TJERNLUND aireshare as1p, AIRESHARE R2RP User Manual

DESCRIPTION
The Tjernlund AireShare™ Room-to-Room Ventilators distribute air from one space to another. Virtually every home has a room that is uncomfortably hot or cold from which some of that room’s air can be shared with an adjacent room, making the temperature of both rooms more comfortable. The AireShare™ transfers air through the wall cavity created between two wall studs. The AireShare’s unique option of moving the air up or down within the wall cavity allows for optimum heat transfer between rooms – a typical application will affect the temperature 3° F per hour. In addition, locating the Grille and Diffuser, one high the other low, prevents the transfer of light and sound between these adjacent rooms.
SPECIFICATIONS & COMPONENTS
Every Tjernlund AireShare™ Room-to-Room Ventilator is electrically factory line tested before shipment. After opening carton, inspect thoroughly for shipping damage. Impeller should rotate freely and all electrical wires and connections
should be secured. If any damage is found, notify freight carrier and your distributor immediately and file a concealed damage claim.
INSTALLATION RESTRICTIONS
The AireShare™ Ventilator must be installed by a qualified installer in accordance with these instructions and all local codes or in their absence in accordance with the latest editions of the International Residential Code and International Electrical Code. Improper installa­tion can create a hazardous condition such as fire, electric shock or personal injury. To reduce these risks significantly, use this device only in the manner intended by the manufacturer. If you have questions about proper usage of this device, call Tjernlund Products.
Always disconnect the AireShare™ Ventilator from its power source before installation and servicing. IMPORTANT: An in depth investigation of the wall layout is required prior to installation. Avoid a stud wall section that is a path for
plumbing supply lines, drains and vents. Avoid a stud wall section that is insulated or being used as a return air duct for a forced air system. If stud walls are constructed with metal studs the Diffuser must be mounted within 3” of the Blower opening since metal studs typical­ly are not solid throughout. If diffuser is not mounted within 3” of Blower any metal stud openings must be plugged or sealed.
READ OWNERS INSTRUCTIONS CARE-
FULLY PRIOR TO INSTALLATION.
THESE INSTRUCTIONS MUST REMAIN
WITH EQUIPMENT. DO NOT DESTROY.
AIRESHARETMROOM-TO-ROOM VENTILATOR
MODEL AS1P
MODEL AS1P
Blower: 75 cfm Motor: 115 Volts ~ 60 Hz
0.50 amps maximum Impeller: Transtangental, cross-flow Dimensions:
Diffuser: 3” x 15 1/8” (flush) Diffuser Rough Opening: 1 1/4” Height x 13 5/8” Width Blower Grille: 7 3/4” x 15 7/8” x 1 1/4” Blower Rough Opening: 4 7/8” Height x 12” Width
Color: Neutral White Power Cord: 12” long, grounded On/Off Switch: 120 Volts; rated to 100,000 cycles
©2008 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED P/N: 8504137 Rev A 02/08
The AireShare™ may not be used to exhaust hazardous or explosive materials or vapors.
• The AireShare™ may not be installed in a ceiling.
• The AireShare™ may not be installed in an outside wall.
• The AireShare™ may not be installed in a wall rated as a “fire wall.”
• The AireShare™ may not be used to move air from one floor (story) to another floor.
• The AireShare™ may not be used to move moisture-laden air from sources such as bathrooms and kitchens.
• The AireShare™ may not be used in a window. WARNING: To reduce the risk of fire, electrical shock and injury to persons, the
AireShare™ must be installed with the AS1P Diffuser that was provided with the AS1P. Do not use this product without the AS1P Diffuser or with any Diffuser other than the AS1P Diffuser.
WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control devices.
Disrupt power at circuit breaker to outlets within the stud wall you will be working.
When sawing through sheetrock you must stop if you detect the saw blade coming in contact with any wiring or plumbing. Investigate further to determine if it is possible to safely continue to use this wall cavity space. Switch to another stud wall cavity if necessary.
BEFORE YOU START:
Determine the stud wall section that you want to use to mount the Blower and Diffuser. You must
select a stud wall section that contains an electrical outlet, (See Diagram A). IMPORTANT: Wall studs must be spaced a minimum of 16” o.c., (See Diagram B). Mark inside edges of studs the Aireshare
TM
will be installed between and verify there is at least 14” between the inside edges. Slide a stud finder down the wall between the studs to verify the stud wall cavity is completely open, (See Diagram C).
TOOLS REQUIRED
Sheetrock Saw Philips & Straight Screwdrivers Level Tape Measure Utility Knife or Scissors
INSTALLING DISCHARGE DIFFUSER
IMPORTANT: Install Diffuser first if mounting the Blower down low and the Diffuser high so sheetrock from the
Diffuser cut out does not fall into wall cavity and damage Blower. Install the Blower first if mounting the Blower high and Diffuser low so sheetrock from the Blower cut out does not fall into wall cavity and damage Diffuser.
NOTE: Since electrical outlets are usually not up high, typical installations of the model AS1P will have the Diffuser
high and the Blower low, but there may be instances where it is desireable to have the Blower mounted high and the Diffuser low to take air from the ceiling level.
1.The Diffuser may be mounted as close as 3" above the top of Blower cut out opening or as close as 3" to the ceiling.
2. Level and mark a line between studs for top of the Diffuser cut out, (See Diagram D)
3. Using a hand sheetrock saw carefully make a horizontal cut along the line. Cut the sheetrock completely until you
come in contact with the opposite stud. NOTE: If studs are spaced greater than 16” o.c., the horizontal cut line should not exceed 14”, (See Diagram E).
DIAGRAM B
Wall studs must be spaced a minimum
of 16” o.c.
IMPORTANT:
Wall cavity between studs must be com­pletely open between Blower Intake and Diffuser
WALL STUD OUTLET
AIRESHARE
AIRESHARE
WALL STUD
ELECTRICAL
WRONG
CORRECT
ELECTRICAL OUTLET SIDE OF THE WALL STUD.
THE AIRESHARE MUST BE LOCATED ON THE
CORRECT
WRONG
AIRESHARE
AIRESHARE
WALL STUD
DIAGRAM A
DIAGRAM D
DIAGRAM E
LEVEL AND MARK A LINE BETWEEN STUDS WHERE DIFFUSER IS TO BE INSTALLED.
CAREFULLY MAKE A LEVEL HORIZONTAL CUT IN SHEET­ROCK BETWEEN STUDS NO LONGER THAN 14”.
DIAGRAM C
Wall studs must
be spaced a
minimum
of 16” o.c.
BLOWER OPENING
DIFFUSER
IMPORTANT: Wall cavity between studs must be com­pletely open between Blower intake and Diffuser
Electrical box must
be installed inside
stud wall section