This product is in compliance with the essential requirements and other relevant
provisions of the directive 89/336/EEC.
The Declaration of conformity can be found on:
http://www.topcom.net/support.cedeclarations.php
GB The features described in this manual are published with reservation to modifications.
DE Die in dieser Bedienungsanleitung umschriebenen Möglichkeiten, werden vorbehaltlich
Änderungen publiziert.
SFunktionerna i denna bruksanvisning publiceras med reservation för ändringar.
DK Vi forbeholder os retten til ændringer af de specifikationer, der er beskrevet
i denne brugsanvisning.
ES Las características descritas en este manual pueden ser objeto de futuras modificaciones.
TOPCOM HBM Sensor Watch 20023
1INTRODUCTION
Congratulations on your purchase of the HBM Sensor Watch 2002. We hope that you will enjoy
using the Heart Meter and the benefits it offers. In exercise or sports, your heart naturally speeds
up in pumping blood to the body in accordance with the increased energy level. With the Heart
Meter you can measure this increase expressed as the number of beats per minute (bpm). The
HBM Sensor watch supports 5 User modes:
ENGLISH
1.Normal Time Mode
2.Alarm Time Mode
3.Heart Meter Mode
4.Chronograph Mode
5.Countdown Timer Mode
2SAFETY NOTES
Read carefully through the following information concerning safety and
proper use. Make yourself familiar with all functions of the device. Keep
this manual on a safe place for future use.
Using a Heart Monitor is NOT a substitute for professional medical attention. If you suffer from
heart disorder, illness or have recently taken up fitness training, it is advisable that you seek a
doctor or talk to your trainer and work out a fitness plan that suits you.
The HBM SW 2002 should only be used as a guide in maintaining a safe heart beat rate. It should
NOT be relied upon as a medical heart rate monitor. If you are uncertain about how your exercise
program will impact on your heart, please consult a physician.
4TOPCOM HBM Sensor Watch 2002
3CARE AND MAINTENANCE
Never use force to open the case or remove back coverl DO NOT expose the watch to extreme
weather conditions or cleaning agents and solvents. Avoid dropping or rough handling of the
watch. Clean the watch with a dry soft cloth or a soft cloth moistened with water and mild
detergent. Store the watch in a dry place when not in use.
4DISPOSAL OF THE DEVICE (ENVIRONMENT)
At the end of the product lifecycle, you should not throw this product into the
normal household garbage but bring the product to a collection point for the
recycling of electrical and electronic equipments. The symbol on the product,
user guide and/or box indicate this.
Some of the product materials can be re-used if you bring them to a recycling point. By re-using
some parts or raw materials from used products you make an important contribution to the
protection of the environment. Please contact your local authorities in case you need more
information on the collection points in your area.
TOPCOM HBM Sensor Watch 20025
5BUTTONS
6
1.START/STOP - button (ST./STP.)
5
2.RESET - button
4
1
3.MODE- button
4.LIGHT - button
ENGLISH
3
5.1 MASTER RESET
Press and hold ST./STP., RESET en MODE simultaneously to reset the HBM SW 2002.
!!! All set information will be lost, also the date and time.
5.2 BACK LIGHT
Press LIGHT briefly to active the back light of the display.
2
5.LCD display
6.Sensor
6TOPCOM HBM Sensor Watch 2002
6FUNCTIONAL MODES
The HBM Wrist includes 5 functional modes
4
3
Normal Time Mode will be displayed when NO key is pressed within 1 minute.
5
2b
1
2a
7TIME AND DATE
In time Current Time mode :
• Press ST./STP. to select the date
• Press ST./STP. to switch back to time. If no button is
pressed within 8 seconds, it will switch automatically back
to time mode.
Press MODE to scroll through the next
functional modes.
1.Currect Time
2.Heart rate alarm mode
a. Heart rate alarm ON
b. Heart rate alarm OFF
3.Daily alarm mode
4.Cronograph mode
5.Timer mode
TOPCOM HBM Sensor Watch 20027
7.1 SETTING TIME AND DATE
In time Current Time mode :
• Press and hold MODE until the seconds are blinking on the display.
• Press ST./STP. to set the seconds to zero.
• Press MODE to switch to minutes.
• Press ST./STP. to increase the minutes or RESET to decrease the minutes.
