TOA MP-1216 US User Manual

TOA PROFESSIONAL SOUND SYSTEM
MULTI-CHANNEL MONITOR PANEL
MP-1216
DESCRIPTION
TOA’s MP-1216 Multi-Channel Monitor Panel is an active device featuring aural and visual monitoring of up to sixteen channels for any combination of speaker and line level audio circuits. may be monitored. The unit may be located away from the equipment, allowing remote monitoring of system levels. standard, light gauge audio cable for connection to points in the system to be monitored, whether they are speaker or line level.
The MP-1216 is highly useful for monitoring signal levels in any system with multiple channels of line level feeds and/or amplification. This is particularly true when equipment provides, at best, only clip indicators or where there is a variety of different types of indicators-all calibrated to their own “standard” level. This can present a very confusing
“level picture”, even to trained operators.
A major feature of the MP-1216 is that there is a 12 segment LED meter for EACH input. The meters are active at all times so that all levels can be SIMULTANEOUSLY monitored. The meters are calibrated for 0.3W to 1,200W for 8 ohm speaker circuits and -30dB to +6dB *(ref 0.775V) for line level circuits. Each input is bridging, transformer isolated and can accept signals from high or low impedance speaker or line level circuits.
It requires only
Each input has a separate screw terminal for each type of input. This provides positive, hardwired, reliable connections with no input switches to misadjust or fail. Because of the transformer isolation and high impedance inputs, by connecting one channel to a patch bay jack, any audio signals in the patch bay can be safely monitored—
even mic signals (although usually only at low aural levels).
Each individual input channel can also be aurally monitored through a high quality internal speaker or headphone jack. A front panel selector switch is used to select the channel to be monitored and an output level control adjusts the listening volume. Beneath each channel meter is an indicator to show the channel selected for aural monitoring. The monitor circuit provides up to 3 watts output to the internal speaker. When headphones of 8 ohm or higher impedance are used, the internal speaker is automatically disconnected.
Two MP-1216’s can be linked in a Master/Slave configuration using the optional link cable and the rear panel Link switch to select the operation mode. In this way up to 32 channels can be monitored. The Master unit provides the selection and control of aural monitoring for both the Master and the Slave. When in Slave mode, the unit’s Select switch is disabled and the LED indicator above
the selector switch is extinguished.
* 0dB = +4dBm = 1.23V RMS
FEATURES
1. Simultaneous visual monitoring of up to 16 audio signals with a 12 segment LED meter for each channel.
2. Simultaneous monitoring of 32 channels by linking two MP-1216’s.
3. Each input accepts signals at line level or from any type
of speaker circuit (low or high impedance).
4. Transformer isolated, bridging inputs do not affect
circuits to be monitored.
5. No input switches: A separate screw terminal on each
input for each input type for permanent, reliable connections.
6. Individual aural monitoring of each channel, using an
internal speaker or the headphone jack. Indicator light for channel being monitored.
7. Volume control and selector switch for speaker and
headphone control.
8. Back panel switch for Independent, Master or Slave
operation modes with a front panel indicator showing the selected mode.
9. Master unit controls selection and volume for aural
monitoring of all 32 channels for linked units.
10. Calibrated meters for meaningful, relative signal level indications.
11. Occupies only 2 rack spaces.
SPECIFICATIONS
Model No. INPUT & OUTPUT
Nominal Input Levels
Line level Low impedance speaker High impedance speaker
Maximum Meter Levels
Line level Low impedance speaker High impedance speaker
Maximum Output Level
PANEL FUNCTIONS
Operating Controls (common to both)
Operating Control (link
SW on rear panel)
LED Indicators (per channel)
LED Indicators (common to both)
POWER
Power Requirements Power Consumption
PHYSICAL
Finish Black Dimensions
Weight
STANDARD ACCESSORIES
OPTIONAL ACCESSORY
NOTE: 0dB = 0.775V RMS *Specifications are subject to change without notice.
MP-1216
+4dB, transformer isolated 49V, transformer isolated 70V, transformer isolated
(100V 220/240V AC version)
+10dB 98V (1,200W at 8 ohms) 140V
3W into internal speaker or 10mW into
phones jack
Select switch output Power
Link switch
Meter 12 segment LED
Channel indicator On when selected Ch Select
Power
AC Mains, 50Hz/60Hz 21W (120V AC version)
25W (220/240V AC version) Fuse: 1.0A 120V/0.25A 220/240V
482.6W x 88.4H x 312.7D mm (19W x 3.48H x 12.31D in.)
5.3kg (11.7 lbs.)
Spare fuse: 1 Rack screws [metric] 4
YA-8 Link Cable
Chans 1—16 Speaker/Phone level
On/Off
Inde/Master/Slave
On for Master/lnde modes Off for Slave mode On
Architect’s and Engineer’s Specifications
The device shall be a multi-channel monitor panel to provide visual and aural monitoring of up to 16 channels of any combination of high/low impedance speaker and line level circuits. Two units may be linked for monitoring up to 32 channels. Nominal output level shall be 3W into the built-in monitor speaker and a headphone jack for 8 ohm or higher impedance headphones. Rated input levels shall be 70V, 120V AC version (100V, 220/240V AC version) for high impedance speakers, 50V (300W 8 ohms) for low impedance speakers and 1.23V (+4dB) for line level. Maximum input levels for full meter reading are 100V for speaker and 2.5V (+l0dB) for line inputs. All inputs shall be bridging, balanced and transformer isolated.
The front panel shall have a PHONES jack and internal monitor speaker. Front panel controls and switches shall include: POWER On/Off switch; OUTPUT level control and CHAN SELECT switch for the speaker/ headphone monitoring. Front panel indicators for each channel shall include: a Channel Select LED below each meter to indicate the channel being aurally monitored; a 12-point LED meter that shall be active at all times and calibrated for 0.3W to 1200W at 8 ohms and -30dB to +6dB* for line level signals. Also provided shall be a CHAN SELECT switch indicator (On = switch enabled in INDEPENDENT or MASTER modes, Off = switch disabled in SLAVE mode): a POWER On indicator.
The rear panel shall have a switch for setting the mode of operation to INDE, MASTER or SLAVE. INDEPENDENT mode shall be for stand alone operation: MASTER and SLAVE modes for linking two units. In this case one unit shall be in MASTER mode, the other in SLAVE mode. The unit in MASTER mode shall provide the aural monitoring facilities and control of monitor Channel Selection and Level for both units.
The rear panel shall also include: four barrier strip type screw terminals per channel (70V/100V, 8 ohm, 1.23V, Com), with protective plastic covers to prevent accidental shorts; a fuse holder with a replaceable 1 amp (1/4 amp 220/240V) fuse with 1 spare fuse provided.
Power consumption shall be 21 watts at 120V AC (25W 220/240V AC version). The unit shall be enclosed in a durable, black painted 1.0mm (.04 in.) steel enclosure, mechanically reinforced by a 2.0mm (0.08 in.) thick, black Alumirite front panel. Overall dimensions shall be 482.6W x
88.4H x 312.7D mm (19W x 3.48H x 12.31D in.). Weight shall be 5.3kg (11.7 Ibs.). Standard E.I.A. equipment rack mounting shall be provided.
The multi-channel monitor panel shall be the TOA MP-1216.
NOTE: 0dB = 0.775V RMS * 0dB = +4dBm = 1.23V RMS
DIMENSIONAL DIAGRAM
Unit mm(in.)
REAR VIEW
TOA Corporation
Printed in Japan (311 I) 833-64-111-70
Loading...