Toshiba RAS-10SA-ES, RAS-10SKHP-ES, RAS-10S2AH-ES, RAS-10SKP-ES SERVICE MANUAL

SERVICE MANUAL
AIR CONDITIONER
SPLIT WALL TYPE
RAS-10SKHP-ES / RAS-10S2AH-ES
RAS-10SKP-ES / RAS-10SA-ES
FILE NO. SVM-09029
January, 2009
CONTENTS
1. SPECIFICATIONS
2. CONSTRUCTION VIEWS
2-1 Indoor Unit
2-2 Outdoor Unit
3. WIRING DIAGRAM
3-1 RAS-10SKHP-ES / RAS-10S2AH-ES
3-2 RAS-10SKP-ES / RAS-10SA-ES
4. SPECIFICATION OF ELECTRICAL PARTS
4-1 Indoor Unit (RAS-10SKHP-ES) 4-2 Outdoor Unit (RAS-10S2AH-ES) 4-3 Indoor Unit (RAS-10SKP-ES)
4-4 Outdoor Unit (RAS-10SA-ES)
5. REFRIGERATION CYCLE DIAGRAM
5-1 RAS-10SKHP-ES / RAS-10S2AH-ES 5-2 RAS-10SKP-ES / RAS-10SA-ES
6. CONTROL BLOCK DIAGRAM
6-1 RAS-10SKHP-ES / RAS-10S2AH-ES 6-2 RAS-10SKP-ES / RAS-10SA-ES
7. OPERATION DESCRIPTION
7-1 Remote control 7-2 Outline of Air Conditioner Control 7-3 Description of Operation Mode 7-4 High-Temperature Limit Control 7-5 Low-Temperature Limit Control 7-6 Defrost Operation 7-7 Current Limit Control 7-8 One-Touch Comfort 7-9 Hi POWER Mode 7-10 QUIET Mode 7-11 ECO Operation
7-12 COMFORT SLEEP mode 7-13 FILTER Check lamp 7-14 Auto Restart Function
7-15 Self-Cleaning function
- 1 -
8. INSTALLATION PROCEDURE
8-1 Safety Cautions 8-2 Installation Diagram of Indoor and Outdoor Units 8-3 Installation 8-4 Indoor Unit 8-5 Outdoor Unit 8-6 How to Set Remote Control Selector Switch 8-7 Others
9. TROUBLESHOOTING CHART
9-1 Troubleshooting Procedure 9-2 Basic Check Items 9-3 Primary Judgement 9-4 Self-Diagnosis by Remote Control (Check Code) 9-5 Troubleshooting Flowcharts
9-6 Troubleshooting for Remote Control
10. PART REPLACEMENT
10-1 Indoor Unit 10-2 Outdoor Unit
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy) 11-2 Indoor Unit
11-3 Outdoor Unit (RAS-10S2AH-ES) 11-4 Outdoor Unit (RAS-10SA-ES)
- 2 -

1. SPECIFICATIONS

MODEL
ITEM Cooling Heating Cooling
Capacity
Power source V 220 240
Power consumption kW 0.83 0.85 0.79 0.82 0.83 0.85
Power factor % 98 97 97 96 98 97
Running Indoor A 0.15 current Outdoor A 3.71 3.50 3.55 3.40 3.71 3.50
Starting current A 18
Moisture removal lit/h 1.2
Noise
Refrigerant
Refrigerant control Capillary tube
Interconnection
pipe
Indoor (H/M+/M/L+/L)
Outdoor (220-240V) dB 47 49 47 49 46 47
Name of refrigerant R410A Rated amount kg 0.78
Gas side size mm ∅ 9.52
Connection type Flare connection
Liquid side size mm ∅ 6.35
Connection type Flare connection
Maximum length (One way)
Maximum height difference
kW 2.73 2.73 2.92 2.96 2.73 2.73
Phase 1
Hz 50
dB
m 10*
m 5
RAS-10SKHP-ES / RAS-10S2AH-ES
220V 240V 220V 240V 220V 240V
39/37/35/33/31
1
RAS-10SKP-ES / RAS-10SA-ES
0.72
INDOOR UNIT
Height mm 250
Dimensions Width mm 740
Depth mm 195
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m3/h 540 560 540
Air volume Medium fan m3/h 460 500 460
Low fan m3/h 390 400 390
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10S2AH-ES RAS-10SA-ES
Height mm 550
Dimensions Width mm 780
Depth mm 290
Net weight kg 31 30
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 2030 2150 2030 2150 1740 1850
Fan motor output W 30 20
Compressor
Safety device Fuse, Overload relay
Louver type Automatic louver Usable outdoor temperature range °C 15 ~ 43 10 ~ 24 15 ~ 43
Model PA108X1C-4FZDN
Output W 750
RAS-10SKP-ESRAS-10SKHP-ES
3
Note : 1
·
Capacity is based on the following temperature conditions.
