Toshiba B-EP800-AC-QM-R Owner's Manual

TOSHIBA AC Adapter
B-EP800-AC-QM-R
Owner's Manual
Before using the unit, please read this manual thoroughly and retain it for future reference.
This symbol is intended to alert the user to the presence of uninsulated “Dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
NOTE: No user-serviceable parts inside. Refer servicing to qualified service personnel.
Copyright © 2008 by TOSHIBA TEC CORPORATION All Rights Reserved 570 Ohito, Izunokuni-shi, Shizuoka-ken, JAPAN
< For EU Only > TOSHIBA TEC Europe Retail Information Systems S.A. Rue de la Célidée 33 BE-1080 Brussels
E
PRINTED IN JAPAN EO1-33082 7FM03290000
<English>
<Franaçis>
<Deutsch>
<Español>
<Nederlands>
<Italiano>
<Português>
<Polski>
<한국어>
<中文(繁體字)>
CAUTION!
Do not use this device for any devices other than the B-EP2DL or B-EP4DL series portable printer.
PRÉCAUTIONS!
N’utilisez pas ce dispositif pour une machine autre que les imprimantes portables de la gamme B-EP2DL ou B-EP4DL.
Achtung!
Benutzen Sie dieses Netzteil für kein anderes Modell außer dem B-EP2DL oder dem B-EP4DL.
ATENCIÓN!
No utilice este adaptador para ningún otro dispositivo distinto a las impresoras portátiles B-EP2DL o B-EP4DL.
WAARSCHUWING!
Gebruik dit toebehoren uitsluitend met draagbare printers van de reeksen B-EP2DL of B-EP4DL.
ATTENZIONE!
Non utilizzare questo adattatore se non per la serie di stampanti portatili B-EP2DL o B-EP4DL .
UWAGA!
Nie należy używać tego urządzenia z urządzeniami innymi niż przenośne drukarki serii B-EP2DL lub B-EP4DL.
주의
!
포터블 프린터 B-EP2DL / B-EP4DL 시리즈 이외에는 사용 하지 말아 주십시오.
注意! 本機只適用与携帯型列印機B-EP2DL / B-EP4DL系列。
ATENÇÃO!
Não utilize este dispositivo para quaisquer outros dispositivos que não a série de impressoras portáteis B-EP2DL ou B-EP4DL. .
CAUTION! (For customers in U.S.A. and Canada)
1.To prevent electric shock, match wide blade of plug to wide slot, fully insert.
2.To reduce the risk of hazards, use only CSA/UL Certified power cord set. Cord is TypeSPT-2 or heavier, minimum NO.18 AWG copper, one end is provided with a moulded-on male attachment plug cap (with a specified NEMA configuration), and the other end is provided with a moulded-on female connector body (with a specified IEC non-industrial type configuration).
CE Compliance (for EU only)
This product complies with the requirements of EMC and Low Voltage Directives including their amendments.
NOTES:
1.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
2.Changes or modification not expressly approved by manufacturer for compliance could void the user’s authority to operate the equipment.
“This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. ” “Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur lematériel brouilleur du Canada.” (for CANADA only)
4
NOTICE FOR THE CUSTOMERS IN THE UNITED KINGDOM A moulded plug complying with BS 1363 is fitted to this equipment for your safety and convenience.
Should the fuse in the plug supplied need to be replaced, a 5 AMP fuse
approved by ASTA or BSI to BS 1362, (i.e., marked with
or mark) must
be used.
If the plug supplied with this equipment has a detachable fuse cover, be sure to attach the fuse cover after you change the fuse. Never use the plug without the fuse cover. If you should lose the fuse cover, please contact your nearest TOSHIBA TEC service representative.
Others
• The model name plate indicating the operating voltage, power consumption, etc. is located on the bottom of the unit.
• Unplug the unit from the wall outlet if it will not be used for an extended period of time. To disconnect the cord (mains lead), pull it out by the plug. Never pull the cord itself.
• Do not operate the unit with a damaged cord or if it has been dropped or damaged.
• Be sure that nothing metallic comes into contact with the metal parts of the unit or connecting plate. If it does, a short may occur and the unit may be damaged.
• Always keep the metal contacts clean.
• Do not disassemble or convert the unit.
• Do not apply mechanical shock or drop the unit.
• The unit may become warm whilst in use, this is perfectly normal.
• Keep the unit away from AM receivers, because it will disturb AM reception.
• Do not place the unit in a location where it is:
• Temperatures out of the specification
• Dusty or dirty
• Very humid
• Vibrating If any difficulty should arise, unplug the unit and contact your Authorised TOSHIBA TEC representative.
1. To prevent fire or shock hazard, do not expose the unit to rain or moisture.
2. To avoid electrical shock, do not open the cover.
3. Refer servicing to qualified personnel only.
4. For indoor use only.
5
Before using this unit:
Please follow the instructions below to use the B-EP800-AC-QM-R correctly.
• The B-EP800-AC-QM-R is an AC adapter designed for charging the battery pack loaded in the B-EP2DL/B-EP4DL series portable printers, not for directly supplying the power to the B-EP2DL/B-EP4DL series portable printers.
