Schottky Barrier Diode, 100mA, 30V Type
FEATURES
Forward Voltage Forward Current Repetitive Peak Reverse Voltage Environmentally Friendly
Ta=25
BSOLUTE MAXIMUM RATINGS
Repetitive Peak Voltage VRM 30 V Reverse Voltage(DC) VR 30 V Forward Current(Average) IF(AV) 100 mA Non Continuous Forward Surge Current Junction Temperature Tj 125 Storage Temperature Range Tstg
*1Non continuous high amplitude 60Hz half-sine wave.
MARKING RULE
PARAMETER SYMBOL RATINGS UNIT
*1
: VF=0.71V (TYP.)
=100mA
: I
F(AV)
=30V
: V
RM
: EU RoHS Compliant, Pb Free
FSM 0.6 A
I
-55+150
ETR1604-003
APPLICATIONS
Low Current Rectification
PACKAGING INFORMATION
Cathode Bar
: 0 (Product Number) : Assembl
PRODUCT NAME
PRODUCT NAME DESCRIPTION
XBS013S16R SOD-723
XBS013S16R-G SOD-523 (Halogen & Antimony free)
* The “-G” suffix indicates that the products are Halogen and Antimony free as well as being fully RoHS compliant. * The device orientation is fixed in its embossed tape pocket.
ELECTRICAL CHARACTERISTICS
PARAMETER SYMBOL TEST CONDITIONS
Forward Voltage
Reverse Current IR VR=25V - - 2 Inter-Terminal Capacity Ct VR=0V , f=1MHz - 6 - pF Reverse Recovery Time*2 trr IF=IR=10mA , irr=1mA - 2 - ns
*2trr measurement circuit
Pulse Generatrix
Bias
VF1 IF=1mA - 0.31 - V V
Lot Numbe
F2
I
F
Device Under Test
=100A
SOD-723
MIN. TYP. MAX.
- 0.71 1 V
Oscilloscope
Unit : mm
Ta=25
UNIT
μA
1/3
XBS013S16R-G
TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage (2) Reverse Current vs. Reverse Voltage
100
(mA)
F
10
Ta=125℃
-25℃
25℃75℃
1000
(uA)
R
100
10
Ta=125℃
75℃
1
1
R
25℃
(V)
Forward Current : IF (mA)
Forward Current I
0.1 0 0.2 0.4 0.6 0.8
Forward Voltage : VF (V)
Forward Voltage V
F
(V)
Reverse Current : IR (uA)
Reverse Current I
0.1
0.01 0102030
Reverse Voltage : VR (V)
Reverse Voltage V
(3) Forward Voltage vs. Operating Temperature (4) Reverse Current vs. Operating Temperature
0.8
IF=100mA
0.6
(V)
F
(uA)
R
1000
100
10
0.4
10mA
1
VR=25V
15V
5V
0.2
Forward Voltage V
Forward Voltage : VF (V)
0.0
-50 0 50 100 150
Operating Temperature : Ta ()
Operating Temperature Ta ()
1mA
Reverse Current I
Reverse Current : IR (uA)
0.1
0.01 0 50 100 150
Operating Temperature : Ta ()
Operating Temperature Ta ()
(5) Inter-Terminal Capacity vs. Reverse Voltage (6) Average Forward Current vs. Operating Temperature
Average Forward Current : IFAV (mA)
250
(mA)
200
AV
150
100
50
Average Forward Current IF
0
0 50 100 150
50
40
30
20
10
Inter-Terminal Capacity Ct (pF)
Inter-Terminal Capacity : Ct (pF)
Ta=25℃
0
0102030
2/3
Reverse Voltage : VR (V)
Rever se Volt age V
R
(V)
Operating Temperature Ta ()
Operating Temperature : Ta ()
Loading...
+ 1 hidden pages