TJERNLUND SANTEK ELECTRONIC AIR CLEANERS 8500001 REV. B 0905, SANTEK SD-1000, SANTEK SX-2000, SANTEK SP-1200 User Manual

Page 1
SANTEK
Electronic Air
Cleaners
The effective way
to control indoor
air quality
TTJJEERRNNLLUUNNDD
Page 2
Indoor air quality affects everyone
We spend up to 90% of our time indoors and are surrounded by natural and man-made pollutants that threaten our comfort and health. Tighter constructed buildings seal out weather, but also seal in pollutants such as pollen, tobacco and cooking smoke, dust, mites, dander, spores, virus­es and off-gassing from building materials and furnishings.
Electronic air cleaning is a wise investment
Controlling indoor air quality has many health and financial related benefits including:
Healthier employees
Higher productivity
Happier customers
Reduced cleaning of office equipment and
facilities
Lower facility heating and equipment maintenance costs
Santek Electronic Air Cleaners
provide a breath of fresh air
There’s a model to fit your requirements
Efficiency
Air Flow
Capacity
Collecting
Cells
Filters
Blower Speed
Motor Specs
Power
Control
Panel
Physical
Description
Finish
Up to 95% clean air in a 12,000 cubic ft space at 5 air changes/hour. (ACH)
Up to 1,000 cubic feet per minute (CFM) 1 ionizing collecting cell made of
heavy duty .040” aluminum for long life
1 aluminum mesh prefilter; 1 activated charcoal for odor control
3-speed 500/750/1000 CFM,
2.92 Amps,1085 RPM, PSC
115 V,60 Hz, 350 Watts,Solid state 6,000 VDC power supply,6’ power cord
LED indicator light shows proper operation
70 lbs.ship,Ceiling or Wall mount options.13”H,22 1/4”W,16 1/2”D
16 gauge steel black finish
SD-1000 SX-2000 SP-1200
Up to 95% clean air in a 24,000 cubic ft space at 5 air changes/hour. (ACH)
Up to 2,000 cubic feet per minute (CFM) 2 ionizing collecting cells made of
heavy duty .040aluminum for long life
2 aluminum mesh prefilter; 2 activated charcoal for odor control
3-speed 1000/1500/2000 CFM, 2 @ 2.92 Amps, 1085 RPM, PSC
115 V,60 Hz, 650 Watts,Solid state 6,000 VDC power supply,6 power cord
LED indicator light shows proper operation
120 lbs.ship,Ceiling mount. 14H, 24W,32 1/4D
16 gauge steel black finish
Up to 95% clean air in a 14,400 cubic ft space at 5 air changes/hour. (ACH)
Up to 1,200 cubic feet per minute (CFM) 2 ionizing collecting cells made of
heavy duty .040aluminum for long life
1 polyester 22% efficient prefilter; 2 activated charcoal for odor control
Variable speed 500-1200 CFM, 2 Amps
115 V,60 Hz, 240 Watts,solid state 6,000 VDC power supply,6 power cord
LED indicator light shows proper operation
110 lbs.ship,Flush in Ceiling mount.9 1/2H, 22 3/4W,46 3/4”L
18 gauge off white textured
Page 3
5% 90% 5%
Wood Smoke
Cooking/Grease Smoke
Oil Smoke
Smog
Household Dust
Animal Dander
Lint
Metallurgical Dust & Fumes Pollen Plant Spores
Fungi Spores
Bacteria
Viruses
Tobacco Smoke
100 10 1.0 0.5 0.1 0.01 0.001
% of Airbourne Particles
Smoke
and
Smog
Dust
Living
Airbourne
Organisms
Particle
size in
Microns
Visible
with
Naked Eye
Visible
with Light
Microscope
Visible
with Electron
Microscope
Santek electronic air cleaners remove particles 88,000
times smaller than the period at the end of this sentence.
