RAS-07UKHP-E4)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150 C thermo fuse 2 Thermo sensor (TA-sensor) 10k at 25 C 3 Micro Power Module (M01) 4 Microcontroller unit (IC30) TMP87CM40AN 5 Heat exchanger sensor
(TC-sensor) 6 Line filter (L01) LC*SS11V-06270 27mH, 600mA 7 Bridge rectifier (DB01) D3SBA60 4A, 600 V 8 Capacitor (C63) KMH400VSSN47M22S 47mF, 400 V 9 Fuse (F01) BET 6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560 V 11 Resistor (R319) RF-2TK5R6 5.6 , 2 W 12 Louver motor MP24Z 12VDC 13 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 3-48VDC 14 Relay (Fan, RY03) G5NB-1A Rating 3A/AC250 V, 12VDC 15 Relay (Solenoide, RY04) G5NB-1A Rating 3A/AC250 V, 12VDC
µRM1260V
W
DC 390V, Secondary DC 12V
W
10k at 25 C
W
°
°
°
4-2. Outdoor Unit (RAS-13UAH-E4)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor PH225X2C-4FT Winding resistance ( ) C-R C-S
°
(at 20 C) 2.35 3.22 Output (Rated) 42 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
2 Fan motor (for outdoor) HF-240-42A Winding resistance ( ) Red-Black White-Black
°
(at 20 C) 176.2 290.5
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
DS451155BPQC AC 450 V, 1.5mF
DS371356CPNB AC 370 V, 35mF
W
W
- 18 -
FILE NO. SVM-05001
4-3. Outdoor Unit (RAS-10UAH-E4)
No. Parts name Type Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor PH180X1C-4DZDN3 Winding resistance ( )
°
(at 20 C) 3.33 3.78 Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
Winding resistance ( ) Red-Black White-Black
°
(at 20 C
2 Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor 4
(for compressor)
HF-240-20B or
SKF-240-20B
DS451155BPQC AC 450 V, 1.5mF
DS371306CPNB AC 370 V, 30mF
W
W
387.3 or 235.2 466.2 or 260.1
C-R C-S
5 Overload relay JMRA99269-9200 U/T : 6.8A (90
°
C), OPEN : 135±5 C, CLOSE : 69±11 C
° °
4-4. Outdoor Unit (RAS-07UAH-E4)
No. Parts name Type Specifications
Output (Rated) 605W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PH108X1C-4DZDN2 Winding resistance () C-R C-S
(at 20°C) 4.84 4.40
2 Fan motor (for outdoor)
Running capacitor 3
(for fan motor)
Running capacitor 4
(for compressor)
5 Overload relay JMRA99208-9201 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
HF-240-20B or SKF-240-20B
DS451155BPQC AC 450V, 1.5µ F
DS371256CPNB AC 370V, 25µ F
Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz
Winding resistance () Red-Black White-Black
(at 20°C)
387.3 or 235.2
466.2 or 260.1
- 19 -
FILE NO. SVM-05001
4-5. Indoor Unit (RAS-13UKP-E4, RAS-10UKP-E4, RAS-07UKP-E4, RAS-13UKPX4,
RAS-10UKPX4, RAS-12UKPX4, RAS-07UKPX4)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF- 220-20-4A-1 AC Motor with 150 C thermo fuse 2 Thermo sensor (TA-sensor) 10k at 25 C 3 Transformer 4 Microcontroller unit (IC30) TMP87CM40AN 5 Heat exchanger sensor
(TC-sensor) 6 Line filter (L01) *SS11V-06270 27mH, 600mA 7 Bridge rectifier (DB50) KBP06M/51 1.5A, 600 V 8 Capacitor (C50) PF1E222MNN1625 2200mF, 25 V 9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560 V
11 Louver motor MP24Z 12VDC 12 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 3~48VDC
TT-10
W
10k at 25 C
W
°
°
°
4-6. Outdoor Unit (RAS-13UA-E4)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor
2 Fan motor (for outdoor) HF-240-30B Winding resistance (W) Red-Black White-Black
Running capacitor
3
Running capacitor
4
(for compressor)
PH225X2C-4FT
DS451155BPQC AC 450 V, 1.5µF
DS371356CPNB AC 370 V, 35 F