FILE NO. SVM-09029
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Note : 2
*1 No need to change extra refigerant.
Condition
Cooling Heating
(DB) 27°C20°C
(WB) 19°C15°C
(DB) 35°C7°C
(WB) 24°C6°C
JIS C9612
- 4 -
2-1. Indoor Unit
FILE NO. SVM-09029

2. CONSTRUCTION VIEWS

Front panel
60
8
Knock out system
252
50
Air inlet
Air filter
739
Air outlet
Heat exchanger
195
58
52
8
Knock out system
50
6055
5560
133.41499104.39
56
Wireless remote controller
157
19
125
Drain hose (0.5m)
290
Hanger
606
235
215
235
215
Hanger
45.9
250
90 135
Hanger
145
145
Hanger
Installation plate outline
Center line
Remote controller holder
Connecting pipe (0.37m) (Flare ∅
6.35)
Connecting pipe (0.37m) (Flare ∅
9.52)
For stud bold (
For stud bold (∅
26.6
45.9164.1
40
38
90135
63
8~
10)
26
6)
5
2.2. Outdoor Unit
600
50
36
320
306
A detail Drawing (Back leg)
R5.5
R
Ø
15
6 hole
28
86
320
Ø
25 Drain outlet
FAN-GUARD
436
Ø
FILE NO. SVM-09029
A
108 125
306
320
Ø
2
-
Ø
11 x 14
(For 8 -
Ø
Hole
10 anchor bolt)
Ø
6 hole
11x14 hole
Ø
B Detail Drawing (Front leg)
36 50
R
15
COVER-PV
Z
290
550
45 or more
275
320 342
Electrical part cover
Liquid side (Flare 6.35)
Ø
Gas side (Flare 9.52)
Ø
5
4
S
ervice port
-Ø 10 anchor bolt)
Ø
Z View
600
Air intlel
9060090
69
129
84
2
-R5- 5x17L UShape (For 8
320
100 or more
Air outlel
400 or more
Installation dimension
6
600 or more
2- 11x14 Long holes(For 8 - 10 anchor bolt)
Ø
Ø
Ø

3. WIRING DIAGRAM

3-1. RAS-10SKHP-ES / RAS-10S2AH-ES
BRW
L
BLU
N
GRN & YEL
SINGLE PHASE 220-240V 50/60Hz
BLK
WHI
BLK P04
CN31
T02
C.T.
1 1
3 3
CN27
CN03
1 1
BLK
2 2
BLK
SENSOR (TA)
SG01
DSA
BLK
THERMO
PINK
1 1
R22
VARISTOR
3
4
RY03
73 C x2
THERMAL FUSE
PINK
2
CN04
2
T6.3A 250VAC
RY01
CN01
2
1
HEAT EXCHANGER
2
1
BLK
BLK
SENSOR (TC)
RY04
CR02
CR01
LOUVER MOTOR
YEL
5 5
R
1
STO
C01
R2
VARI
MAIN P.C. BOARD WP-015
INFRARED RAYS RECEIVE
AND INDICATION PARTS
CN25
BLU
WHI
YEL
YEL
YEL
34
2
1
34
2
1
CN07
DC5V
Voltage Regulator
C02
L01
145 C
1 1 2 2 3 3
4 4
5 5
AC FAN MOTOR
BLU
IC35
CN10
66
321 321
BLU
321 321
C15
BLK GRY YEL
BRW
RED
WHI
54 8 54 8
BLU
BLU
54 8 54 8
R319
5 5
6
7
6
7
WHI
BLU
BLU
6
7
CN14
6
7
Micro Power Module
DC12V
+
C63
DB01
3 3
CN11
21 3
1
21 3
1
INDOOR TERMINAL BLOCK
OUTDOOR TERMINAL BLOCK
OVER LOAD RELAY
COMPRESSOR
BLK
BLK
PNK
WHI
BLK
1
(L)2(N)
1
RED
WHI
2
BLU
SOLENOID COIL
RED
RED
CAPACITOR
RED
3
3
BLU
CAPACITOR
FAN MOTOR
BLU
4
4
WHI BLK
7
INDOOR
OUTDOOR
CHASSIS
3-2. RAS-10SKP-ES / RAS-10SA-ES
FILE NO. SVM-09029
POWERSUPPLY (Frommainline) 1220‑240V
50Hz
Heatexchanger Sensor(TC)
Thermosensor(TA)
CN25
1 2 3 4 5 6 7 8
andindicationparts.
