7-1Outline of Air Conditioner Control
7-2Description of Operation Circuit
7-3Hi POWER Mode
7-4High-Temperature Limit Control
7-5Low-Temperature Limit Control
7-6Defrost Operation
7-7Current Limit Control
7-8Auto Restart Function
7-9Filter Check Lamp
7-10 Self-Cleaning function
- 1 -
8.INSTALLATION PROCEDURE
8-1Safety Cautions
8-2Installation Diagram of Indoor and Outdoor Units
8-3Installation
8-4Indoor Unit
8-5Outdoor Unit
8-6How to Set Remote Control Selector Switch
8-7Others
9.TROUBLESHOOTING CHART
9-1Troubleshooting Procedure
9-2Basic Check Items
9-3Primary Judgement
9-4Self-Diagnosis by Remote Control (Check Code)
9-5Troubleshooting Flowcharts
9-6Troubleshooting for Remote Control
10. PART REPLACEMENT
10-1 Indoor Unit
10-2 Outdoor Unit
FILE NO. SVM-04050
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy)
11-2 Indoor Unit
11-3 Outdoor Unit (RAS-10UA-E3-1, RAS-10UAX3-1)
11-4 Outdoor Unit (RAS-07UAH-E3-1)
11-5 Outdoor Unit (RAS-07UAX3-1, RAS-07UA-E3-1)
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150 C thermo fuse
2Thermo sensor (TA-sensor)10k at 25 C
3Switching transformer (T01)SWT-47
4Microcontroller unit (IC30)TMP87CM40AN
5Heat exchanger sensor
(TC-sensor)
6Line filter (L01)LC*SS11V-0627027mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8Capacitor (C02)KMH400VSSN47M22S47mF, 400 V
9Fuse (F01)TSCR6.3AT6.3A, 250VAC
4-3. Indoor Unit (RAS-10UKP-E3, RAS-07UKP-E3, RAS-10UKPX3, RAS-07UKPX3)
No.Parts nameTypeSpecifications
1 Fan motor (for indoor) SKF- 220-20-4A-1 AC Motor with 150 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Switching transformer
4 Microcontroller unit (IC30) TMP87CM40AN
5Heat exchanger sensor
This is a fixed capacity type air conditioner, which uses
AC motor for an indoor fan. The AC motor drive
circuit is mounted in the indoor unit. And electrical
parts which driving the compressor and the outdoor
fan motor, are mounted in the outdoor unit.
The air conditioner is controlled by the controller
mounted in the indoor unit. The controller operates all
components based on the commands transmitted from
the remote control and the feedback data of the sensor
is as follow:
• The temperature measurement at the air inlet of
the indoor heat exchanger by the indoor
temperature sensor
•The temperature measurement at the indoor
heat exchanger by the indoor heat exchanger
temperature sensor
• Indoor fan motor operation control
• Louver motor control
• LED display control
• Outdoor fan motor operation control
• Compressor operation control
• Receiving the information of the operation
status and judging the information or the
indication of errors
7-1-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically
controlled according to the operation mode.
Besides, position of vertical air flow louver can be
arbitrarily set by pressing [FIX] button.
The louver position which is set by [FIX] button is
stored in the microcontroller, and the louver is
automatically set at the stored position for the next
operation.
(2) Swing
If [SWING] button is pressed when the indoor unit
is in operation, the vertical air flow louver starts
swinging. When [FIX] button is pressed, it stops
swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED
and HIGH). If AUTO mode is selected, the fan
motor speed is automatically controlled by the
difference between the preset temperature and
the room temperature.
LOW
=
LOW+MED
+
2
MED+=
MED+HIGH
2
+
OPERATION
MODE
RAS-07UK Series
RAS-07UKH Series
Model
RAS-10UK Series
Table 7-1-1
FAN TA P
CoolingUHHMLL-ULSL
Fan onlyHMLL-
DryMLL-ULSL
Heat UHHMLL-ULSL
rpm 1350 1200 1050 1000 950 900 800 750 700 650
Air flow volume (m
rpm
Air flow volume (m3/h)
rpm
Air flow volume (m3/h)
3
/h) 650 570
1300
630
1350
1300
630
1250
610
1250 1050 1000 950 900 800 750 700 650
610 490 460 430 400 340 310 280 250
650
1200
570
1300
630
460 430 400 340 310 280 250
490
1050
490
1000
460
900
400
800
340
750
310
700
280
650
250
− 19 −
FILE NO. SVM-04050
7-2. Description of Operation Circuit
(1) When turning on the breaker, the operation lamp
blinks. This means that the power is on (or the
power supply is cut off.)