Winding resistance (W) C-R C-S
°
(at 20 C) 2.35 3.22 Output (Rated) 30 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
°
(at 20 C) 245 388
m
- 20 -
FILE NO. SVM-05001
4-7. Outdoor Unit (RAS-13UAX4, RAS-12UAX4)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor Winding resistance (W) C-R C-S
2 Fan motor (for outdoor) HF-240-30B Winding resistance (W) Red-Black White-Black
Running capacitor
3
(for fan motor) Running capacitor
4
(for compressor)
PH225X2C-4FT
(at 20°C) 2.35 3.22 Output (Rated) 30 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
(at 20°C) 245 388
DS451155BPQC AC 450 V, 1.5 F
DS371356CPNB AC 370 V, 35 F
m
m
4-8. Outdoor Unit (RAS-10UA-E4, RAS-10UAX4)
No. Parts name Type Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
1 Compressor RM5510GNE94 Winding resistance (W) C-R C-S
(at 20°C) 3.710 4.099 Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz Winding resistance (W) Red-Black White-Black (at 20°C)
m
m
U/T : 6.1A (80°C), OPEN : 135±5°C, CLOSE : 78±11°C
387.3 or 235.2
466.2 or 260.1
2 Fan motor (for outdoor)
Running capacitor
3
(for fan motor) Running capacitor
4
(for compressor)
Overload relay
5
LPAP960B
HF-240-20B or SKF-240-20B
DS451155BPQC AC 450 V, 1.5 F
DS371256CPNB AC 370 V, 25 F
- 21 -
FILE NO. SVM-05001
4-9. Outdoor Unit (RAS-07UAX4)
No. Parts name Type Specifications
Output (Rated) 605W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor Winding resistance () C-R C-S
2 Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5 Overload relay JMRA99208-9201 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
PH108X1C-4DZDN2
(at 20°C) 4.84 4.40
Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz
HF-240-20B or SKF-240-20B
DS451155BPQC AC 450V, 1.5µF
DS371256CPNB AC 370V, 25µF
Winding resistance () Red-Black White-Black
(at 20°C) 387.3 or 235.2 466.2 or 260.1
4-10. Outdoor Unit (RAS-07UA-E4)
No. Parts name Type Specifications
Output (Rated) 605W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PH108X1C-4DZDN2 Winding resistance () C-R C-S
(at 20°C) 4.84 4.40
Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor) Winding resistance () Red-Black White-Black
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5 Overload relay JMRA99208-9201 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
HF-240-20B or SKF-240-20B
DS451155BPQC AC 450V, 1.5µF
DS371256CPNB
(at 20°C)
AC 370V, 25µF
387.3 or 235.2 466.2 or 260.1
22
5. REFRIGERATION CYCLE DIAGRAM
5-1. RAS-13UKHP-E4 / RAS-13UAH-E4
FILE NO. SVM-05001FILE NO. SVM-05001
Indoor unit
Cooling
0.39 m (Connecting pipe)
Æ12.7
O.D.:12.7 mm O.D.:6.35 mm
Cooling
Heating
Heating
P
Packed valve
(Æ12.7)
Heating
4-way valve
Cooling
Compressor
PH225X2C-4FT
Accumulator
Heat exchanger
Cross flow fan
T1
Capillary tube Æ1.5 x 900
Packed valve
(Æ6.35)
Capillary tube
Æ1.0 x 800
l
0.49 m (Connecting pipe)
Æ6.35
l
Heat exchanger
Refrigerant R22 : 1.00 kg.
Cooling Heating
Propeller fan Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 1.84 46.0 High 20/15 7/6
Heating Overload*1 2.00 ~ 2.42 52.0 ~ 59.0 Low 27/- 24/18
Low temperature 1.50 38.0 High 20/
-
-10/-10
Standard 0.49 10.0 High 27/19 35/24
Cooling Overload 0.60 15.0 High 32/23 43/26
Low temperature 0.45 2.0 Low 21/15 21/15
Note
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
·
·
*1 During heating overload operation, a value for the high temperature limit control operation is included.