• Press MODE to switch to hours
• Follow the same instruction as for the minutes to adjust the hour, year, month and day.
After setting the date
• Press ST./STP. to select the visualisation of the date (‘month/day’ or ‘day/month’).
• Press MODE to switch hour setting.
• Press ST./STP. to select 24Hours system or 12Hours systems (indication AM/PM)
• Press MODE to switch to the keybeep setting.
• Press ST./STP. to set the keybeep on (ON) or off (OF)
• If the date and time is correct, press and hold MODE to fix the setting.
ENGLISH
8TOPCOM HBM Sensor Watch 2002
8DAILY ALARM
8.1 SETTING THE DAILY ALARM
- Press MODE 2 times to go to Alarm Mode
- Press and hold MODE until the hour is blinking on the display.
- Press ST./STP. to increase the hour or RESET to decrease the hour.
Once you change the hour, the alarm will be On and the daily alarm icon
is displayed.
- Press MODE to switch to minutes.
- Press ST./STP. to increase the minutes or RESET to decrease the min-
utes.
- If the time is correct, press and hold MODE to fix the setting.
8.2 ACTIVATING/DEACTIVATING ALARM
- Press MODE 2 times to go to Alarm Mode
- Press ST./STP. to activate/deactivate the daily alarm. When the Daily
Alarm is ON, is displayed.
- Press RESET to activate/deactivate the Hourly chime. When the Hourly
Chime is ON, is displayed. The watch will now beep every hour.
TOPCOM HBM Sensor Watch 20029
9CHRONOGRAPH MODE
The maximum counting time is 99 hours, 59 minutes and 59,99 seconds.
- Press MODE 3 times to go to Chronograph Mode
- When 0:00 displayed, press ST./STP. to start counting.
- Press ST./STP. again to stop counting.
- Press RESET to reset the counter to 0:00
10TIMER MODE
The maximum count down time is 99 hours, 59 minutes and 59 seconds.
To set the countdown time.
- Press MODE 4 times to go to Timer Mode.
- Press and hold MODE until the hour is blinking on the display.
- Press ST./STP. to increase the hour or RESET to decrease the hour.
- Press MODE to switch to minutes.
- Follow the same instruction as for the hour to adjust the minutes and
seconds.
- If the time is correct, press and hold MODE to fix the setting.
ENGLISH
- Press ST./STP. to start counting down.
- Press ST./STP. again to stop counting.
- Press RESET to reset the counter to set time.
10TOPCOM HBM Sensor Watch 2002
11HEARTBEAT MEASUREMENT
11.1 IMPORTANT NOTES
1.A sensor contact located on the back of the watch must make firm contact with the user's
skin during measurement.
2.DO NOT take measurement when diving or under water.
3.Clean the back cover occasionally by applying a few drops of water and then wipe it with a
paper towel thoroughly to remove any residual grease.
4.DO NOT use hand cream, it will insulate the signal between the skin and the sensors. Rub
the skin and the fingers with soap and water occasionally for better signal transmission.
5.DO NOT use the finger tips where the skin is dry and thick. For those with extremely dry
skin, moisten fingers and wrist with tap water.
6.Hold the watch firmly while taking a measurement in motion, this assists the sensors in
making firm contact with the skin and fingers.
7.During the measurement, avoid any abrupt motion. It will create undesired noise, hence
an error heart beat reading may result.
8.Before you use the heart rate alert function (see §11.3), get your heart rate limits from your
doctor or personal trainer. Even if you let the watch define your limits by gender and age,
compare the limits with the one you received from your doctor or personal trainer.
TOPCOM HBM Sensor Watch 200211
11.2 MEASUREMENT
With this watch you can measure your current heart rate expressed in beats per minute (bpm)
The heart rate can be measured during any functional mode, but cannot
be measured when setting date,time and alarm.
In any functional mode
- Press the lower sensor with your index finger while placing
your middle finger on the upper sensor.
- A beep confirms that measurement has started and the display will flash.
- Hold that position for about 6 seconds until you hear a second beep. Your heart rate appears on the display.
- Remove the fingers from the sensor.
- The heart rate will remain on the display for 5 seconds before
it return to the previous mode.
