Toshiba EX250 User Manual

r 1

In Touch with Tomorrow

EX250/500

PROGRAMMABLE CONTROLLERS
Start BCD to Binary CONVRT
03
2
^04 ^0^
Remote Thumb­input wheel switch input PERMIT ThMWHL
[XW01
li '
BIN
Binary S'* thmwhl t
data
8INDAT
0100^
C^гcu^t Line Device Move
16Coniment 7Comfnen 18Corm)efTt9Cofnrner
Min

ilgi xloi

Mult
pi 1i date
PRODI.
D10{
.. i -I
• High Speed Scanning
• On Line Programming
T

Enhanced Features

I .
( I
• On Line Program Saving
• Optional Clock-Calendar
I

FEATURES

Fast Scan

The EX250/500 uses a 16 bit microprocessor and custom Toshiba integrated circuits to significantly reduce program scan time.

TWO CPU TYPES

The only difference between the EX250 and the EX500 is the CPU card
EX500
8K steps
512 points
• Application Memory
• Execution Speed
• Max Local I/O
EX250
4K steps
1.1 fis/contact 65 ^s/16 bit addition 256 points
0,75 fi.s/contact 65 fis/16 bit addition

Advanced Instruction Set

There are 15 basic relay ladder instructions and 64 special function block instructions. The function blocks include instructions for performing:
• Arithmetic Operations • Data Manipulation • Trig. Functions
• Register Logic • Comparisons • Upper/Lower Limit
• Min/Max/Avg, • Step Sequencer • Shift Register
• Function Generator; Given x, solve for f(x) where f(x) is interpolated based on a pre-entered set of x, y points.

Flexible Networking

EX250/500's are easily linked to:
• Higher Level Computers
Remote I/O Stations
• Other EX250/500’s

Easy Program Modification

Testing and modifying logic programs is simple. All controllers have:
• Real time power follow monitor • Forced I/O
• Instruction Search • Data Set
• On-line (in Run mode) program edit

Intelligent I/O Modules

Several intelligent, specialized I/O modules are available:
• ASCIl/Basic Module • 4 Channel PID Control Module
• High Speed/Quadrature Input Module • Motion/Stepper Control Module

Clock Calendar

The clock calendar function allows data gathering based on time, time scheduled operations, etc. Time is kept by:
• Second • Minute • Hour
• Day • Month • Year
The compact modular structure of the EX250/500 is designed for easy installation. Diagnostic LEDs are immediately visible, and components can be readily removed and replaced.
CONTROLLER UNIT
The only difference between the EX250 controller and the EX500 controller is the CPU card. The controller unit consists of:
• CPU which contains 1, CPU Card.
2, Power Supply Card. 3, Space for Optional Computer Interface Card
• Backplane which contains space for 8 I/O Modules
DIAGNOSTIC LEDs (RUN, CPU, I/O, PROG, POWER. ВАТТ, COMM, HOLD)
RUN/HALT selector switch
EXPANSION UNIT
The expansion unit consists of a backplane and space for additional I/O modules.
Cable connector to controller unit

I/o EXPANSION CAPABILITY

EX250

One (1) expansion unit can be connected to each EX250 controller. A total of 16 I/O slots are available. If 32 point I/O modules are used, all the discrete I/O can be located on the controller leaving the expansion unit available for register type I/O (Analog, PID, BCD, etc.)
Local I/O
• 2S6 points or
• 32 registers

EX500

Three (3) expansion units can be connected to each EX500 controller. A total of 32 I/O slots are available. If 32 point I/O modules are used, all the discrete I/O can be located on the controller and the first expansion unit leaving the last two expansion units available for register type I/O (Analog, PID, BCD, etc.).
Local I/O
• 512 points or
• 64 registers
Notes: 1) A 0.5 m expansion cable is shipped with each expansion unit. Optional I m expansion cables are
also available. Total cable length should be less than 2 m.
2) Four types of expansion units are available
EU-6237 480 mm width, 8 ilou, with AC power »upply EU*6257D 480 mm width, 8 slots, with DC power supply EU-6279 390 mm width, 8 slots, no power supply EU-6278 240 mm width, 4 slots, no power supply, tentiiiution only
If total 5 Vdc current consumption will exceed 4.5 A, the expansion unit with power supply
must be used.

NETWORKING

TOSLINE-30/30OP
TOSLINE-30 is an N-to-N data link system dedicated to the EX-series of programmable controllers. The TOSLINE-30 data communication modules allow EX250/500’s to be set-up in a peer-to-peer configuration, master-to-slave configuration, or to use remote I/O.
Wire System (TOSLINE-30)
^11
1
Master (MSE)
Controller Station (wire) (MSE.5626)
TOSLINE-30
r
---------
EX ■
1
Remote (MSE)
tSB
Remote I/O (RSE)
Remote I/O Station (wire) (RSE-5618)
Topology Party line (multi-drop) Transmission speed Transmission distance No. of stations 17 maximum Transmission capacity Response speed Cliecking method Cable
187.5K bps 1 km maximum (total)
8/16/32 registers (cyclic) 25 ms/32 registers Inverted double transmission
Shielded twisted pair
Remote (OPMS)
Remote (OPMS)
Remote I/O (OPRS)
-14^!
r.n 1.
J ' 1 ! i
^ : ■ j ’ ■ ■ j
r] r
' 1 ! i
, ... 4.
^
1 ^
j
1
-----------
1
; ! 1
J . • -
„1 . .
: j
1
- I I I
! 1.
1 1 1
The optional computer link card allows up to 8 EX250/500’s to be networked on one RS422 serial link back to a personal computer, cell controller, or other higher level computer. The computer can run Toshiba’s EXPDD programming software, various graphics display and data acquisition software, or user designed custom software.
Compuler Link Module (CM P-6336)
EX250/SOO
Loading...
+ 14 hidden pages