Infraredraysreceiver
WP‑017
GRN&YEL
Heatexchanger
BLU
1
BLU
2
BLU
3
BLU
4
BLU
5
BLU
6
BLU
7
WHI
8
CN01
1
22
CN03
1 2
CN12
1 2
3 4 5 6 7 8
BRW
L
BLU
N
GRN&YEL
1
6.3A
1 2
1 2 3 4
5 6 7 8
250VAC
R62
WHI
BLK
CN31
4
RY01
F01
R63
21
C25
3
BLK P04
3
SG01
DSA
C26
L01
4
DB01
R64
C27
Switchingpowersupply
DC5V
Voltageregulator
12V
3
4
MCU
IC03
WP‑018
1
2
CN04
11 22
DC12V
PNK
PNK
CN07
WHI
1
1
YEL
22
YEL
3
3
YEL
44
YEL
55
CN11
YEL
1
1
GRY
2
2
BRW
3
3
C07
CN10
WHI
5
5
BLK
33
RED
1
1
o
Tempfuse73Cx2
1 22 3 44 55
1
3
Louvermotor
1
1
2
2
3
3
ACmotor
4
4
565
6
Fanmotor
INDOOR
TERMINAL
BLOCK
1
BLK
OUTDOOR
TERMINAL
BLOCK
1(L)
BLK
BLK
FAN MOTOR
OVERLOAD RELAY
RED
2
WHI
2(N)
COMPRESSOR
RED WHI
GRN&YEL
CHASSIS
RED
CAPACITOR
INDOOR
OUTDOOR
CAPACITOR
RED WHI
8

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-10SKHP-ES)
No. Parts name Type Specifications
1 Fan motor (for indoor) AFN-220-20-4D AC Motor with 145 °C thermo fuse 2 Thermo sensor (TA-sensor) 10k at 25 C 3 Micro power module (M01) RM1260V 4 Microcontroller unit (IC30) TMP87CM40AFG-6P69 5 Heat exchanger sensor
(TC-sensor) 6 Line filter (L01) 7 Bridge rectifier (DB01) DB105G 1A, 600 V
8 Capacitor (C63) EKMH401VSN470MP20S 47mmF, 400 V
9 Fuse (F01) BET6.3A 6.3A, 250VAC
10 Varistor (R21, R22) 11 Resistor (R319) RF-2TK5R6 5.6 , 2 W 12 Louver motor 13 Relay (Comp., RY01) G4A-1A-E-CA Rating 20A/AC250 V, 12VDC 14 Relay (Fan, RY03) 15 Relay (Solenoide, RY04) G5NB-1A Rating 3A/AC250 V, 12VDC
LC*SS11V-R06270
SR561K14DL
MP24ZCT
G5NB-CA
W
W
10k at 25 C
27mH, 600mA
560 V
W
12VDC
Rating 3A/AC250 V, 12VDC
°
°
4-2. Outdoor Unit (RAS-10S2AH-ES)
No. Parts name Type Specifications
Output (Rated) 750W , 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA108X1C-4FZDN Winding resistance (Ω) C-R C-S
(at 20°C) 3.75 4.75
Output (Rated) 30W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor) Winding resistance () Red-Black White-Black
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Overload relay
WLF-240-30A
(at 20°C)
DS451155NPQB AC 450V~, 1.5µ
RS44B256U0213S
LPAP960B
AC 440V~, 25
AC 220 240V
U/T: 6.1A(80°C), Open: 135±5°C, Close: 78±11°C
µF
237
F
380
- 9 -
FILE NO. SVM-09029
4-3. Indoor Unit (RAS-10SKP-ES)
No. Parts name Type Specifications
1 Fan motor (for indoor) AFN-220-20-4D AC Motor with 145 °C thermo fuse 2 Thermo sensor (TA-sensor) 10k at 25 C 3 Switching transformer 4 Microcontroller unit (IC30) TMP87CM40ANG-6P68 5 Heat exchanger sensor
(TC-sensor) 6 Line filter (L01) LC*SS11V-R06270 27mH, 600mA
7 Capacitor (C27) EKMH401VSN470MP20S 47mF, 400 V 8 Fuse (F01) BET6.3A 6.3A, 250VAC
9 Varistor (R62, R63) SR561K14DL