Standard air filters clean only a small percentage of the air we breathe. Smoke, dust, pollen, bacteria and other contaminants flow through and are recirculated into the air. Using a 4-stage filtra­tion process, Santek electronic air cleaners remove up to 95% of all contaminates.
4-stage filtration removes dust, smoke
and odors that standard filters can’t
Stage 1:
Aluminum mesh or polyester pre­filter removes larger particles to reduce electronic collecting cell maintenance and to extend life of activated charcoal filter.
Stage 2:
Remaining particles go through ionizing section where they receive an electrical charge.
Stage 3:
Collecting cells with oppositely charged electronic plates attract and collect charged particles like a high powered electromagnet.
Stage 4:
Activated charcoal filter adsorbs most of the remaining particles, removing resid­ual odors before finally recirculating 95% cleaner air back into interior space.
Some things you’re probably glad you dont see every day!
Dust Mite & Debris
.5 to 60 microns
Pollen
3 to 100 microns
Bacteria
.1 to 30 microns
Airborne Particle Removal Efficiency Chart
95% Efficient Santek Electronic Air Cleaner
Filters
Standard
Filter
Page 4
Odors
Dust
Cigarette &
Cooking Smoke
Viruses &
Bacteria
Applications
Restaurants/Bars
Bingo Halls
Printing/Photo
Finishing
Beauty Parlors/
Salons
Offices
Daycare/
Classrooms
Retail Stores/
Showrooms
Pet Stores/
Vet Clinics
Health Clubs/
Locker Rooms
Computer
Rooms
Medical/
Dental Labs
Typical applications where Santek
Air Cleaners help clear the air of
common pollutants
Santek Air Cleaner Sizing
The first step in selecting the proper Santek air cleaner is to deter­mine the volume of air that needs to be filtered.Volume is deter­mined by multiplying the length x width x height to arrive at cubic feet.The cubic footage is divided by 60 to arrive at the CFM (Cubic feet per minute) necessary for one complete air cleaning per hour. The final step is to multiply the CFM value by the recommended number of air cleanings per hour to arrive at the total CFM neces­sary to properly clean the air in the establishment.
Example:
Conference room measuring 20' x 25' with an 8' ceiling. (20 x 25 x 8)
x 8 Desired Air Cleanings per hour = 533 CFM
60 The selected air cleaner would need a minimum capacity of at least 533 CFM to clean the room 8 times per hour.
Examples of guidelines for recommended air changes per hour:
Recommended
Common Pollutant Air Changes Applications Concentration Per Hour
Homes & Offices Average 5-7 Restaurants & Mtg. Rooms Above Average 8-10 Bars & Smoking Areas Heavy 10-12
A Proper maintenance schedule is a must
Regular cleanings of prefilter screen and collecting cells are necessary for proper operation. In installa­tions where there is a high level of pollutants like cigarette smoke, cleanings should be more frequent. A non-alkaline based detergent or cleaning solution should be used to properly clean cells for extended life and peak efficiency. Santek has manufactured electronic air cleaners for over 30 years and many early models are still operating under peak efficiency with proper maintenance.
Accessory items also available
Prefilters should be cleaned or replaced and activated charcoal filters should be replaced on a regular basis for consistent odor removal. Santek activated charcoal filters are matched with Santek air cleaners to deliver optimum performance and fresh air.
Ceiling or wall mount kits also available.
TJE RNL U N D PROD U CTS, INC.
1601 Ninth Street White Bear Lake, MN 55110-6794 Phone: 651.426.2993 800.255.4208 Fax: 651.426.9547 Visit our web site: www.tjernlund.com
Copyright © 2005 Tjernlund Products, Inc. All rights reserved P/N 8500001 Rev.B 09/05
Assistance is just a phone call away
For complete application information or assistance in sizing the proper Santek Air Cleaner for your application, call Tjernlund Products at 1-800-255-4208 or visit our web site at www.tjernlund.com.
Distributed by:
Loading...