TOREX XBS104S13R-G User Manual

A
x
XBS104S13R-G
Schottky Barrier Diode, 1A, 40V Type
FEATURES
Forward Voltage Forward Current Repetitive Peak Reverse Voltage : V Environmentally Friendly : EU RoHS Compliant, Pb Free
Ta=25
BSOLUTE MAXIMUM RATINGS
Repetitive Peak Reverse Voltage VRM 40 V Reverse Voltage (DC) VR 40 V Forward Current (Average) IF(AV) 1 A Non Continuous Forward Surge Current Junction Temperature Tj 125 Storage Temperature Range T stg
*1Non continuous high amplitude 60Hz half-sine wave.
MARKING RULE
PARAMETER SYMBOL RATINGS UNIT
: VF=0.49V (TYP.) : I
F(AV)
RM
*1
=1A
=40V
I
FSM 10 A
-55+150
ETR1608-003
APPLICATIONS
Rectification
Protection against reverse connection of battery
PACKAGING INFORMATION
Cathode Bar
: 1 (Product Number)
PRODUCT NAME
PRODUCT NAME DEVICE ORIENTATION
XBS104S13R-G SOD-323A (Halogen & Antimony free)
XBS104S13R SOD-323A
* The “-G” suffix indicates that the products are Halogen and Antimony free as well as being fully RoHS compliant. * The device orientation is fixed in its embossed tape pocket.
ELECTRICAL CHARACTERISTICS
Ta=25
*2trr measurement circuit
PARAMETER SYMBOL TEST CONDITIONS
Forward Voltage
Reverse Current IR VR=40V - 4 200 Inter-Terminal Capacity Ct VR=10V , f=1MHz - 35 - pF
Reverse Recovery Time *2 trr
Pulse Generatri
: Assembly Lot Number
Unit : mm
SOD-323A
LIMITS
MIN. TYP. MAX.
VF1 IF=100mA - 0.34 - V V
F2 I
=1A - 0.49 0.54 V
F
I
=10mA , irr=1mA , RL=100Ω
F=IR
Bias
バイアス
Device Under Test
A
被測定イオード
Oscilloscope
オシロスコーパルス発生器
I
F
0
irr
- 25 - ns
trr
t
UNIT
μA
I
R
1/3
A
XBS104S13R-G
TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage (2) Reverse Current vs. Reverse Voltage
1
10000
Ta=125℃
1000
Forward Current: IF (A)
(A)
F
0.1
Ta=125℃
0.01
25℃75℃
-20℃
Forward Current I
0.001 0 0.2 0 .4 0.6
Forward Voltage: VF (V) Reverse Voltage: VR (V)
Forward Voltage V
F
(V)
Reverse Current: IR (μA) Reverse Current: IR (μA)
(uA)
R
100
75℃
10
25℃
Reverse Current I
1
0.1 0 10203040
Reverse Voltage V
R
(V)
(3) Forward Voltage vs. Operating Temperature (4) Reverse Current vs. Operating Temperature
0.6
(V)
F
0.4
IF=1A
10000
1000
(uA)
R
VR=40V 20V
100
0.5A
5V
0.2
Forward Voltage V
Forward Voltage: VF (V)
0.0
-50 0 50 100 150
Operating Temperature: Ta () Operating Temperature: Ta ()
Operating Temperature Ta ()
0.1A
0.01
Reverse Current I
1
0.1 0 50 100 150
Operating Temperature Ta ()
(5) Inter-Terminal Capacity vs. Reverse Voltage (6) Average Forward Current vs. Operating Temperature
10
200
150
100
50
Inter-Terminal Capacity Ct (pF)
Inter-Terminal Capacity: Ct (pF)
Ta=25℃
0
0 10203040
2.0
(A)
AV
1.5
1.0
0.5
Average Forward Current IF
Average Forward Current: IFAV (A)
0.0 0 50 100 150
Operating Temperature Ta ()
Reverse Voltage V
R
(V)
Operating Temperature: Ta () Reverse Voltage: VR (V)
2/3
Loading...
+ 1 hidden pages