10 Resistor (R64) 11 Louver motor MP24ZCT 12VDC 12 Relay (Comp., RY01) G4A-1A-E-CA Rating 20A/AC250 V, 12VDC
ST-02
RF-2TK5R6
W
W
10k at 25 C
560 V
W
5.6 , 2 W
°
°
4-4. Outdoor Unit (RAS-10SA-ES)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA108X1C-4FZDN Winding resistance (Ω) C-R C-S
(at 20°C) 3.75 4.75
Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor) Winding resistance (Ω) Red-Black White-Black
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay
SKF-240-20B
(at 20°C)
DS451155NPQB
B32332I5256J063
LPAP960B
AC 450V~,1.5 µF
AC 450V~,25
U/T: 6.1A(80°C), Open: 135±5°C, Close: 78±11°C
235.2 260.1
µF
10

5. REFRIGERATION CYCLE DIAGRAM

5-1. RAS-10SKHP-ES / RAS-10S2AH-ES
Indoor unit
Cooling
0.39m (Connecting pipe) 9.52
O.D.:9.52mm O.D.:6.35mm
Cooling
Heating
Heating
P
Packed valve
(9.52)
Heating
4-way valve
Cooling
Compressor
PA108X1C-4FZDN
Accumulator
Heat exchanger
Cross flow fan
T1
Capillary tube
1.5x1000
Packed valve
(6.35)
Capillary tube
1.5x1200
l
0.49m (Connecting pipe) 6.35
l
Heat exchanger
Refrigerant R410A : 0.78 kg.
Cooling Heating
Propeller fan Outdoor unit
Mark( )means check points of Gas Leak.
Ambient temp.
50Hz
Standar d
pressure
(MPaG)
P
Surface temp. of heat
exchanger inter changing
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 2.95 43.5 High 20/15 7/6
Heating Overload 3.70 57.0 Low 27/ 24/18
Low temperature 2.40 32.0 High 20/
10/10
Standard 0.93 10.5 High 27/19 35/24
Cooling Overload 1.08 15.0 High 32/23 43/26
Low temperature 0.69 2.0 Low 21/15 21/15
Note :
 Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
11
5-2. RAS-10SKP-ES / RAS-10SA-ES
Indoor unit
Cooling
0.39m (Connecting pipe) 9.52
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
Cooling
P
(9.52)
Compressor
PA108X1C-4FZDN
Heat exchanger
Cross flow fan
T1
0.49m (Connecting pipe) 6.35
Packed valve
(6.35)
Capillary tube
1.5x1100l
Heat exchanger
Refrigerant R410A : 0.72 kg.
Cooling
Propeller fan Outdoor unit
Mark( )means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.95 10.5 High 27/19 35/24
Cooling Overload 1.12 16.0 High 32/23 43/26
Low temperature 0.71 2.0 Low 21/15 21/15
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
12

6. CONTROL BLOCK DIAGRAM

6-1. RAS-10SKHP-ES / RAS-10S2AH-ES
FILE NO. SVM-09029
Heat Exchange sensor
Thermo. Sensor
Current Sensor
(Compressor Current)
Infrared Rays Signal Reciver
Main Unit Control Panel
Functions
 Louver Control
3-minutes Delay at Restart
for Compressor
Initiallizing Circuit
Clock Frequency Oscillator Circuit
Power Supply
Circuit
Noise Filter Relay Driver, Louver Driver
Motor Revolution Control
Processing
(Temperature Processing)
Timer
Compressor
ON/OFF
Signal
Outdoor Fan
M.C.U.
