3. WIRING
3.1. Connection Diagram
3.2. The Type of Cables
The types of cables are to be determined according to the following conditions.
• Twisted pair wires (such as those used for electronic push­button telephone) are to be used for wiring between the Exchange and the stations in principle.
• Outdoor wires should be used where wiring passes through inaccessible areas such as ceilings or under floors where the maintenance is not performed. Indoor wires may also be used, however, in case where there is no risk of deterioration due to exposure to heat, etc.
Note
Specifications related to each junction are as follows.
Mini-clamp connector (N-8000EX line terminal)
Conductor diameter: ø 0.4 – 0.65 mm (AWG22 – 26),
Solid wire
Outside diameter: ø 1.05 mm or below
Clip terminal (E-7000TB)
Conductor diameter: ø 0.4 – 0.8 mm (AWG20 – 26), Solid
wire
Outside diameter: ø 1.5 mm or below
3.3. Relations Between Core Diameter of Cable and Maximum Cable Length
Referring to the following chart as guidelines, design the distance between the Exchange and stations so that loop resistance value becomes 170 Ω or less.
3.4. Mini-Clamp Connector Connection
Mini-clamp connectors for line terminals are supplied with the N-8000EX Exchange. Connect the mini-clamp connector to a cable using a commercially available tool (pliers).
Step 1. Cut off two-cable ends in equal length, and insert
them securely to a cover section (transparent side) of the mini-clamp connector.
Note
Insert the cable without stripping the cable jacket.
Step 2. With a pair of pliers, lightly pinch the mini-clamp
cover and, after ensuring that the cable is securely inserted, firmly squeeze on the cover.
Note
Squeeze on the mini-clamp cover until it is correctly locked.
Step 3. Insert the wired connector (plug) into the exchange's
connector (socket) until it locks into place.
1. WALL MOUNTING
The station can be mounted on a wall using an optional YC-290 wall mounting bracket. The YC-290 can be installed to JIS standard one gang switch box.
1.1. Mounting Example
Step 1. Install the YC-290 Wall mounting bracket to the wall.
Notes
• Use appropriate screws for the construction of wall.
• Wooden screws 3.5 x 20 are supplied with the YC-290.
• No fitting screws for switch box are supplied.
Step 2. Hang the station on the Wall mounting bracket hook
to install. Push down the station main body in the direction indicated by the arrow.
2. DESK-TOP INSTALLATION
In desktop installations, the front operation panel can be inclined 16˚ from the desk surface for easier operation by attaching the YC-290 Wall Mounting Bracket to its bottom surface.
2.1. Mounting Example
Hang the Wall mounting bracket hook on the station's wall bracket mounting slot to install. Push up the Wall mounting bracket in the direction indicated by the arrow.
This Master Station is designed to connect to the IP Intercom Exchange, and provides hands-free conversation of high sound quality. With its space-saving design, this Master Station features the same functions as the Standard Master Station. Using an optional YC-290 Wall Mounting Bracket, this station can be mounted on a wall, or tilted for easy key operation when used on a desktop.
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
N-8011MS
STANDARD HANDS-FREE MASTER STATION
INSTALLATION MANUAL
To connect the cables from the N-8000EX Exchange to the Master Station, use the supplied connection cable and a commercially available RJ­11 modular jack. These cables have no polarity.
Conductor
diameter
(mm)
ø
0.4
ø
0.5
ø
0.65
ø
0.9
Maximum cable length between the
Exchange and station
(Assuming that the loop resistance is 170 Ω.)
570 m
900 m
1.5 km
2.9 km
Loop
resistance
(Ω/km)
295
187
113
58
133-06-260-5C
URL: http://www.toa.jp/
To N-8000EX Exchange
Station
YC-290 Wall mounting bracket
Wall surface
2
1
Hook
Wooden screw 3.5 x 20 (supplied with the YC-290)
[Installation completion drawing]
Unit: mm
YC-290
YC-290
195
60.7
[YC-290 Dimensional drawing]
Rubber foot mounting position (desk-top application)
2-ø4.5
5037
60
4.5 x 10
4.6 x 6
34
50 64
83.5
23.5
Unit: mm
131.5
Station
YC-290 Wall mounting bracket
Rubber foot
Hook
[Installation completion drawing]
192.3
(supplied with the YC-290)
Unit: mm
16 lines
Mini-clamp connector
E-7000TB Terminal board
(Supplied with the N-8000EX)
Both upper and lower terminals (clip terminals) are internally connected.
RJ-11 modular rosette (commercially available)
Connection cable
(accessory)
Station
Cover (transparent side)
Cable
N-8000EX Rear panel
92
72.1
YC-290
16
90