Tjernlund P Series User Manual

Do not connect power supply until the fan is completely installed. Disconnect power to fan prior to service or maintenance.
1. This unit has rotating parts. Safety precautions should be exercised during installation, operation and maintenance.
2. Do not
use these fans in hazardous environments where the fan’s electrical system could provide ignition to combustible or
flammable materials.
3. Turn centrifugal impeller by hand to make sure it rotates freely. If the impeller does not rotate freely contact Tjernlund’s customer service department at 800-255-4208.
4. Ducted fans used for exhaust applications must always be vented to the outdoors.
Use To Exhaust Hazardous Or Explosive Materials And Vapors.”
6. Rated for air stream temperatures from 32°F (0°C) to 140°F (60°C).
IMPORTANT: All wiring must be in accordance with the National Electrical Code. Verify supply voltage and power consumption of fan are suitable for circuit fan will be added to.
GUARDS OR DUCTING ON INLET/OUTLET OF FAN MUST BE INSTALLED WHEN THE FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN (7) FEET OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY.
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547 Visit our web site • www.tjernlund.com
READ OWNERS INSTRUCTIONS
CAREFULLY PRIOR TO
INSTALLATION. DO NOT DESTROY.
P-Series
Plastic High Pressure In-Line Duct Booster® Fans
©2014 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED. P/N: 8504158 REV A
Models
P-4 P-6 P-8
TJERNLUND LIMITED 1 YEAR WARRANTY
Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PROD­UCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIM­ITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. Send all inquiries regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 • Email fanmail@tjfans.com.
SPECIFICATIONS
Model
Inlet / Outlet
Diam.
Volts Watts Amps Free Air CFM (0” w.c.)
P-4 4” 120 80 0.70 190
P-6 6” 120 131 1.15 400
P-8 8” 120 175 1.75 675
Motors have Class B Thermal protection.
WARNING
!
INSTALLATION INSTRUCTIONS
NOTE: Electrical cord is 4.5 feet.
1. Cut and adhere foam gasket on inlet and outlet collars of fan, (See Diagram A).
2. Make sure fan is mounted with air flow direction arrow pointing in the right direction. The air flow exits opposite motor side, (See Diagram B).
3. Fasten mounting bracket against a solid surface with proper orientation and air flow direction in mind, (See Diagram C).
WIRING DIAGRAM
Connection with Flex Duct
Use Nylon Ties and Over-Wrap
with Duct Tape
Use Sheet Metal Screws (1” Max) and
Over-Wrap with Duct Tape
Encircle with Perforated Plumber’s
Strap and Secure Tightly
Mounting with Perforated Strap
Connection with Rigid Duct
DIAGRAM B DIAGRAM C
DIAGRAM A
Rotation / Air Flow Arrows
Motor
Air Flow
MODEL SCP SPEED CONTROL
The optional SCP Speed Control is a convenient and easy way to vary the speed of the P-Series fans. The SCP is fac­tory calibrated for use with Tjernlund’s M & P series high pressure fans. Plug fan into speed control and plug speed control into 115 VAC outlet.
INTERNAL WIRING
If it is necessary to hard-wire fan, remove power cord and follow diagram below. IMPORTANT: All wiring must be in accordance with the National Electrical Code. Verify sup­ply voltage and power consumption of fan are suitable for circuit fan is wired to.
(OPTIONAL PS1503 DUCT AIRSTAT SWITCH)
The Tjernlund PS1503 Duct Airstat is used to automatically activate Duct Booster® fans by sensing positive pressure in a forced air heating and/or cooling system.The single pole, single throw, snap-acting switch is activated by a diaphragm with a factory installed sampling probe inserted directly into the duct or plenum.