ON/OFF
Signal
4-Way Valve
ON/OFF
Signal
Operation
Display
Timer
Display
Indoor Fan
Motor
Louver
ON/OFF
Signal
Louver
Motor
220-240 V~, 50Hz
REMOTE CONTROL
Relay
RY01
Compressor 4-Way Valve
Remote Control
Operation ( )
Operation Mode Selection
AUTO, COOL, DRY, HEAT, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Relay
Outdoor Fan Motor
RY03
Infrared Rays
Relay
RY04
Hi power
Filter Reset
13
6-2. RAS-10SKP-ES / RAS-10SA-ES
Main Unit Control Panel M.C.U.
Heat Exchange sensor
Functions
FILE NO. SVM-09029
Operation
Display
Thermo. Sensor
Infrared Rays Signal Reciver
 Louver Control
3-minutes Delay at Restart
for Compressor
Initiallizing Circuit
Clock Frequency Oscillator Circuit
Power Supply
Circuit
Noise Filter Relay Driver, Louver Driver
Motor Revolution Control
Processing
(Temperature Processing)
Timer
Compressor
ON/OFF
Signal
Relay
RY01
Timer
Display
Indoor Fan
Motor
Louver
ON/OFF
Signal
Louver
Motor
220-240 V~, 50Hz
REMOTE CONTROL
Compressor, Outdoor Fan Motor
Infrared Rays
Remote Control
Operation ( )
Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Hi power
Filter Reset
- 14 -

7. OPERATION DESCRIPTION

7-1. Remote control
7-1-1. Function of Push Putton
11 Infrared signal emitter
1
11
2
Start/Stop button
3
Mode select button (MODE)
4
Temperature button (TEMP)
5
Fan speed button (FAN)
6
Swing louver button (SWING)
7
Set louver button (FIX)
8
On timer button (ON) Off timer button (OFF)
9
18
10
Sleep timer button (SLEEP)
19
Timer setup button (SET)
11 12
20
Timer clear button (CLR)
13
Memory and Preset button (PRESET)
14
One Touch button (ONE-TOUCH)
15
High power button (Hi-POWER)
16
Economy button (ECO)
17
Quiet button (QUIET)
18
Comfort sleep button (COMFORT SLEEP)
19
Filter reset button (FILTER)
Clock Reset button (CLOCK)
20 21
Check button (CHK)
13
14
17
10 21
19
1
TOSHIBA
PRESET
ONE-TOUCH
2
QUIET
SWING
FIX Hi-POWER ECO
6 7
8
TIMER
SLEEP
CHK
ON
FILTER
TEMP
OFF
COMFORT
CLOCK
FAN
MODE
SLEEP
5
4
3
18
15 16
CLR
12
9
SET
11
20
15
7-1-2. Display of Remote Control
All indications, except for the clock time indicator, are displayed by pressing the button.
1. Transmission mark
This transmission mark remote controller transmits signals to the indoor unit.
indicates when the
2. Mode indicator
Indicates the current operation mode. (AUTO : Automatic control, A : Auto changeover control,
: Cool, : Dry, : Heat, : Fan only)
3. Temperature indicator
Indicates the temperature setting. (17°C to 30°C)
4. FAN speed indicator
Indicates the selected fan speed. AUTO or five fan speed levels
(
LOW , LOW+ , MED , MED+ , HIGH ) can be shown. Indicates AUTO when the operating mode is
either AUTO or
: Dry.
5. TIMER and clock time indicator
The time setting for timer operation or the clock time is indicated.
The current time is always indicated except during TIMER operation.
6. Hi-POWER indicator
Indicates when the Hi-POWER operation starts. Press the Hi-POWER button to start and press it
again to stop the operation.
7. (PRESET) indicator
Flashes for 3 seconds when the PRESET button is pressed during operation.
The button for more than 3 seconds while the mark is
flashing. Press another button to turn off the mark.
mark is shown when holding down the
8. ECO indicator
Indicates when the ECO is in activated. Press the ECO button to start and press it again
to stop operation.
