TJERNLUND 950-8302 T-STAT KIT 8504132 User Manual

(950-8302) CRAWL SPACE VENTILATOR T-STAT REPLACEMENT KIT
Disconnect power or unplug 115 VAC power cord before servicing the Crawl Space Ventilator.
1. Remove Crawl Space Ventilator from wall. IMPORTANT: Note set- ting of dehumidistat (if equipped) so it can be reset when finished. Remove BLACK T-stat leads.
2. Use caution and drill out (2) T-stat rivets from exterior mounting plate with a 5/32” drill bit, (See Diagram A).
4. Reinstall Crawl Space Ventilator in opening.
5. Reestablish 115 VAC power and cycle Crawl Space Ventilator “on” to verify proper operation. Reset dehumidistat (if equipped). NOTE: If outside temperature is below 50
o
F, T-stat may not allow Ventilator to turn on.
Rev. 10/06 Copyright © 2006, Tjernlund Products, Inc. All rights reserved. P/N 8504132
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547 Visit our web site • www.tjernlund.com
EXTERIOR VIEW
Model V1 Shown
Drill out (2) T-stat rivets on exterior mounting plate with 5/32” drill bit.
DIAGRAM A