ENGLISH
12TOPCOM HBM Sensor Watch 2002
11.3 HEART RATE ALERT FUNCTION.
The heart rate range can be set for people who want to keep their heart rate within their objective
training limits or for people who need to keep their heart rate within 2 limits for health reasons.
11.3.1 Measurement with alert function on.
Depending on the age and gender, the Maximum Heart Rate (MHR) is calculated as follow:
• MHR Female = 226 - user age
• MHR Male = 220 - user age
Before measurement make sure the heart rate limits
are set and the heart rate alert function is on.
85% x MHR
65% x MHR
(§11.3.2/3)
When you do a measurement with the Heart Rate
Alert function on, the watch will indicate the Relative
Heart Rate (HRR). This is the measured heart rate as
percentage of the Maximum Heart Rate.
If the heart rate is out of the range, you will hear a
double beep tone and the heart rate is flashing on the
display.
HRR
If you use the automatically defined Upper and Lower
limit, the watch will indicate the Relative Heart Rate
also in a Graphical Bar when this is within the limits
from 65% to 85% of the Maximum Heart Rate.
TOPCOM HBM Sensor Watch 200213
11.3.2 Setting the upper and lower limit based on gender and age.
3SEC
3SEC
In Normal Time mode
• Press MODE once to go to Heart Rate Alert mode
• Press and hold MODE until the age is blinking on the display.
• Press ST./STP. to increase the age or RESET to decrease the age.
• Press MODE to switch to gender.
• Press ST./STP. to change the gender to female (f) or male (m).
After setting the gender and age, the watch will automatically define a training range with an
upper and lower level as follow.
- Higher Limit (H) = MHR x 85%
- Lower Limit (L) = MHR x 65%
• Press and hold MODE to leave the setting, the higher and the lower limit will show
sequentialy.
ENGLISH
14TOPCOM HBM Sensor Watch 2002
11.3.3 Setting the upper and lower limit manually.
• Press MODE once to go to Heart Rate Alert mode
• Press and hold MODE until the age is blinking on the display.
3SEC
• Press MODE twice to select the Higher level (H).
• Press ST./STP. to increase or RESET to decrease the level.
• Press MODE to switch to select the Lower level (L).
• Press ST./STP. to increase or RESET to decrease the level.
• Press and hold MODE to leave the setting.
When the Higher and Lower level is set manually, the graphical bar will
not be displayed during measurement.
11.3.4 Activating/deactivating the heart rate alert function.
In Normal Time mode
• Press MODE once to go to Heart Rate Alert mode
• Press ST.STP. to enable (On) or disable (Of) the heart rate alert function.
TOPCOM HBM Sensor Watch 200215
12TOPCOM WARRANTY
12.1 WARRANTY PERIOD
The Topcom units have a 36-month warranty period. The warranty period starts on the day the
new unit is purchased. Consumables or defects causing a negligible effect on operation or value
of the equipment are not covered.
The warranty has to be proven by presentation of the original purchase receipt, on which the date
of purchase and the unit-model are indicated.
12.2 WARRANTY HANDLING
A faulty unit needs to be returned to a Topcom service centre including a valid purchase note.
If the unit develops a fault during the warranty period, Topcom or its officially appointed service
centre will repair any defects caused by material or manufacturing faults free of charge.
Topcom will at its discretion fulfil its warranty obligations by either repairing or exchanging the
faulty units or parts of the faulty units. In case of replacement, colour and model can be different
from the original purchased unit.
The initial purchase date shall determine the start of the warranty period. The warranty period is
not extended if the unit is exchanged or repaired by Topcom or its appointed service centres.
12.3 WARRANTY EXCLUSIONS
Damage or defects caused by incorrect treatment or operation and damage resulting from use
of non-original parts or accessories not recommended by Topcom are not covered by the
warranty.The warranty does not cover damage caused by outside factors, such as lightning,
water and fire, nor any damage caused during transportation.
No warranty can be claimed if the serial number on the units has been changed, removed or
rendered illegible.