9. A, B change indicator remote controller
When the remote controller switching function is set, “B” appears in the remote controller display. (When the remote controller setting is “A”, there is no indication at this position.)
11
10
10. Comfort sleep
Indicates when comfort sleep is activaled. Press comfort sleep bu
9
15
1
2
13
11. Quiet
Indicates when quiet is activated. Press quiet button to start and press it again to stop operation.
tton to selectter
12. One-Touch
Indicates when one touch comfort is activated. Press one-touch button to start the operation.
13. Swing
Indicates when louver is swing. Press swing button to start the swing operation and press it again to stop the swing operation.
8
6
3
7
4
5
16
7-2. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses a AC motor for an indoor fan. The AC motor drive circuit is mounted in the indoor unit. And electrical parts which operate the compressor and the outdoor fan motor, are mounted in the outdoor unit. The air conditioner is mainly controlled by the indoor unit controller. The controller operates the indoor fan motor based upon commands transmitted by the remote control and transfers the operation commands to the outdoor unit controller. The outdoor unit receives operation commands from the indoor unit, and operates the outdoor fan motor
and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation commands from the remote control and executes them.
Temperature measurement at the air inlet of the
indoor heat exchanger by the indoor
temperature sensor
Temperature measurement of the indoor heat
exchanger by the heat exchanger sensor
Louver motor control
Indoor fan motor operation control
LED display control
Transferring of operation commands to the
outdoor unit
Receiving of information of the operation status
and judging of the information or indication of error
(2) Role of outdoor unit controller
The outdoor unit controller receives the operation commands from the indoor controller and executes them.
Compressor operation
control
Operation control of
outdoor fan motor
Operations according
to the commands from the indoor unit
Turning off the compressor and outdoor fan
when the outdoor unit receives the shutdown command
Defrost control in heating operation
(Temperature measurement by the indoor heat exchanger and control for the four-way valve and the outdoor fan motor) *Heat pump Model only
7-2-1. Louver control
(1) Vertical air flow louver
Position of veritcal air flow louver is automatically controlled according to the operation mode. Besides, position of vertical air flow louver can be arbitrarily set by pressing [FIX] button. The louver position which is set by [FIX] button is stored in the microcomputer, and the louver is automatically set at the stored position for the next operation.
(2) Swing
If [SWING] button is pressed when the indoor unit is in operation, the vertical air flow louver starts swinging. When [SWING] button is pressed, it stops swinging.
7-2-2. Indoor Fan Control
The operation controls the fan speed at indoor unit side. The indoor fan (cross flow fan) is operated by the phase control induction motor. The fan rotates in 5 stages in MANUAL model, and in 5 stages in AUTO mode, respectively. (Table 7-2-1)
1) When setting the fan speed to L, L+, M, M+ or H on the remote controller, the operation is performed with the constant speed shown in Fig. 7-2-1 and
Fig 7-2-2
Fig (7-2-1) Cooling Fig (7-2-2) Heating
Indication
L L+
M M+
H
Fan speed
Low
(L + M) / 2
Med
(M + H) / 2
High
Indication
L L+
M M+
H
Fan speed
(L + M) / 2
(M + H) / 2
Low
Med
High
Table 7-2-1 Indoor fan and air flow rate
OPERATION
MODE
RAS-10SKHP-ES
Model
RAS-10SKP-ES
Cool UH H M+ M L+ L L- UL SUL Heat UH H M+ M+ L+ L L- UL SUL Dry UH H M+ M L+ L L- UL SUL fan speed (rpm) 1350 1350 1350 1300 1250 1180 1140 1000 980 980 900 800 750 700 550 Air flow (m3/h) 560 560 560 540 510 500 460 400 390 390 350 300 270 250 180 fan speed (rpm) 1350 1350 1350 1300 1250 1180 1140 1000 980 980 900 800 750 700 550 Air flow (m3/h) 560 560 560 540 510 500 460 400 390 390 350 300 270 250 180
2) When setting the fan speed to AUTO on the remote controller, revolution of the fan motor is controlled to the fan speed level shown in Table 1 according to the setup temperature, room temperature, and heat exchanger temperature.
FAN TAP
17
7-3. Description of Operation Mode
(1) When turning on the breaker, the operation lamp
blinks. This means that the power is on (or the power supply is cut off.)