(2) When pressing [START / STOP] button on the
remote control, receiving beep sounds from the
indoor unit, and the next operation is performed
together with opening the vertical air flow louver.
(3) Once the operation mode is set, it is memorized in
the microcontroller so that the previous operation
can be effected thereafter simply by pressing
[START / STOP] button.
7-2-1. Fan only operation
([MODE] button on the remote control is set
to the fan only operation.)
(1) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-1. When
[FAN] button is set to LOW, LOW
HIGH, the motor operates with a constant air flow.
°C
+3
+2.5
+2
-
+1.5
+1
+0.5
(Room temp.) (Preset temp.)
Preset
temp.
0
(Preset temp.: 22°C)
NOTE :
*1: The values marked with *1 are calculated and
controlled by the difference in motor speed
between M+ and L-.
Fig. 7-2-1 Setting of air flow [FAN:AUTO]
(2) The Hi POWER operation cannot be set.
+
, MED, MED+ or
M+
*1
*1
*1
L
-
7-2-2. Cooling operation
([MODE] button on the remote control is set
to the cooling operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display on the remote control are
controlled as shown in Fig. 7-2-2.
°C
ONON
OFF OFFOFF ON
4-way valve
Compressor
Outdoor fan
OPERATION
-
(Room temp.) (Preset temp.)
Preset
temp.
0.5
0
Fig. 7-2-2
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-3. When
[FAN] button is set to LOW, LOW
+
, MED, MED+ or
HIGH, the motor operates with a constant air flow.
°C
(Preset temp.)
−
(Room temp.)
Preset
temp.
+3
+2.5
+2
+1.5
+1
+0.5
0
-0.5
M+
*1
*1
*1
L
-
NOTE :
*1: The values marked with *1 are calculated and
controlled by the difference in motor speed
between M+ and L-.
display
- 20 -
Fig. 7-2-3 Setting of air flow [FAN:AUTO]
FILE NO. SVM-04050
7-2-3. Dry operation
([MODE] button on the remote control is set
to the dry operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display on the remote control are
controlled as shown in Fig. 7-2-4.
°C
ON:6min.
-
(Room temp.) (Preset temp.)
Preset
temp.
+3
+2
+1
ON:6min.
OFF:4min.
ON:5min.
OFF:5min.
OFF
0
Compressor
OFF
ON:5min.
OFF
4-way valve
OFF:4min.
OFF:5min.
Outdoor fan
Fig. 7-2-4
ON
display
OPERATION
7-2-4. Heating operation (UKH Series only)
([MODE] button on the remote control is set
to the heating operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display on the remote control are
controlled as shown in Fig. 7-2-6.
°C
Preset
temp.
0
-0.5
-
(Room temp.) (Preset temp.)
ON
OFF
ON
Compressor
OFF
ON
4-way valve
Outdoor fan
Fig. 7-2-6
ON
display
OPERATION
(2) The microcontroller turns the compressor on and
off at the regular intervals (4 to 6 minutes). While
the compressor is turning off, the indoor fan motor
operates in the SUPER LOW position.
The pattern of operation depending on the relation
between room temperature and preset
temperatures is shown in Fig. 7-2-5.
Room temp.
Preset temp.+1
Preset temp.
Compressor
Outdoor fan
Indoor fan
ONONONON
OFFOFFOFF
L *SL SLLL SL L
*
Super Low
Fig. 7-2-5
(3) [FAN] button on the remote control is set to AUTO
only.
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-7. When
[FAN] button is set to LOW, LOW
+
, MED, MED+ or
HIGH, the motor operates with a constant air flow.
Preset
temp.
°C
0
-0.5
-1
-1.5
-2
-
-5.0
-5.5
[FAN AUTO]
(Room temp.) (Preset temp.)
L
*1
*2
+
M
H
*1, *2 : The values marked with *1 and *2 are
calculated and controlled by the difference in
motor speed between M+ and L.
Fig. 7-2-7 Setting of air flow [FAN:AUTO]
(4) The Hi POWER operations cannot be set.
- 21 -