ENGLISH
16TOPCOM HBM Sensor Watch 2002
1EINFÜHRUNG
Wir gratulieren Ihnen zum Kauf der HBM Sensor Watch 2002. Wir hoffen, dass Sie Freude an
der Verwendung des Herzschlagmessgeräts und seinen Vorteilen haben. Bei der Ausübung von
Tätigkeiten oder beim Sporttreiben beginnt Ihr Herz automatisch schneller zu schlagen um das
Blut in Ihrem Körper entsprechend Ihrem gesteigerten Energieniveau zu pumpen. Die
Herzfrequenzmonitoruhr kann diese Steigerung erfassen und in Schlägen pro Minute (bpm)
ausdrücken. Die HBM Sensor Watch hat 5 Benutzermodi:
1.Normaler Zeitmodus
2.Alarmzeitmodus
3.Herzschlagmessung
4.Stoppuhr
5.Countdown-Timer
2SICHERHEITSHINWEISE
Lesen Sie die folgenden Angaben bezüglich Sicherheit und korrekter
Verwendung sorgfältig. Machen Sie sich mit allen Funktionen des
Geräts vertraut. Bewahren Sie diese Gebrauchsanweisung sicher auf.
Vielleicht benötigen Sie sie später nochmals.
Die Verwendung eines Herzüberwachungsgeräts ist KEIN Ersatz für eine professionelle
ärztliche Untersuchung. Wenn Sie an einer Funktionsstörung des Herzens, einer
Herzerkrankung leiden oder erst kürzlich mit einem Fitnesstraining begonnen haben, sollten Sie
einen Arzt aufsuchen oder mit Ihrem Trainer sprechen um einen persönlichen Fitnessplan zu
erarbeiten.
TOPCOM HBM Sensor Watch 200217
Das HBM SW 2002 sollte nur als Hilfsmittel zur Beibehaltung einer sicheren Herzschlagfrequenz
verwendet werden. Es sollte NICHT als medizinische Herzschlagüberwachung verwendet
werden. Wenn Sie unsicher sind, wie Ihr Trainingsprogramm Ihr Herz beeinflussen kann, sollten
Sie sich an einen Arzt wenden.
3PFLEGE UND WARTUNG
Öffnen Sie das Gehäuse oder die Rückseite nicht gewaltsam. Setzen Sie die Uhr KEINEN
extremen Wetterbedingungen oder Reinigungs- oder Lösungsmitteln aus. Vermeiden Sie, dass
die Uhr fällt oder grob behandelt wird. Reinigen Sie die Uhr mit einem trockenen weichen Tuch
oder einem mit Wasser oder einem milden Reinigungszusatz angefeuchteten weichen Tuch.
Bewahren Sie die Uhr an einem trockenen Platz auf, wenn Sie sie nicht benutzen.
4ENTSORGUNG DES GERÄTS (UMWELT)
Am Ende der Lebensdauer des Produkts sollten Sie dieses Produkt nicht in den
normalen Hausmüll werfen, sondern an einer Sammelstelle für die Aufbereitung
von elektrischen und elektronischen Geräten abgeben. Das Symbol am
Produkt, in der Gebrauchsanweisung und/oder auf der Verpackung zeigt das
an.
Einige der Materialien des Produkts können wiederverwertet werden, wenn man sie in einer
Aufbereitungsstelle abgibt. Mit der Wiederverwertung einiger Teile oder Rohmaterialien aus
gebrauchten Produkten liefern Sie einen wichtigen Beitrag zum Umweltschutz. Wenden Sie sich
bitte an Ihre örtlichen Behörden, wenn Sie weitere Informationen über die Sammelpunkte in Ihrer
Umgebung benötigen.
DEUTSCH
18TOPCOM HBM Sensor Watch 2002
5TASTEN
6
1.START/STOPP - Taste (ST./STP.)
5
2.RESET-Taste
4
1
3.MODE-Taste
4.LICHT-Taste
3
5.1 MASTER RESET
Drücken und halten Sie ST./STP., RESET und MODE gleichzeitig um das HBM SW 2002
zurückzustellen.
!!! Alle eingestellten Informationen gehen verloren, auch das Datum und die Uhrzeit.
5.2 HINTERGRUNDBELEUCHTUNG
Drücken Sie kurz LIGHT um die Hintergrundbeleuchtung des Displays zu aktivieren.
2
5.LCD-Display
6.Sensor
TOPCOM HBM Sensor Watch 200219
6BETRIEBSMODI
Das HBM Wirst hat 5 Betriebsmodi
4
3
Der normale Timer-Modus wird angezeigt, wenn innerhalb 1 Minute KEINE Taste
betätigt wird.