(2) When pressing [ ] button on the
remote control, receiving beep sounds from the indoor unit, and the next operation is performed together with opening the vertical air flow louver.
(3) Once the operation mode is set, it is memorized in
the microcomputer so that the previous operation can be effected thereafter simply by pressing [ ] button.
7-3-1. Fan only operation
([MODE] button on the remote control is set to the fan only operation.)
(1) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-3-3. When [FAN] button is set to LOW, LOW+, MED, MED+ or HIGH, the motor operates with a constant air flow.
°C
7-3-2. Cooling operation
([MODE] button on the remote control is set to the cooling operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display lamp are controlled as shown in Fig. 7-3-4.
° C
ON ON
OFF OFF OFF ON
4-way valve
Compressor
Outdoor fan
(Room temp.) (Preset temp.)
Preset temp.
0.5
0
Fig. 7-3-4
display lamp
OPERATION
(Room temp.) (Preset temp.)
Preset temp.
+3 +2.5 +2
+1.5 +1 +0.5 0
(Preset temp.: 24 °C)
M+
NOTE1 : *1 : Fan speed = (M + − L) x 3/4 + L
*2 : Fan speed = (M + − L) x 2/4 + L *3 : Fan speed = (M + L) x 1/4 + L
(Linear approximation from M+ and L)
NOTE2 : The Hi Power, ECO and COMFORT SLEEP
operation can not be set
Fig. 7-3-3 Setting of air flow [FAN:AUTO]
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-3-5. When
*1 *2 *3
[FAN] button is set to LOW, LOW+, MED, MED+ or HIGH, the motor operates with a constant air flow.
°C
(Room temp.) (Preset temp.)
Preset temp.
+3 +2.5 +2 +1.5 +1 +0.5
0
-0.5
M+
*1 *2 *3
NOTE1 : *1 : Fan speed = (M + − L) x 3/4 + L
*2 : Fan speed = (M + − L) x 2/4 + L *3 : Fan speed = (M + L) x 1/4 + L
(Linear approximation from M+ and L)
Fig. 7-3-5 Setting of air flow [FAN:AUTO]
18
7-3-3. Dry operation
([MODE] button on the remote control is set to the dry operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display lamp are controlled as shown in Fig. 7-3-6.
° C
ON:6min.
OFF:4min.
ON
ON:5min.
OFF:5min.
OFF
4-way valve
Outdoor fan
(Room temp.) (Preset temp.)
Preset temp.
+3
+2
+1
ON:6min.
OFF:4min.
OFF
ON:5min.
OFF:5min.
OFF
0
Compressor
Fig. 7-3-6
7-3-4. Heating operation
RAS-10SKHP-ES
(1) The compressor, 4-way valve, outdoor fan and
Preset temp.
display lamp
OPERATION
([MODE] button on the remote control is set to the heating operation.)
operation display lamp are controlled as shown in Fig. 7-3-8.
° C
0
0.5
(Room temp.) (Preset temp.)
ON
OFF
ON
Compressor
ON
OFF
ON
4-way valve
Outdoor fan
OPERATION
display lamp
(2) The microprocessor turns the compressor on and
off at the regular intervals (4 to 6 minutes). While the compressor is turning off, the indoor fan motor operates in the SUPER LOW position. The pattern of operation depending on the relation between room temperature and preset temperatures is shown in Fig. 7-3-7.
Room temp.
Preset temp.+1
Preset temp.
Compressor
Outdoor fan
Indoor fan
ON ON ON ON
OFF OFF OFF
L. *S.L. S.L.L. L. S.L. L.
*Super Low
Fig. 7-3-7
(3) [FAN] button on the remote control is set to AUTO
only.
Fig. 7-3-8
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-3-9. When [FAN] button is set to LOW, LOW+, MED, MED+ or HIGH, the motor operates with a constant air flow.
Preset temp.
°C
0
-0.5
-1
-1.5
-2
-5.0
-5.5
[FAN AUTO]
(Room temp.) (Preset temp.)
L
*1 *2
+
M
H
*1 : Fan speed = (M + L) x 1/4 + L
*2 : Fan speed = (M + − L) x 2/4 + L *3 : Fan speed = (M + L) x 3/4 + L
(Calculated with inear approximation from M+ and L+)
(4) The ECO and Hi Power operations can not be set.