- 23 -
5-2. RAS-10UKHP-E4 / RAS-10UAH-E4
FILE NO. SVM-05001
Indoor unit
Cooling
0.39 m (Connecting pipe) Æ9.52
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Heating
Heating
P
Packed valve
(Æ9.52)
Heating
4-way valve
Cooling
Compressor
PH180X1C-4DZDN3
Accumulator
Heat exchanger
Cross flow fan
T1
0.49 m (Connecting pipe) Æ6.35
Packed valve
(Æ6.35)
Capillary tube
Æ1.5 x 1000l
Heat exchanger
Refrigerant R22 : 0.76 kg.
Cooling
Heating
Propeller fan Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger inter changing
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 1.65 40.0 High 20/15 7/6
Heating Overload*1 2.00 ~ 2.40 52.0 ~ 59.0 Low 27/- 24/18
Low temperature 1.40 35.0 High 20/-
-10/-10
Standard 0.50 12.0 High 27/19 35/24
Cooling Overload 0.60 15.0 High 32/23 43/26
Low temperature 0.48 5.0 Low 21/15 21/15
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
*1 · During heating overload operation, a value for the high temperature limit control operation is included.
- 24 -
5-3. RAS-07UKHP-E4 / RAS-07UAH-E4
FILE NO. SVM-05001
Indoor unit
Cooling
0.39m (Connecting pipe) 9.52
O.D.:9.52mm O.D.:6.35mm
Cooling
Heating
Heating
P
Packed valve
(9.52)
Heating
4-way valve
Cooling
Compressor
PH108X1C-4DZDN2
Accumulator
Heat exchanger
Cross flow fan
T1
0.49m (Connecting pipe) 6.35
Packed valve
(6.35)
Capillary tube
1.0x900S
(2 pcs.)
Heat exchanger
Refrigerant R-22 : 0.60 kg.
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Cooling Heating
50Hz
Propeller fan Outdoor unit
Standard
pressure P
(MPaG)
Mark( )means check points of Gas Leak.
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Standard 1.32 33.0 High 20/– 7/6
Heating Overload 1.69 49.0 Low 27/– 24/18
Low temperature 1.10 30.0 High 20/––10/–10 Standard 0.59 12.0 High 27/19 35/24
Cooling Overload 0.68 16.0 High 32/23 43/26
Low temperature 0.50 2.0 Low 21/15 21/15
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
25
5-4. RAS-13UKP-E4 / RAS-13UA-E4
RAS-13UKPX4 / RAS-13UAX4 RAS-12UKPX4 / RAS-12UAX4
FILE NO. SVM-05001
Indoor unit
Cooling
0.39 m (Connecting pipe) Æ12.7
O.D.:12.7 mm O.D.:6.35 mm
Cooling
Packed valve
Cooling
P
(Æ12.7)
Compressor
PH225X2C-4FT
Heat exchanger
Cross flow fan
T1
Packed valve
(Æ6.35)
Capillary tube Æ1.7 x 1000
0.49 m (Connecting pipe) Æ6.35
l
Heat exchanger
Refrigerant R22 : 0.80 kg.
Cooling
Propeller fan
Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.48 9.0 High 27/19 35/24
Cooling Overload 0.59 15.0 High 32/23 43/26
Low temperature 0.45 2.0 Low 21/15 21/15
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
− 26
5-5. RAS-10UKP-E4 / RAS-10UA-E4
RAS-10UKPX4 / RAS-10UAX4
FILE NO. SVM-05001
Indoor unit
Cooling
0.39 m (Connecting pipe) Æ9.52
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Packed valve
Cooling
P
(Æ9.52)
Compressor
RM5510GNE94
Heat exchanger
Cross flow fan
T1
0.49 m (Connecting pipe) Æ6.35
Packed valve
(Æ6.35)
Capillary tube Æ1.5 x 1100l
Heat exchanger
Refrigerant R22 : 0.68 kg.
Cooling
Propeller fan Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.54 13.0 High 27/19 35/24
Cooling Overload 0.65 17.0 High 32/23 43/26
Low temperature 0.48 5.0 Low 21/15 21/15
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
− 27