5
2b
1
2a
Drücken Sie MODE um durch die
nächsten Betriebsmodi zu scrollen.
1.Aktuelle Zeit
2.Alarmmodus Herzschlagfrequenz
a. Alarm Herzschlagfrequenz AN
b. Alarm Herzschlagfrequenz AUS
3.Täglicher Alarmmodus
4.Stoppuhr
5.Timer-Modus
7ZEIT UND DATUM
Aktuelle Zeit:
• Drücken Sie ST./STP., um das Datum zu selektieren
• Drücken Sie ST./STP., um zur Zeit zurückzuschalten.
Wenn 8 Sekunden lang keine Taste betätigt wird, kehrt das
Gerät automatisch zum Zeit-Modus zurück.
DEUTSCH
20TOPCOM HBM Sensor Watch 2002
7.1 DATUM UND UHRZEIT EINSTELLEN
Aktuelle Zeit:
• Drücken und halten Sie MODE bis die Sekunden im Display blinken.
• Drücken Sie ST./STP., um die Sekunden auf Null zu stellen.
• Drücken Sie MODE um zu Minuten zu schalten.
• Drücken Sie ST./STP., um die Minuten zu erhöhen oder RESET um die Minuten zu verrinern.
• Drücken Sie MODEum zu Stunden zu schalten.
• Gehen Sie wie beim Einstellen der Minuten vor um die Stunden, das Jahr, den Monat und den
Tag einzustellen.
Nach Einstellung des Datums
• Drücken Sie ST./STP., um die Anzeige des Datums zu selektieren (’Monat/Tag’ oder ’Tag/
Monat’).
• Drücken Sie MODEum zur Stundeneinstellung zu schalten.
• Drücken Sie ST./STP., um 24-Stunden-System oder 12-Stunden-System zu selektieren
(Anzeige AM/PM)
TOPCOM HBM Sensor Watch 200221
• Drücken Sie MODE um zur Tastentoneinstellung zu schalten.
• Drücken Sie ST./STP., um den Tastenton an- (ON) oder auszuschalten (OFF).
• Wenn Datum und Zeit eingestellt sind, drücken und halten Sie MODE um die Einstellung zu
bestätigen.
8TÄGLICHER ALARM
8.1 DEN TÄGLICHEN ALARM EINSTELLEN
- Drücken Sie MODE zweimal um zum Alarmmodus zu schalten.
- Drücken und halten Sie MODE bis die Stunden im Display blinken.
- Drücken Sie ST./STP., um die Stunden zu erhöhen oder RESET um die
Stunden zu verringern. Wenn Sie die Stunden geändert haben, ist der
Alarm an und das Symbol für den täglichen Alarm wird angezeigt.
- Drücken Sie MODE um zu Minuten zu schalten.
- Drücken Sie ST./STP. zum Erhöhen der Minuten oder RESET zum Verrin-
gern der Minuten.
- Wenn die Zeit richtig ist, drücken und halten Sie MODE um die Einstellung
zu bestätigen.
DEUTSCH
22TOPCOM HBM Sensor Watch 2002
8.2 DEN ALARM AKTIVIEREN/DEAKTIVIEREN
- Drücken Sie MODE zweimal um zum Alarmmodus zu schalten.
- Drücken Sie ST./STP., um den täglichen Alarm zu aktivieren/deak-
tivieren. Wenn der tägliche Alarm an (ON) ist, wird angezeigt.
- Drücken Sie RESET um das stündliche Klingeln zu aktivieren/deak-
tivieren. Wenn das stündliche Klingeln an ist, wird angezeigt. Die
Uhr piept nun stündlich.
9STOPPUHR
Die maximale Zählzeit ist 99 Stunden, 59 Minuten und 59,99 Sekunden.
- Drücken Sie dreimal MODE um zum Stoppuhrmodus zu schalten.
- Wenn 0:00 angezeigt wird, drücken Sie ST./STP. um mit dem Zählen zu
beginnen.
- Drücken Sie ST./STP., erneut um das Zählen zu beenden.
- Drücken Sie RESET um den Zähler wieder auf 0:00 zurückzustellen.
Loading...
+ 50 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.