Fig. 7-3-9
19
y.
c
e
U
.
c
U
g
y
(3) The indoor heat exchanger restricts revolving
speed of the fan motor to prevent a cold draft. The upper limit of the revolving speed is shown in Fig. 7-3-10 and Table 7-3-2.
T
46
34
45 33
33 21 32 20
*A+4 *A+4 *A-4 *A-4
Fan speed MAN Fan speed AUTO in stabilit
* No limitation while fan speed MANUAL mode is in stabilit * A: When Tsc 24, A is 24, and when Tsc < 24, A is Ts
Tsc: Set valu
H
Line-approximate H and S
SUL
L with Tc
Stop
AL in startin
Fig. 7-3-10 Cold draft preventing control
Table 7-3-2
Fan *5 *6 speed Starting period Stabilized period
AUTO • Up until 12 minutes
passed after starting the unit
From 12 to 25 minutes passed after starting the unit and room temperature is 3°C lower than preset temperature
Manual • Room temperature (L – H) < Preset temperature
From 12 to 25 minutes passed after starting the unit and room temperature is between preset temperature and 3°C lower than preset temperature
25 minutes or more passed after starting the unit
Room temperature
Preset temperature
4°C
3.5°C
7-3-5. Automatic operation
([MODE] button on the remote control is set to the automatic operation.)
(1) One of 3 operations (Cooling, Fan only or Heating)
is selected according to difference between the preset temperature and the room temperature at which the automatic operation has started, as shown in Fig. 7-3-11. The Fan only operation continues until the room temperature reaches a level at which another mode is selected.
(2) Temporary Auto
When the RESET button on the indoor unit is pushed, the preset temperature is fixed at 24°C and the indoor unit is controlled as shown in Fig. 7-3-11.
RAS-10SKHP-ES
°C
Cooling operation
0
Fan only operation
-1
Heating operation
(Room temp.) (Preset temp.)
RAS-10SKP-ES
°C
Cooling operation
0
Heating operation
(Room temp.) (Preset temp.)
Fig. 7-3-11
20
7-4. High-Temperature Limit Control
The microcontroller detects the indoor heat exchanger temperature to prevent pressure of a refrigerating cycle from increasing excessively. The compressor and outdoor fan motor are controlled as shown in Fig. 7-4-1.
Compressor
OFF
ON
ON
Outdoor fan
OFF
OFF
ON
Heat exchanger temp.
(°C) 60
53 52
Fig. 7-4-1
7-5. Low-Temperature Limit Control
The microcontroller detects the indoor heat exchanger temperature to prevent the indoor heat exchanger from freezing. The compressor and outdoor fan motor are controlled as shown in Fig. 7-5-1 and 7-5-2.
7-6. Defrost Operation
*Heat pump model only*Heat pump model only
During the heating operation, the outdoor heat exchanger temperature goes down and sometimes it is frozen. In this case, the air conditioner stops the heating operation and starts the defrost operation to melt ice.
7-6-1. Condition to start the defrost operation
The defrost operation starts whichever below conditions are satisfied.
(1) When the cumulative compressor operating time is
longer than 40 or 90 minutes and difference between the indoor heat exchanger temperature and the room temperature is less than the specified value. (This value is decided by the microprocessor.) (Control example is shown in Fig. 7-6-1. In case of B or C, the defrost operation starts.)
(2) When the current limit control or the high
temperature limit control is performed for total of 90 minutes.
RAS-10SKHP-ES RAS-10SKP-ES
Heat exchanger temperature
(°C)
5
2
Compressor Outdoor fan
Fig. 7-5-1
ON
Less than 2°C continues
for 5 minutes
OFF
D
xchanger temp
A
Indoor heat e
- Room temp
Fig. 7-6-1 (Indoor fan speed : M)
7-6-2. Defrost operation time control
<In case of B>
(1) The heating operation is performed for at least
40 minutes.
(2) The maximum defrost operating time is 6 minutes.
The defrost operating time for the 4th cycle is 10 minutes. (When the outdoor temperature is very low, however, the defrost operating time is 10 minutes.)
B
C
Cumulative compressor operating time
21