This product and the AC adapter supplied with the B-EP800-CHG-QM-R Battery
Charger are the same product.
• DO NOT connect this AC adapter to any devices other than the B-EP2DL/B­EP4DL series portable printer. We assume no responsibility for any results arising from a connection to other devices.
• Before connecting this AC adapter to the printer, please make sure that the battery pack is in the printer. We are not responsible for any results due to a failure to do so.
Connecting the AC Adapter to the Printer
When charging the battery pack loaded in the B-EP2DL/B-EP4DL series portable printer, use the following procedure to connect the AC adapter to the printer. For how to check the charge status, please refer to the Owner’s Manual of the B­EP2DL/B-EP4DL series portable printer.
1. Make sure that the battery pack is in the printer.
2. Connect the AC adapter to the DCIN connector of the printer.
3. Connect the power cord to an AC outlet.
4. When the AC adapter is plugged in, the external power source symbol (
) is
displayed on the printer’s LCD, and charging starts. Whether the battery charge is required or not is automatically determined by the printer.
5. When the charging is completed, unplug the power cord from the AC outlet and
disconnect the AC adapter from the printer.
NOTE:
Charging time may differ depending on the condition of the battery pack or the operating temperature.
AC Adapter
Portable Printer
Plug
DCIN Connector
Power Cord
Power Plug
AC outlet
6
Troubleshooting
If you have any problems while using this product, please check the following point first. If a problem cannot be solved by taking actions described below, unplug the AC adapter and contact the dealer or an authorized TOSHIBA TEC service representative for assistance.
Symptom Cause and resolution
The power is not supplied even if the power cord is connected to an AC outlet.
(
is not displayed.)
The AC adapter is not connected to the printer completely. Firmly connect the AC adapter to the printer.
The power cord is not connected to the AC adapter completely. Firmly connect the power cord to the AC
adapter.
The power cord is not connected to the AC outlet completely. Firmly connect the power cord to the AC outlet.
A power failure Please wait until the power is recovered.
Power is not supplied to the AC outlet.
Test with other electric appliances. If the power is not
supplied to the AC outlet, please consult the nearest power company.
The fuse or breaker of the building has blown out. Check the fuse and the breaker.
The printer is not in stand-by.
The external power source symbol is not displayed while the
printer is not in the stand-by state.
The CHARGE lamp does not light up. The battery pack is not loaded in the printer.
Load a battery pack in the printer.
The battery pack loaded in the printer has been fully charged. A fully charged battery pack is not charged, so
the CHARGE lamp does not light up.
The ambient temperature or the battery pack temperature does
not fall within the operable temperature range.
Charge the battery pack within 0ºC to 40ºC. A
battery charge may not be started outside this range.
Specifications
Type: B-EP800-AC-QM-R (Model: 0225A1950) Input voltage: 100 to 240V AC, 50/60 Hz Output voltage: DC19V, 2.63A Application: TOSHIBA Portable Printer B-EP2DL/ B-EP4DL Series Operating temperature: 0°C to 40°C (32°F to 104°F) Operating humidity: 20 to 80% (No condensation) Storage temperature: -20°C to 70°C (-4°F to 158°F) Storage humidity: 10 to 90% (No condensation) Dimensions: 98 x 42 x 29.2mm (L/W/H)
(3.86 x 1.65 x 1.15 inches) (Excluding the projecting parts) Weight: 250g (8.8 oz) Accessories: Owner’s Manual x 1
NOTE: Design and specifications are subject to change without notice.
7
When purchasing the power cord:
Since the power cord set is not enclosed in this unit, please purchase an approved one that meets the following standard from your authorized TOSHIBA TEC representative.
(As of August 2008)
Country Agency
Certification
mark
Country Agency Certification mark Country Agency Certification mark
Australia SAA Germany VDE
Sweden SEMKKO
Austria OVE
Ireland NSAI
Switzerland SEV
Belgium CEBEC
Italy IMQ
UK ASTA
Canada CSA
Japan METI
UK BSI
Denmark DEMKO
Netherlands KEMA
U.S.A. UL
Finland FEI
Norway NEMKO
Europe HAR
France UTE
Spain AEE
China CCC
Power Cord Instruction
1. For use with 100 – 125 Vac mains power supply, please select a power cord rated Min. 125V, 10A.
2. For use with 200 – 240 Vac mains power supply, please select a power cord rated Min. 250V.
3. Please select a power cord with the length of 2m or less.
4. The power cord plug connected to the AC adapter must be able to be inserted to an ICE-320-C6 inlet. Refer to the following figure for the shape.
Country/Region North America Europe
United
Kingdom
Australia China
Power Cord
Rated (Min.) Type
Conductor size (Min.)
125V, 10A SVT
No. 3/18AWG
250V H05VV-F
3 x 0.75 mm
2
250V H05VV-F
3 x 0.75 mm
2
250V AS3191 approved,
Light or Ordinary Duty type
3 x 0.75 mm2
250V GB5023
3 x 0.75 mm
2
Plug Configuration (locally approved type)
Rated (Min.)
125V, 10A
250V, 10A
250V, *1
250V, *1
250V, *1
*1: At least, 125% of the rated current of the product.
Loading...